This is a
1. Start the COQON App2. Select "Device" then "Settings" and tap on "+" to add your Electric Monitor3. Select "Add new COQON device" 4. Follow the steps in the App
The power monitor measures and registers power consumption to help users understand their energy consumption. The measurement takes place per circuit. This information may be useful for those who want to reduce their energy consumption or use energy-efficient behavior.They provide insights into areas in their home where more energy is consumed than in others.Product Compliance:This product meets the essential requirements of (RED) 2014/53 / EU and 2011/65 / EU. The full text of the EU Declaration of Conformity can be found on www.coqon.de.Technical specifications:Model no. EMHTZ001Mains voltage230V, 50 HzAmbient temperature0-45CDimensions100x100x31mmRadio language Z-Wave Plus
Reset to factory default | To reset the device to factory default press and hold the function button for 10 seconds. Note: Please use this procedure ony when the network primary controller is missing or otherwise inoperabe! |
Inclusion | 1. Start the COQON App2. Select "Device" then "Settings" and tap on "+" to add your Electric Monitor3. Select "Add new COQON device" 4. Follow the steps in the App |
Exclusion | 1. Start the COQON App2. Select "Device" then "Settings" and tap on the device to remove Electric Monitor3. Tap on the the trash can icon4. Follow the steps in the App |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
Percentage change in wattage to induce an automatic report (Clamp 1) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 100 | Valid values 0-100 |
Auto report KWh Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 31 | Valid values 0 - 31, Bit 0: Whole EM, Bit 1: Clamp 1, Bit 2: Clamp 2, Bit 3: Clamp 3, Bit 4: Clamp 4 |
Auto report W Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 31 | Valid values 0 - 31, Bit 0: Whole EM, Bit 1: Clamp 1, Bit 2: Clamp 2, Bit 3: Clamp 3, Bit 4: Clamp 4 |
Auto report V Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 31 | Valid values 0 - 31, Bit 0: Whole EM, Bit 1: Clamp 1, Bit 2: Clamp 2, Bit 3: Clamp 3, Bit 4: Clamp 4 |
Auto report A Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 31 | Valid values 0 - 31, Bit 0: Whole EM, Bit 1: Clamp 1, Bit 2: Clamp 2, Bit 3: Clamp 3, Bit 4: Clamp 4 |
Auto report kVar Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 31 | Valid values 0 - 31, Bit 0: Whole EM, Bit 1: Clamp 1, Bit 2: Clamp 2, Bit 3: Clamp 3, Bit 4: Clamp 4 |
Percentage change in wattage to induce an automatic report (Clamp 2) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 100 | Valid values 0-100 |
The Time interval of Auto report kWh Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Valid values 0x1E-0x7FFFFFFF |
The Time interval of Auto report W Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Valid values 0x1E-0x7FFFFFFF |
The Time interval of Auto report V Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Valid values 0x1E-0x7FFFFFFF |
The Time interval of Auto report A Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Valid values 0x1E-0x7FFFFFFF |
The Time interval of Auto report kVar Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Valid values 0x1E-0x7FFFFFFF |
Percentage change in wattage to induce an automatic report (Clamp 3) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 100 | Valid values 0-100 |
Percentage change in wattage to induce an automatic report (Clamp 4) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 100 | Valid values 0-100 |
Energy detection mode Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | 0 = Report Power, Energy absolute value. |
1 | 1 = Report positive / negative power, report the algebraic sum energy. |
2 | 2 = Report positive / negative power, only report energy positive part (consuming electricity). |
3 | 3 = Report positive / negative power, only report energy negative part (generating electricity). |
Enable selective reporting only when power change reaches a certain threshold or percentage set in parameters 4-11 below. This is used to reduce the network traffic. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | 0 = disable |
1 | 1 = Enable |
Threshold change in wattage to induce an automatic report (Whole EM) Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 30000 | Valid values 0-30000 |
Threshold change in wattage to induce an automatic report (Clamp 1) Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 30000 | Valid values 0-30000 |
Threshold change in wattage to induce an automatic report (Clamp 2) Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 30000 | Valid values 0-30000 |
Threshold change in wattage to induce an automatic report (Clamp 3) Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 30000 | Valid values 0-30000 |
Threshold change in wattage to induce an automatic report (Clamp 4) Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
0 - 30000 | Valid values 0-30000 |
Percentage change in wattage to induce an automatic report (wohle EM) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 100 | Valid values 0-100 |
Hardware Platform | ZM5101 |
Device Type | Sub Energy Meter |
Network Operation | Always On Slave |
Firmware Version | HW: 0 FW: 1.03 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18086207 |
Z-Wave Product Id | 0x0140.0x0803.0x1003 |
Supported Meter Type | Electric Energy |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |