Quickstart

This is a secure Siren for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
The device will enter Smart Start if the device is not included in network after power up. And if device is not included successfully during 10 second, it will enter sleep mode. And then2nd Smart Start time delay approximately 16s3rd Smart Start time delay approximately 32s4th Smart Start time delay approximately 64s5th Smart Start time delay approximately 128s6th Smart Start time delay approximately 256s7th Smart Start time delay approximately 512sAfterwards, the Smart start mode will be auto running with 512 second interval until device is included successfully or battery run down.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Reset to factory default 1 Power up the device.2 Press and hold the button for 10s until led lights ison, then release the button.Please use this procedure only when the network primary controller is missing or otherwise inoperable
Inclusion The device will enter Smart Start if the device is not included in network after power up. And if device is not included successfully during 10 second, it will enter sleep mode. And then2nd Smart Start time delay approximately 16s3rd Smart Start time delay approximately 32s4th Smart Start time delay approximately 64s5th Smart Start time delay approximately 128s6th Smart Start time delay approximately 256s7th Smart Start time delay approximately 512sAfterwards, the Smart start mode will be auto running with 512 second interval until device is included successfully or battery run down.
Exclusion The device will enter Smart Start if the device is not included in network after power up. And if device is not included successfully during 10 second, it will enter sleep mode. And then2nd Smart Start time delay approximately 16s3rd Smart Start time delay approximately 32s4th Smart Start time delay approximately 64s5th Smart Start time delay approximately 128s6th Smart Start time delay approximately 256s7th Smart Start time delay approximately 512sAfterwards, the Smart start mode will be auto running with 512 second interval until device is included successfully or battery run down.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus LifelineCommand ClassCOMMAND_CLASS_NOTIFICATIONCOMMAND_CLASS_SWITCH_BINARYCOMMAND_CLASS_BATTERYCOMMAND_CLASS_DEVICE_RESET_LOCALLYEventNOTIFICATION_REPORTSWITCH_BINARY_REPORTBATTERY_REPORTDEVICE_RESET_LOCALLY_NOTIFICATION

Special Operations as Z-Wave Controller

As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:

Inclusion of other devices

Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.

If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.

To become primary a contoller have to be resetted and then include a device.

1 Power up the device.2 Set Z-Wave Controller into inclusion mode3 Press the button 3 times within 1.5s to enter inclusion mode.4 The device willberecognized andautomaticallyincludedintoZ-Wave Network.

Exclusion of other devices

The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.

Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.

1 Power up the device.2 Set Z-Wave Controller into exclusion mode3 Press the button 3 times within 1.5s to enter exclusion mode

Configuration Parameters

Parameter 1: Alarm Sound Volume

This parameter defines the output volume when siren plays door bell sound. Door Bell sound volume is divided into 3 stages, Low (Parameter is set to 1), Middle (Parameter is set to 2), High (Parameter is set to 3). Default value is 3.
Size: 1 Byte, Default Value: 3

Setting Description
1 - 3 Alarm Sound Volume

Parameter 2: Alarm Sound Duration Time

This Parameter defines the alarm sound duration time when siren receive an alarm sensor notification report or an alarm command from controller.The duration time is divided into 5 stages: Siren is not on (Parameter is set to 0), 30 second (Parameter is set to 1), 1 minute (Parameter is set to 2), 5 minute (Parameter is set to 3) Siren is always on until battery is dead (Parameter is set to 0x7F).Default value is 2.The value for this parameter is unsigned value.
Size: 1 Byte, Default Value: 2

Setting Description
0 - 3 Alarm Sound Duration Time
127 Always alarm

Parameter 3: Door Bell Sound Duration Time

This parameter defines the door bell sound duration time when siren receives a door/window sensor notification report or an alarm command (BASIC_SET = 0x02) from controller. The door bell sound will be played always if this parameter is set to 0x7F. The door bell sound will not beplayed if this parameter is set to 0. Other values are the door bell sound playing duration time.Unit: Time.The value for this parameter is unsigned value.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 127 Door Bell Sound Duration Time

Parameter 4: Door Bell Sound Volume

This parameter defines the output volume when siren plays alarm sound. Door Bell sound volume is divided into 3 stages: Low (Parameter is set to 1), Middle (Parameter is set to 2), High(Parameter is set to 3). Default value is 1.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 3 Door Bell Sound Volume

Parameter 5: Alarm Sound Index

This parameter defines the alarm sound index for siren play different sound when alarm occurs. There are 10 different sound for user selection.
Size: 1 Byte, Default Value: 10

Setting Description
1 - 10 Alarm Sound Index

Parameter 6: Door Bell Sound Index

This parameter defines the door bell sound index for siren play different sound when alarm occurs. There are 10 different sound for user selection.
Size: 1 Byte, Default Value: 9

Setting Description
1 - 10 Door Bell Sound Index

Parameter 7: Default Siren On Mode

This parameter defines the default sound index, volume and the duration time for siren on. This parameter can be selected between ALARM SOUND and DOOR BELL SOUND. The settings for ALARM SOUND MODE defines by Param #1, #2 and #5. The settings for DOOR BELL SOUND MODE defines by Param #3, #4 and #6.If parameter is set to 1, siren will select ALARM SOUND MODE to play sound;If parameter is set to 2, siren will select DOOR BELL SOUND MODE to play sound;
Size: 1 Byte, Default Value: 1

Setting Description
1 - 2 Default Siren On Mode

Parameter 8: Alarm Led Enable

This parameter defines the default led enable status when siren is on for ALARM SOUND MODE.If parameter is set to 0, led will be disable.If parameter is set t0 1, led will be enable. When siren is on, the led will blink.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 Alarm mode switching

Parameter 9: Door Bell Led Enable

This parameter defines the default led enable status when siren is on for DOOR BELL SOUND MODE.If parameter is set to 0, led will be disable.If parameter is set t0 1, led will be enable. When siren is on, the led will blink.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 Door Bell Led Enable

Technical Data

Hardware Platform ZM5202
Device Type Siren
Network Operation Listening Sleeping Slave
Firmware Version HW: 96 FW: 2.17
Z-Wave Version 6.81.01
Certification ID ZC10-18096227
Z-Wave Product Id 0x0258.0x0200.0x1028
Firmware Updatable Updatable by Professional/Technician
Color White
Sensors Open/Closed (Binary)
Gateway Has Preferred Partners ok
Supported Notification Types Home SecuritySiren
Communications Connections None
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Siren