1. To include this device in a Z-Wave network, select the command on your Z Wave controller for inclusion (Install, Add Device,Add Node, Include Device, etc.). Then press the device ON/OFF button one time to include it in the network.2. Based on the controller, the controller may ask you to scan the QR code or manually enter 5 digit code under the QR codeto install the device as a secured device. You may find this QR code on the device or included in device packaging.3. After the Device is added to the network, the blue indicator LED will stop blinking. This indicates the device is installed in the Z-Wavenetwork.
Eatons Z-Wave plus wireless switch replaces regular switches (where a neutral is present) to provide local and remote ON/OFF control for most common residential lighting loads including LEDs and certain motor loads. Each switch can be manually and remotely controlled by commands sent from your compatible Z-Wave certified controller. Features & Benefits:Replaces standard switch to add local and wireless controlSingle pole and 3-Way control: Use with standard 3-Way switch or Z-Wave Plus Accessory RF9617Neutral is required for installationSupports motors loads up toHPFeatures blue loadindicating LED light that can be dimmed in ON or OFF state
Reset to factory default | Please use this procedure only when the network primary controller is missing or otherwise inoperable.The device could be reset locally. This will cause the device to be excluded from its network and restore to factory default.Before leaving the network the switch will send a notification to the controller indicating its departure from the Z-Wave network.1. Turn the device ON.2. Press and hold ON/OFF button for 20 second till the LED flashes for the third time.3. Release the ON/OFF button.4. LED will start flashing rapidly. Once the LED starts blinking slowly, that indicates the device is not part of the network. |
Inclusion | 1. To include this device in a Z-Wave network, select the command on your Z Wave controller for inclusion (Install, Add Device,Add Node, Include Device, etc.). Then press the device ON/OFF button one time to include it in the network.2. Based on the controller, the controller may ask you to scan the QR code or manually enter 5 digit code under the QR codeto install the device as a secured device. You may find this QR code on the device or included in device packaging.3. After the Device is added to the network, the blue indicator LED will stop blinking. This indicates the device is installed in the Z-Wavenetwork. |
Exclusion | 1. To exclude this device from a Z-Wave network, select the setting on your Z-Wave controller for exclusion(Uninstall, Remove Device, Remove Node, Exclude Device, etc.).2. Once your controller is in exclusion mode, press the device ON/OFF button one time to exclude it from the network. The LED will startblinking. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
2 | 5 | ON/OFF |
Turn the switch off with a preset delay. The default is 10 seconds. You can set this anywhere between 1 second till 127 seconds. The default is set at 10 Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 127 | Delayed OFF Time |
Adjust the brightness of the Blue LED when switch is ON0 = OFF4 = Maximum brightness Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | Indicator Light stays OFF |
1 - 4 | Increase the level of brightness |
Adjust brightness of the blue indicator LED with Switch is OFF0 = OFF4 = Maximum brightness Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Indicator Light stays OFF |
1 - 4 | Increase the level of brightness |
The interval when the switch Turns ON when Panic Mode is set to ON Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 127 | Panic ON Time |
The interval when the switch Turns OFF when Panic Mode is set to ON Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 127 | Panic OFF Time |
Power UP state allows the users to set the state the device will come ON after power is restored. 1 = OFF 2 = ON3 = Last StateDefault is OFF Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Turn OFF when Power is back |
2 | Turn ON when Power is back |
3 | Default to Last State when Power is Back |
Panic Mode allows Eaton Z-Wave devices to Turn ON/OFF at a press of button. 0 = OFF1 = ON Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Panic Mode is Turned OFF |
1 | Panic Mode is Turned ON |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 255 FW: 2.00 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-18096234 |
Z-Wave Product Id | 0x001A.0x534C.0x0503 |
Neutral Wire Required | ok |
Firmware Updatable | Updatable by Consumer by RF |
Electric Load Type | Dimmable ELV (Magnetic)Dimmable FluorescentDimmable LEDDimmable MLV (Magnetic)ELV (Electronic)FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic) |
Switch Type | Decorator Paddle Push with Indicator |
Z-Wave Scene Type | Scene |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |