Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. To include this device in a Z-Wave network, select the command on your Z Wave controller for inclusion (Install, Add Device,Add Node, Include Device, etc.). Then press the device ON/OFF button one time to include it in the network.2. Based on the controller, the controller may ask you to scan the QR code or manually enter 5 digit code under the QR codeto install the device as a secured device. You may find this QR code on the device or included in device packaging.3. After the Device is added to the network, the blue indicator LED will stop blinking. This indicates the device is installed in the Z-Wavenetwork.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Eatons Z-Wave Plus Wireless Receptacle replaces regular receptacles to provide local and remote wireless ON/OFF control of a single outlet. Each receptacle can be manually and remotely controlled by commands sent from your compatible Z-Wave certified controller. Features & Benefits:Rated for up toHP motor loadsProvides Z-Wave control of one outlet leaving the other one for normal useSafety shutter system prevents insertion of foreign objects into receptacleCan be associated with up to 5 other devicesBlue LED at center illuminates to indicate ON/OFF statusPatented indicator system alerts if receptacle is not set up in the networkSingle pole and 3-Way control: Use with standard 3-Way switch or Z-Wave Plus Accessory RF9617Neutral is required for installationSupports Z-Wave Plus technology including S2 Security certification for advanced encryption & cybersecurityVoice and app based control when used with compatible Z-Wave controller

Reset to factory default Please use this procedure only when the network primary controller is missing or otherwise inoperableThe device could be reset locally. This will cause the device to be excluded from its network and restore to factory default.Before leaving the network the switch will send a notification to the controller indicating its departure from the Z-Wave network.1. Turn the device ON.2. Press and hold ON/OFF button for 20 second till the LED flashes for the third time.3. Release the ON/OFF button.4. LED will start flashing rapidly. Once the LED starts blinking slowly, that indicates the device is not part of the network.
Inclusion 1. To include this device in a Z-Wave network, select the command on your Z Wave controller for inclusion (Install, Add Device,Add Node, Include Device, etc.). Then press the device ON/OFF button one time to include it in the network.2. Based on the controller, the controller may ask you to scan the QR code or manually enter 5 digit code under the QR codeto install the device as a secured device. You may find this QR code on the device or included in device packaging.3. After the Device is added to the network, the blue indicator LED will stop blinking. This indicates the device is installed in the Z-Wavenetwork.
Exclusion 1. To exclude this device from a Z-Wave network, select the setting on your Z-Wave controller for exclusion(Uninstall, Remove Device, Remove Node, Exclude Device, etc.).2. Once your controller is in exclusion mode, press the device ON/OFF button one time to exclude it from the network. The LED will start blinking.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline
2 5 ON/OFF

Configuration Parameters

Parameter 1: Delayed OFF Time

Press and Hold sequence for Delayed OFF. Turns off the receptacle after a set time interval. The default is 10 seconds with available values from 0 to 127 secs
Size: 1 Byte, Default Value: 10

Setting Description
0 - 127 Delayed OFF Time

Parameter 13: BLUE LED Brightness level while the receptacle is ON

Light Intensity ofIndicator LED
Size: 1 Byte, Default Value: 3

Setting Description
0 Indicator light stays OFF
1 - 4 Increase the brightness of indicator light

Parameter 14: BLUE LED Brightness level while the receptacle is OFF

Light Intensity ofIndicator LED
Size: 1 Byte, Default Value: 1

Setting Description
0 Indicator light stays OFF
1 - 4 Increase the brightness of indicator light

Parameter 2: Panic ON Time

Time interval for receptacle to be ON when Panic Mode is enabled
Size: 1 Byte, Default Value: 1

Setting Description
0 - 127 Interval after which device will turn ON during panic mode

Parameter 3: Panic OFF Time

Time interval for receptacle to be ON when Panic Mode is enabled
Size: 1 Byte, Default Value: 1

Setting Description
0 - 127 Interval after which device will turn OFF during panic mode

Parameter 5: Power Up State

1 = OFF 2 = ON3 = Last State
Size: 1 Byte, Default Value: 1

Setting Description
1 Turn OFF when power is restored
2 Turn ON when power is restored
3 Return to last state when power is restored

Parameter 6: Panic Mode Enabled

0=OFF1=ON
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable Panic Mode
1 Enable Panic Mode

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 0 FW: 2.00
Z-Wave Version 6.71.03
Certification ID ZC10-18096232
Z-Wave Product Id 0x001A.0x5244.0x0505
Switch Type Push Button with Indicator
Z-Wave Scene Type Scene
Electric Load Type Dimmable ELV (Magnetic)Dimmable FluorescentDimmable LEDDimmable MLV (Magnetic)ELV (Electronic)FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic)
Neutral Wire Required ok
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoOn/Off Power Switch