This is a
1. To include this device in a Z-Wave network, select the command on your Z Wave controller for inclusion (Install, Add Device,Add Node, Include Device, etc.). Then press the device ON/OFF button one time to include it in the network.2. Based on the controller, the controller may ask you to scan the QR code or manually enter 5 digit code under the QR codeto install the device as a secured device. You may find this QR code on the device or included in device packaging.3. After the Device is added to the network, the blue indicator LED will stop blinking. This indicates the device is installed in the Z-Wavenetwork.
Eatons Z-Wave Plus Wireless Receptacle replaces regular receptacles to provide local and remote wireless ON/OFF control of a single outlet. Each receptacle can be manually and remotely controlled by commands sent from your compatible Z-Wave certified controller. Features & Benefits:Rated for up toHP motor loadsProvides Z-Wave control of one outlet leaving the other one for normal useSafety shutter system prevents insertion of foreign objects into receptacleCan be associated with up to 5 other devicesBlue LED at center illuminates to indicate ON/OFF statusPatented indicator system alerts if receptacle is not set up in the networkSingle pole and 3-Way control: Use with standard 3-Way switch or Z-Wave Plus Accessory RF9617Neutral is required for installationSupports Z-Wave Plus technology including S2 Security certification for advanced encryption & cybersecurityVoice and app based control when used with compatible Z-Wave controller
Reset to factory default | Please use this procedure only when the network primary controller is missing or otherwise inoperableThe device could be reset locally. This will cause the device to be excluded from its network and restore to factory default.Before leaving the network the switch will send a notification to the controller indicating its departure from the Z-Wave network.1. Turn the device ON.2. Press and hold ON/OFF button for 20 second till the LED flashes for the third time.3. Release the ON/OFF button.4. LED will start flashing rapidly. Once the LED starts blinking slowly, that indicates the device is not part of the network. |
Inclusion | 1. To include this device in a Z-Wave network, select the command on your Z Wave controller for inclusion (Install, Add Device,Add Node, Include Device, etc.). Then press the device ON/OFF button one time to include it in the network.2. Based on the controller, the controller may ask you to scan the QR code or manually enter 5 digit code under the QR codeto install the device as a secured device. You may find this QR code on the device or included in device packaging.3. After the Device is added to the network, the blue indicator LED will stop blinking. This indicates the device is installed in the Z-Wavenetwork. |
Exclusion | 1. To exclude this device from a Z-Wave network, select the setting on your Z-Wave controller for exclusion(Uninstall, Remove Device, Remove Node, Exclude Device, etc.).2. Once your controller is in exclusion mode, press the device ON/OFF button one time to exclude it from the network. The LED will start blinking. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
2 | 5 | ON/OFF |
Press and Hold sequence for Delayed OFF. Turns off the receptacle after a set time interval. The default is 10 seconds with available values from 0 to 127 secs Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 127 | Delayed OFF Time |
Light Intensity ofIndicator LED Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | Indicator light stays OFF |
1 - 4 | Increase the brightness of indicator light |
Light Intensity ofIndicator LED Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Indicator light stays OFF |
1 - 4 | Increase the brightness of indicator light |
Time interval for receptacle to be ON when Panic Mode is enabled Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 127 | Interval after which device will turn ON during panic mode |
Time interval for receptacle to be ON when Panic Mode is enabled Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 127 | Interval after which device will turn OFF during panic mode |
1 = OFF 2 = ON3 = Last State Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 | Turn OFF when power is restored |
2 | Turn ON when power is restored |
3 | Return to last state when power is restored |
0=OFF1=ON Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable Panic Mode |
1 | Enable Panic Mode |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 0 FW: 2.00 |
Z-Wave Version | 6.71.03 |
Certification ID | ZC10-18096232 |
Z-Wave Product Id | 0x001A.0x5244.0x0505 |
Switch Type | Push Button with Indicator |
Z-Wave Scene Type | Scene |
Electric Load Type | Dimmable ELV (Magnetic)Dimmable FluorescentDimmable LEDDimmable MLV (Magnetic)ELV (Electronic)FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic) |
Neutral Wire Required | ok |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |