This is a
1.Put the Z-Wave Controller into inclusion mode.2.Press the link key three times within 1.5 seconds to put the unit into inclusion mode.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The AN184 is a miniature size on/off and metering plug to control lighting and appliances. It is possible to turn on/off home devices and check the status directly from a smartphone.Compact in design, yet certified for safety by makes it suitable for plugging into any power outlet. The metering plug can support wattage, voltage, ampere, and measurement. The unit can also detect overload upon which the unit will switch off relay and keep LED flashing until power is off and re-applied.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
1.Press the link key three times within 1.5 seconds to put the unit into exclusion mode.2.Within 1 second of step 1, press link key again and hold it until LED is off (about 5 seconds).3.Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 25 secs.(Use this procedure only in the event that the network primary controller is missing, or otherwise inoperable.)
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Z-Wave Plus Lifeline |
2 | 4 | On/Off Control |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Value can be set 0~99, 255 Size: 2 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 99 | Basic Set Command value |
255 | 0xFF |
Value can be set 3~25 seconds Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
3 - 25 | Delaying time to report to Group 1 |
Value can be set 1 or 0 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | Remember or not remember the last status |
Value can be set 1~32767 minutes Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 32767 | The interval for wattage auto report |
Value can be set 1~32767 minutes Size: 2 Byte, Default Value: 60
Setting | Description |
---|---|
1 - 32767 | The interval for kW*h auto report |
Value can be set 0~3500W Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 3500 | 0: does not report automatically |
Value can be set 0~100% Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 100 | 0: does not report automatically |
Hardware Platform | SD3502 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00:00.04 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-18106278 |
Z-Wave Product Id | 0x0060.0x0004.0x000B |
Supported Meter Type | Electric Energy |
Color | White |
Supported Notification Types | Power Management |
Firmware Updatable | Updatable by Consumer by RF |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |