Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
New Installation1. For proper inclusion, bring the Door/Window Sensor Pro to the final location where it will be used*.2. Follow the instructions for your Z-Wave controller to enter inclusion mode.3. Remove the Battery Tab protruding from the Battery Tab Slit.4. The device will automatically enter inclusion mode for two minutes and the LED Indicator will alternate between green and red.Upon successful inclusion the LED Indicator will flash green three times then stop blinking.Re-Installation1. For proper inclusion, bring the Door/Window Sensor Proto the final location where it will be used*.2. Follow the instructions for your Z-Wave controller to enter inclusion mode.3. Remove the Sensor Cover and the LED Indicator will start blinking yellow.4. Press the Button quickly 3 times in a row.5. The device will enter inclusion mode for two minutes and the LED Indicator will alternate between green and red.After successful inclusion, the LED Indicator will flash green three times then blink red until the cover is replaced.*For non Z-Wave Plus networks, please consult the owners manual for your primary controller to determine the best method and location for adding the Door/Window Sensor Pro to your Z-Wave network.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The Dome Door/Window Sensor Pro is a battery powered security-enabled* Z-Wave Plus magnetic reed switch that can monitor the status of doors, windows, and anything else that opens and closes.It can also report ambient temperature levels.The Door/Window Sensor consists of two parts - the sensor, and the magnet.The sensor has a reed switch inside, which is sensitive to the magnets presence when aligned properly and within the defined distance.When the sensor and magnet are brought together or pulled apart, the sensor will report its open/close status to its Z-Wave controller, and the encrypted wireless communication* ensures that user data remains secure. Because many manufacturers use Z-Wave to communicate, the Door/Window Sensor can interact with different products of different categories. Z-Wave Plus Certified S0 Security-Enabled* Built-In Temperature Sensor Up to 250 range Ten-Year Battery Life LED Signal Strength Indication 1.25 Max distance between sensor & magnet Ultra-Narrow (1/4) Magnet for Placement Between Door and Casing Monitor doors, windows, medicine cabinets, drawers, garage doors, and many other openings

Reset to factory default If needed, the Door/Window Sensor Pro can be reset locally by following these steps.Only do this if your Z-Wave controller is missing or otherwise unreachable.Beware that resetting your device will disconnect it from the system:1. Remove the Sensor Cover and confirm that your Door/Window Sensor Pro is powered up.2. Wait for 5 seconds.3. Move the Magnet and Sensor Base in and out of the closed position 6 times.4. The LED Indicator will light up red for five seconds when reset successfully.The Door/Window Sensor Pro memory will be erased to factory settings.
Inclusion New Installation1. For proper inclusion, bring the Door/Window Sensor Pro to the final location where it will be used*.2. Follow the instructions for your Z-Wave controller to enter inclusion mode.3. Remove the Battery Tab protruding from the Battery Tab Slit.4. The device will automatically enter inclusion mode for two minutes and the LED Indicator will alternate between green and red.Upon successful inclusion the LED Indicator will flash green three times then stop blinking.Re-Installation1. For proper inclusion, bring the Door/Window Sensor Proto the final location where it will be used*.2. Follow the instructions for your Z-Wave controller to enter inclusion mode.3. Remove the Sensor Cover and the LED Indicator will start blinking yellow.4. Press the Button quickly 3 times in a row.5. The device will enter inclusion mode for two minutes and the LED Indicator will alternate between green and red.After successful inclusion, the LED Indicator will flash green three times then blink red until the cover is replaced.*For non Z-Wave Plus networks, please consult the owners manual for your primary controller to determine the best method and location for adding the Door/Window Sensor Pro to your Z-Wave network.
Exclusion Follow the instructions for your Z-Wave Certified Controller to enter exclusion mode.When prompted by the controller:Remove the SENSOR COVER and the LED Indicator will start blinking red.Press the Button quickly 3 times in a row.The LED Indicator will flash green three times indicating exclusion/disconnection and will then continue flashing red (indicating tamper) until the cover is replaced.
NIF XXXNIF
Wakeup Because the Door/Window Sensor Pro is a battery powered device, it wakes up on regular intervals to give battery and other status updates to the controller, as well as to accept configuration settings from the controller.This helps to extend the battery life.The Sensor Cover holds down the Button when installed, and the device can be forced to wake up to submit reports or accept new settings immediately by simply removing the Sensor Cover and then replacing it after.If the device is already included in a system, the LED Indicator will flash Red until the cover is closed.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is the Lifeline group, which can hold five members, typically including the main Z-Wave controller.The Door/Window Sensor Pro sends this group a Notification Report or a Binary Sensor Report when it is opened or closed (see Configuration Parameter 3.)It also sends this group a multilevel sensor report to report the temperature and a Battery Report in response to Battery Get commands.
2 5 Group 2 supports up to 5 members and the Door/Window Sensor Pro sends a Basic Set command to this group (or the Control Group) to directly trigger devices (like a light, chime, etc.) when the tamper switch either opens or closes. The value of the Basic Set command (e.g. brightness of the lamp) is configured using configuration parameter 07.
3 5 Group 3 supports up to 5 members and the Door/Window Sensor Pro sends it a NOTIFICATION_REPORT or SENSOR_BINARY_REPORT when the tamper switch either opens or closes.
4 5 Group 4 supports up to 5 members and the Door/Window Sensor Pro sends a Basic Set command to this group to directly trigger devices (like a light, chime, etc.) when the sensor detects the door/window opening or closing. The value of the Basic Set command (e.g. brightness of the lamp) is configured using configuration parameters 08 and 09.
5 5 Group 5 supports up to 5 members and the Door/Window Sensor Pro sends it a NOTIFICATION_REPORT or SENSOR_BINARY_REPORT when the sensor detects the door/window opening.

Configuration Parameters

Parameter 1: Enable/Disable LED Indicator

This parameter enables or disables the LED Indicator flashing to indicate opening and closing events.The Door/Window Sensor Pro will always flash the LED Indicator for inclusion, exclusion, tamper, and other system events.
Size: 1 Byte, Default Value: 1

Setting Description
0 Open/Close LED Indicator Disabled
1 Open/Close LED Indicator Enabled

Parameter 2: Configure Open/Close Reports Sent

This parameter switches the Notification or Binary Sensor report sent when the door opens or closes.If this parameter is set to 01, the Door/Window Sensor Pro will report closed instead of openwhen the Magnet and Sensor are pulled apart.
Size: 1 Byte, Default Value: 0

Setting Description
0 Reports Closed when Magnet is close
1 Reports Open when Magnet is close

Parameter 3: Switch Between Notification and Binary Sensor Command Classes

By default, the Door/Window Sensor Pro uses the Notification command class to communicate open/close and tamper events.If this Parameter is set to 1, the device will instead use the Binary Sensor command class.To apply this setting, the battery needs be removed and replaced!This is because the supported command classes will change according to this setting, so the device must restart to advertise its new command classes.
Size: 1 Byte, Default Value: 0

Setting Description
0 Both Command Classesare Used
1 Notification Command Class is Used
2 Binary Sensor Command Class is Used

Parameter 4: Enable/Disable Temperature Sensor

The Door/Window Sensor Pro can also monitor and report ambient temperature conditions.However, temperature sensing functionality is disabled by default to save battery life, and this configuration parameter is used to enable or disable this feature.To apply this setting, the battery needs be removed and replaced!This is because the supported command classes will change according to this setting, so the device must restart to advertise its new command classes.
Size: 1 Byte, Default Value: 0

Setting Description
0 Temperature Sensor Disabled
1 Temperature Sensor Enabled

Parameter 5: Temperature Offset

This Configuration Parameter can offset the temperature value reported by125 degrees to compensate for temperature variances in a room - for example, the temperature near the ceiling in a room is significantly higher than the average temperature of the same room.This Parameter accepts a signed 8-bit value with an absolute value of up to 125, and its units are Dependant on Configuration Parameter 07
Size: 1 Byte, Default Value: 0

Setting Description
-125 - -1 -125 to -1 degrees offset
0 - 125 0 - 125 degrees offset

Parameter 6: Temperature Units

The Door/Window Sensor Pro can report temperature values in either Celsius or Fahrenheit, and this parameter allows the user to decide which unit is used.
Size: 1 Byte, Default Value: 0

Setting Description
0 Temperature is Reported in Fahrenheit
1 emperature is Reported in Celsius

Parameter 7: Group 2 Basic Set Value

This parameter sets the value sent by the Basic Set command to Association Group 2.The Door/Window Sensor Pro sends a Basic Set command to Association Group 2 both when the tamper switch opens and closes(for more information, see Group 2. Value is in Hexadecimal.
Size: 1 Byte, Default Value: 255

Setting Description
0 Turn Off Device
1 - 99 Set Device to Value
255 Turn On Device

Parameter 8: Basic Set Level (Group 4 Opening)

This parameter sets the value sent by the Basic Set command to Association Group 4.The Door/Window Sensor Pro sends a Basic Set command to Association Group 4 when the door or window opens (for more information, see Group 4 on page 14.) Value is in Hexadecimal.
Size: 1 Byte, Default Value: 255

Setting Description
0 Turn Off Device
1 - 99 Set Device to Value
255 Turn On Device

Parameter 9: Basic Set Level (Group 4 Closing)

This parameter sets the value sent by the Basic Set command to Association Group 4.The Door/Window Sensor Pro sends a Basic Set command to Association Group 4 when the door or window closes (for more information, see Group 4 on page 14.) Value is in Hexadecimal.
Size: 1 Byte, Default Value: 0

Setting Description
0 Turn Off Device
1 - 99 Set Device to Value
255 Turn On Device

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 3 FW: 1.01
Z-Wave Version 6.61.00
Certification ID ZC10-18076176
Z-Wave Product Id 0x021F.0x0003.0x0201
Firmware Updatable Updatable by Consumer by RF
Color White
Sensors Air TemperatureOpen/Closed (Binary)
Supported Notification Types Access ControlHome Security
Frequency XXfrequency
Maximum transmission power XXantenna
Australia / New ZealandNotification Sensor