Quickstart

This is a secure Door Lock - Keypad for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Enter the 4-8 master Pin code followed by the gear key.Press the 7 key followed by the gear keyPress the 1 key followed by the gear key



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Replace your existing lever or knob with the Assure Lever, a touchscreen lever lock, and enjoy the convenience of unlocking and locking your door using the backlit touchscreen keypad; you'll never have to carry around your keys again. Create unique entry codes for friends and family and remove codes whenever you need to. Great for side entry doors, garage entry, basement doors, home offices - any door with a single hole prep. The lock is Grade 2 certified and backed Yale, one of the world's best known brands in the lock industry that's been securing homes since 1840, ensuring that your home and family is always safe. The Assure Lever features Z-Wave technology and seamlessly integrates into compatible home automation and alarm systems. When added to most Z-Wave automation systems, lock and unlock your door, create pin codes, view access history and receive notifications from anywhere. Easy to install and even easier to use! *Features may vary based on Z-Wave controller.

Reset to factory default Remove the battery cover and batteries.Remove the interior escutcheon to access the reset button.The reset button is located above the PCB cable connector.While pressing the reset button for a minimum of 3 seconds, reinstall batteries. Release reset button.Replace battery cover. Please use this procedure only when the network primary controller is missing or otherwise inoperable
Inclusion Enter the 4-8 master Pin code followed by the gear key.Press the 7 key followed by the gear keyPress the 1 key followed by the gear key
Exclusion Enter the 4-8 digit master pin code followed by the gear keyPress the 7 key followed by the gear keyPress the 3 key followed by the gear key
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Silent Mode on/off

Level control, 1, 2, 3 default is 2. Levels are 1 and 3 for models with no spoken prompts default is 1 or high
Size: 1 Byte, Default Value: 2

Setting Description
1 - 3 Sound level

Parameter 11: One Touch Locking

0x00 = OFF, 0xFF = ON default is 0xFF or ON.
Size: 1 Byte, Default Value: 0

Setting Description
-128 One Touch Locking On
0 One Touch Locking Off

Parameter 13: Lock Status LED

0x00 = OFF , 0xFF=ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
-128 Lock Status LED On
0 Lock Status LED Off

Parameter 15: Reset to Factory Defaults

01 = Lock will execute Reset To Factory.02 = Reserved for future use (Lock will currently execute Reset To Factory same as 01). No default valuePlease use this procedure only when the network primary controller is missing or otherwise inoperable.
Size: 1 Byte, Default Value: 0

Setting Description
-128 Reset to Factory ON
0 Reset to Factory Off

Parameter 2: Auto Relock on/off

0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
-128 Auto Relock On
0 Auto Relock OFF

Parameter 3: Relock Time

10 to 127 seconds default is 30 seconds
Size: 1 Byte, Default Value: 30

Setting Description
10 - 127 Seconds

Parameter 4: Wrong Code Entry Limit

3 to 10 default is 5 times
Size: 1 Byte, Default Value: 5

Setting Description
3 - 10 Times

Parameter 5: Language

1=English, 2=Spanish, 3=French default is 1= English
Size: 1 Byte, Default Value: 1

Setting Description
1 English
2 Spanish
3 French

Parameter 7: Shut Down Time (After wrong codes)

10 to 127 seconds default is 60 seconds
Size: 1 Byte, Default Value: 60

Setting Description
10 - 127 Seconds

Parameter 8: Operating Mode

00 = normal mode (this is the default mode)01 = vacation mode, keypad lockout02 = privacy mode, no keypad. RF Unlock will work
Size: 1 Byte, Default Value: 0

Setting Description
0 Normal Mode
1 Vacation Mode
2 Privacy Mode

Technical Data

Hardware Platform ZM5101
Device Type Door Lock - Keypad
Network Operation Listening Sleeping Slave
Firmware Version HW: 255 FW: 1.78:28.00
Z-Wave Version 6.51.07
Certification ID ZC10-18106272
Z-Wave Product Id 0x0129.0x800C.0x0F00
Firmware Updatable Updatable by Consumer by RF
IP (Ingress Protection) Rated ok
Outdoor Use ok
Sensors Open/Closed (Binary)
Supported Notification Types Access Control
Door Lock Type Lever Handle
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoDoor Lock - Keypad