This is a
The device will enter Smart Start if the device is not included in network after power up. And if device is not included successfully during 10 second, it will enter sleep mode. And then2nd Smart Start time delay approximately 16s3rd Smart Start time delay approximately 32s4th Smart Start time delay approximately 64s5th Smart Start time delay approximately 128s6th Smart Start time delay approximately 256s7th Smart Start time delay approximately 512sAfterwards, the Smart start mode will be auto running with 512 second interval until device is included successfully or battery run down.
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Reset to factory default | 1 Power up the device.2 Press and hold the button for 10s until led lights ison, then release the button.Please use this procedure only when the network primary controller is missing or otherwise inoperable |
Inclusion | The device will enter Smart Start if the device is not included in network after power up. And if device is not included successfully during 10 second, it will enter sleep mode. And then2nd Smart Start time delay approximately 16s3rd Smart Start time delay approximately 32s4th Smart Start time delay approximately 64s5th Smart Start time delay approximately 128s6th Smart Start time delay approximately 256s7th Smart Start time delay approximately 512sAfterwards, the Smart start mode will be auto running with 512 second interval until device is included successfully or battery run down. |
Exclusion | The device will enter Smart Start if the device is not included in network after power up. And if device is not included successfully during 10 second, it will enter sleep mode. And then2nd Smart Start time delay approximately 16s3rd Smart Start time delay approximately 32s4th Smart Start time delay approximately 64s5th Smart Start time delay approximately 128s6th Smart Start time delay approximately 256s7th Smart Start time delay approximately 512sAfterwards, the Smart start mode will be auto running with 512 second interval until device is included successfully or battery run down. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus LifelineCommand ClassCOMMAND_CLASS_NOTIFICATIONCOMMAND_CLASS_SWITCH_BINARYCOMMAND_CLASS_BATTERYCOMMAND_CLASS_DEVICE_RESET_LOCALLYEventNOTIFICATION_REPORTSWITCH_BINARY_REPORTBATTERY_REPORTDEVICE_RESET_LOCALLY_NOTIFICATION |
As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:
Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.
If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.
To become primary a contoller have to be resetted and then include a device.
1 Power up the device.2 Set Z-Wave Controller into inclusion mode3 Press the button 3 times within 1.5s to enter inclusion mode.4 The device willberecognized andautomaticallyincludedintoZ-Wave Network.
The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.
Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.
1 Power up the device.2 Set Z-Wave Controller into exclusion mode3 Press the button 3 times within 1.5s to enter exclusion mode
This parameter defines the output volume when siren plays door bell sound. Door Bell sound volume is divided into 3 stages, Low (Parameter is set to 1), Middle (Parameter is set to 2), High (Parameter is set to 3). Default value is 3. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 3 | Alarm Sound Volume |
This Parameter defines the alarm sound duration time when siren receive an alarm sensor notification report or an alarm command from controller.The duration time is divided into 5 stages: Siren is not on (Parameter is set to 0), 30 second (Parameter is set to 1), 1 minute (Parameter is set to 2), 5 minute (Parameter is set to 3) Siren is always on until battery is dead (Parameter is set to 0x7F).Default value is 2.The value for this parameter is unsigned value. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 3 | Alarm Sound Duration Time |
127 | Always alarm |
This parameter defines the door bell sound duration time when siren receives a door/window sensor notification report or an alarm command (BASIC_SET = 0x02) from controller. The door bell sound will be played always if this parameter is set to 0x7F. The door bell sound will not beplayed if this parameter is set to 0. Other values are the door bell sound playing duration time.Unit: Time.The value for this parameter is unsigned value. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 127 | Door Bell Sound Duration Time |
This parameter defines the output volume when siren plays alarm sound. Door Bell sound volume is divided into 3 stages: Low (Parameter is set to 1), Middle (Parameter is set to 2), High(Parameter is set to 3). Default value is 1. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 3 | Door Bell Sound Volume |
This parameter defines the alarm sound index for siren play different sound when alarm occurs. There are 10 different sound for user selection. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 10 | Alarm Sound Index |
This parameter defines the door bell sound index for siren play different sound when alarm occurs. There are 10 different sound for user selection. Size: 1 Byte, Default Value: 9
Setting | Description |
---|---|
1 - 10 | Door Bell Sound Index |
This parameter defines the default sound index, volume and the duration time for siren on. This parameter can be selected between ALARM SOUND and DOOR BELL SOUND. The settings for ALARM SOUND MODE defines by Param #1, #2 and #5. The settings for DOOR BELL SOUND MODE defines by Param #3, #4 and #6.If parameter is set to 1, siren will select ALARM SOUND MODE to play sound;If parameter is set to 2, siren will select DOOR BELL SOUND MODE to play sound; Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 2 | Default Siren On Mode |
This parameter defines the default led enable status when siren is on for ALARM SOUND MODE.If parameter is set to 0, led will be disable.If parameter is set t0 1, led will be enable. When siren is on, the led will blink. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | Alarm mode switching |
This parameter defines the default led enable status when siren is on for DOOR BELL SOUND MODE.If parameter is set to 0, led will be disable.If parameter is set t0 1, led will be enable. When siren is on, the led will blink. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Door Bell Led Enable |
Hardware Platform | ZM5202 |
Device Type | Siren |
Network Operation | Listening Sleeping Slave |
Firmware Version | HW: 96 FW: 2.17 |
Z-Wave Version | 6.81.01 |
Certification ID | ZC10-18096227 |
Z-Wave Product Id | 0x0258.0x0200.0x1028 |
Firmware Updatable | Updatable by Professional/Technician |
Color | White |
Sensors | Open/Closed (Binary) |
Gateway Has Preferred Partners | ok |
Supported Notification Types | Home SecuritySiren |
Communications Connections | None |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |