Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
- Click [Add] icon in Z-Wave Controller .- Press the Func_Button 3 times within 1.5s, Green LED is Blinking 4 times within 1 second.- If Inclusion Process is successful, Green led will turn off.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

When the gateway is in the armed state, once the motion sensor detects the movement of a person, it will send alarm signals to gateway, and the gateway will send the alarm signal to mobile phone App immediately.

Reset to factory default Long press Func_Button while installing batteries in the Device -Device Reset Locally notification is Transmitted-Green LED Turns off after 2 seconds.Please use this procedure only when the network primary controller is missing or otherwiseinoperable.
Inclusion - Click [Add] icon in Z-Wave Controller .- Press the Func_Button 3 times within 1.5s, Green LED is Blinking 4 times within 1 second.- If Inclusion Process is successful, Green led will turn off.
Exclusion - Click [Remove] icon in Z-Wave Controller- Press the Func_Button 3 times within 1.5s - If Exclusion Process is successful, Green led is Blinking 6 times, then turn off.
NIF XXXNIF
Wakeup -Wake up Notification is transmitted every 300s by default.-Wake up Notification is transmitted after Notification Report is Transmitted
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Lifeline association group
2 5 Root device group

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 255 FW: 3.01
Z-Wave Version 6.71.03
Certification ID ZC10-18106273
Z-Wave Product Id 0x0260.0x8001.0x1001
Color White
Supported Notification Types Access ControlEmergency AlarmHome Security
Sensors
Communications Protocol Z-Wave Serial API
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor