Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Aeotec Smart Switch 6 is a low-cost Z-Wave Switch plug-in module specifically used to enable Z-Wave command and control (on/off) of any plug-in tool. It can report immediate wattage consumption or kWh energy usage over a period of time. In the event of power failure, non-volatile memory retains all programmed information relating to the units operating status.Its surface has a Smart RGB LED, which can be used for indicating the output load status or strength of the wireless signal. You can configure its indication colour according to your favour.The Smart Switch is also a security Z-Wave device and supports Over The Air (OTA) feature for the products firmware upgrade.

Reset to factory default Press and hold the Action button that you can find on the product's housing for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action button that you can find on the product's housing.
Exclusion Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action button that you can find on the product's housing.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline.The Hial CC and Basic Report CC (configured by parameter 80) can be sent to the associatd nodes in this group.
2 5 Forward the Basic Set, Switch Binary Set to associated nodes in Group 2 when the Plug receives the Basic Set, Switch Binary Set commands from the main controller.

Configuration Parameters

Parameter 101: To set which report would be sent in Report group 1

To set which report would be sent in Report group 1
Size: 4 Byte, Default Value: 0

Setting Description
1 Send Meter Report of Voltage
2 Send Meter Report of Current
4 Send Meter Report of Watt
8 Send Meter Report of kWh

Parameter 102: To set which report would be sent in Report group 2

To set which report would be sent in Report group 2
Size: 4 Byte, Default Value: 0

Setting Description
1 Send Meter Report of Voltage
2 Send Meter Report of Current
4 Send Meter Report of Watt
8 Send Meter Report of kWh

Parameter 103: To set which report would be sent in Report group 3

To set which report would be sent in Report group 3
Size: 4 Byte, Default Value: 0

Setting Description
1 Send Meter Report of Voltage
2 Send Meter Report of Current
4 Send Meter Report of Watt
8 Send Meter Report of kWh

Parameter 111: Set the time interval of sending Report

Set the time interval of sending Report
Size: 4 Byte, Default Value: 3

Setting Description
1 - 2147483647 Interval Seconds

Parameter 112: Set the time interval of sending Report

Set the time interval of sending Report
Size: 4 Byte, Default Value: 600

Setting Description
1 - 2147483647 Interval Seconds

Parameter 113: Set the time interval of sending Report

Set the time interval of sending Report
Size: 4 Byte, Default Value: 600

Setting Description
1 - 2147483647 Interval Seconds

Parameter 20: Configure the output load status after re-power on

Configure the output load status after re-power on
Size: 1 Byte, Default Value: 0

Setting Description
0 The last status before the power outage.
1 Always on
2 Always off

Parameter 200: PartnerID

PartnerID
Size: 1 Byte, Default Value: 0

Setting Description
0 Aeon Labs Standard Product
1 - 127 Others

Parameter 252: Enable/disable Configuration Locked

Enable/disable Configuration Locked
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 254: Device Tag

Device Tag
Size: 2 Byte, Default Value: 0

Setting Description
0 - 127 Device Tag

Parameter 255: Reset the Smart Switch

Reset the Smart Switch to factory default.
Size: 1 Byte, Default Value: 0

Setting Description
0 Energy mode. The LED will follow the status (on/off).
1 Momentary indicate mode. When the state of Switchs load changed, The LED will follow the status (on/off) of its load, but the LED will turn off after 5 seconds if there is no any switch action.
2 Night light mode. The LED will remain the state that is set via the Multilevel Switch Set CC or Color Switch Set CC.
1 Reset all configuration parameters to default.
1431655765 Reset the Smart Switch to factory default

Parameter 3: Current Overload Protection.

Current Overload Protection. Output load will be closed after 2 minutes if the current overruns (US: 16.5A, AU: 10.5A, EU: 14A).
Size: 1 Byte, Default Value: 1

Setting Description
0 Disabled
1 Enabled

Parameter 33: Set the RGB LEDs color for testing.

Set the RGB LEDs color for testing.
Size: 4 Byte, Default Value: 0

Setting Description
0 - 255 Blue color value
256 - 65535 Green color value
65536 - 16711680 Red color value

Parameter 65: To set which report would be sent in Report group 1

To set which report would be sent in Report group 1
Size: 4 Byte, Default Value: 0

Setting Description
1 Send Meter Report of Voltage
2 Send Meter Report of Current
4 Send Meter Report of Watt
8 Send Meter Report of kWh

Parameter 66: To set which report would be sent in Report group 2

To set which report would be sent in Report group 2
Size: 4 Byte, Default Value: 0

Setting Description
1 Send Meter Report of Voltage
2 Send Meter Report of Current
4 Send Meter Report of Watt
8 Send Meter Report of kWh

Parameter 80: To set which notification would be sent to the associated nodes in association group 1

To set which notification would be sent to the associated nodes in association group 1 when the state of output load is changed.
Size: 1 Byte, Default Value: 0

Setting Description
0 Nothing
1 Hail CC
2 Basic Report CC

Parameter 83: Configure the RGB value

Configure the RGB value when it is in Night light mode.
Size: 4 Byte, Default Value: 1774619

Setting Description
0 - 255 Blue color value
256 - 65535 Green color value
65536 - 16711680 Red color value

Parameter 84: Configure the brightness level of RGB LED

Configure the brightness level of RGB LED (0%-100%) when it is in Energy Mode/Momentary indicate mode.
Size: 4 Byte, Default Value: 3289650

Setting Description
0 - 100 The brightness of Red color
256 - 356 The brightness of Yellow color
65536 - 65636 The brightness of Green color

Parameter 90: Enable/disable the parameter 91 and 92

Enable/disable the parameter 91 and 92.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 91: Induce an automatic report

The value here represents minimum change in wattage (in terms of wattage) to induce a Meter Report
Size: 2 Byte, Default Value: 25

Setting Description
0 - 32767 The threshold can be set from 0 to 32767 watt.

Parameter 92: Induce an automatic report

The value here represents minimum change in wattage percent (in terms of percentage) to induce a Meter Report
Size: 1 Byte, Default Value: 5

Setting Description
0 - 100 The threshold can be set from 0 to 100%.

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 96 FW: 1.04
Z-Wave Version 6.51.10
Certification ID ZC10-18106250
Z-Wave Product Id 0x0086.0x0103.0x0060
Supported Meter Type Electric Energy
Firmware Updatable Updatable by Consumer by RF
Electric Load Type Dimmable LEDELV (Electronic)FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic)
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoOn/Off Power Switch