Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Inclusion: Add the device into your network by a Z-Wave certied controller. If the controller is SmartStart compatible, refer to the controller manufacturer app that allows the DSK code to be scanned, and scan the DSK code on the inside of the battery door or on the box. If your controller is not S2/ SmartStart compatible, the device can be added using the traditional method for Z-Wave as follows:1. Place your controller into Inclusion (Add) mode by following the controller manufacturer's instructions.2. When the controller is ready, single click the button of LD-100. The controller should indicate that the new device was added successfully. If the controller shows it failed, repeat the procedure.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

ZL-LD-100 is designed to detect and alert any water leaks in residential or commercial buildings. ZL-LD-100 features an audible buzzer in addition to a wireless alert to your controller providing early notification of water leaks before major damage occurs. - Water sensing cable may be placed anywhere where there is a risk of a leak, horizontal (oor, attic) or vertical (wall, along pipes), providing 3D capability to sense the leak.- Senses as little as couple of drops of water (0.25ml0.5ml)- Provides hundreds of times more coverage vs. traditional single point sensors that only detect leaks in a very localized area.- Quickly senses water leaks (every 400msec with micro USB power supply, every 60 sec. with battery) before expensive damage occurs.- LD-100 reports local temperature once every 60 minutes on battery, when using micro USB power supply it can be set using conguration parameter 3.- Built-in audible buzzer sounds when water is detected.- Includes 4-foot-long sensing cable that senses water on any part of the cable.- Water sensing cable extend-able up to 150 feet with available extensions.- Powered by 3 x AAA batteries (not included) or standard 5V micro USB power supply (not included).

Reset to factory default Use the manual reset procedure only in the event that the network primary controller is lost or otherwise inoperable.Press and hold the Z-Wave button on the sensor body for 10 seconds. If successful, the LED will flash 5 times rapidly.
Inclusion Inclusion: Add the device into your network by a Z-Wave certied controller. If the controller is SmartStart compatible, refer to the controller manufacturer app that allows the DSK code to be scanned, and scan the DSK code on the inside of the battery door or on the box. If your controller is not S2/ SmartStart compatible, the device can be added using the traditional method for Z-Wave as follows:1. Place your controller into Inclusion (Add) mode by following the controller manufacturer's instructions.2. When the controller is ready, single click the button of LD-100. The controller should indicate that the new device was added successfully. If the controller shows it failed, repeat the procedure.
Exclusion Exclusion:Removethe device from your network by a Z-Wave certied controller. The device can be removed using the traditional method for Z-Wave as follows:1. Place your controller into Exclusion mode by following the controller manufacturer's instructions.2. When the controller is ready, single click the button of LD-100. The controller should indicate that the new device was removed successfully. If the controller shows it failed, repeat the procedure.
NIF XXXNIF
Wakeup When on battery power, the unit will stay awake for 5 minutes when the button is pressed to complete inclusion process. Once included, the unit will wake up every 60 seconds and detect for water.Also, the unit will wake up every hour to report temperature to the controller.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 1. BATTERY_REPORT2. NOTIFICATION_REPORT3. SENSOR_MULTILEVEL_REPORT4. DEVICE_RESET_LOCALLY_NOTIFICATION5. Z-Wave Plus Lifeline
2 5 Group 2: Basic Set, you can associate up to ve Z-Wave devices to Group 2. LD-100 will send a Basic Set to the associated devices, for example, turning on lights or engaging the water auto shut-o valve, when water is detected.

Configuration Parameters

Parameter 2: Water detection beep frequency

Parameter 2 is for the beep interval when on battery power and on USB power during the time water is detected.0= every 10 minutes1= every 5 minutes2= every 30 minutes
Size: 1 Byte, Default Value: 0

Setting Description
0 - 2 Parameter 2 is for the beep interval when on battery power and on line power during the time water is detected.0= every 10 minutes 1= every 5 minutes 2= every 30 minutes

Parameter 3: Temperature reporting interval

Parameter 3 defines the temperature interval of reporting to the controller on line power in seconds, the default value is 60.
Size: 1 Byte, Default Value: 60

Setting Description
30 - 255 Parameter 3 defines the temperature interval of reporting to the controller on line power in seconds, the default value is 60.

Parameter 4: Notification buzzer

The buzzer may be disabled when detecting water on line power or battery, using parameter 4, the default value is set to enabled.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 The buzzer may be disabled when detecting water on line power or battery, using parameter 4, the default value is set to enabled.

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 255 FW: 50.06
Z-Wave Version 6.81.01
Certification ID ZC10-18096237
Z-Wave Product Id 0x0315.0x0202.0x0001
Supported Notification Types Water Alarm
Firmware Updatable Updatable by Consumer by RF
Color White
Outdoor Use ok
Sensors Air TemperatureMoisture
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor