Quickstart

This is a secure Door Lock - Keypad for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
1. Enter the 4-8 digit master PIN code followed by the gear key.2. Press the 7 key followed by the gear key.3. Press the 1 key followed by the gear key.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Expanding the Yale nexTouch product line for even more applications, the new nexTouch Sectional Mortise Keypad Lock provides robust security for a wide range of commercial and multi-family buildings. Just like the original cylindrical nexTouch lock, it is ANSI/BHMA Grade 1 certified and offered in capacitive touchscreen or pushbutton keypad versions. With just the addition of a Z-Wave Plus module, you can add this lock to compatible smart home and alarm systems. Other standard features include voice-guided programming, privacy mode with Door Position Switch, 9V battery backup, support of up to 100 unique user codes, and more.

Reset to factory default Please use this procedure only when the network primary controller is missing or otherwise inoperable.1. Remove the inside lever with the lever removal tool.2. Remove battery cover using hex wrench provided with lock.3. Remove four (4) AA batteries.4. Remove the 10-32 x 3/4" pan head screw from the center of the battery housing into the barrel nut of the outside assembly.5. Remove inside escutcheon. Cables may stay connected.6. Reinstall batteries 7. On the back of the PC board, push and hold the Reset Button with the lever removal tool for 3 seconds.8. While continuing the press the reset button, temporarily remove one AA battery.9. Reinstall the battery10. Release reset button and wait 15 seconds. Speaker will announce "Welcome to Yale"11. Reassemble escutcheon
Inclusion 1. Enter the 4-8 digit master PIN code followed by the gear key.2. Press the 7 key followed by the gear key.3. Press the 1 key followed by the gear key.
Exclusion 1. Enter the 4-8 digit master PIN code followed by the gear key.2. Press the 7 key followed by the gear key.3. Press the 3 key followed by the gear key.
NIF XXXNIF
Wakeup Touch the touchscreen with three fingers
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline

Configuration Parameters

Parameter 1: Silent Mode on/off

Level control, 1, 2, 3 default is 1. Levels are 1 and 3 for models with no spoken prompts default is 1 or high
Size: 1 Byte, Default Value: 1

Setting Description
1 - 3 Level

Parameter 11: One Touch Locking

0x00 = OFF, 0xFF = ON default is 0xFF or ON.
Size: 1 Byte, Default Value: 0

Setting Description
-128 One Touch Locking On
0 One Touch Locking Off

Parameter 12: Privacy Button

0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
-128 Privacy Button On
0 Privacy Button Off

Parameter 15: Reset to Factory Defaults

01 = Lock will execute Reset To Factory.02 = Reserved for future use (Lock will currently execute Reset To Factory same as 01). No default valuePlease use this procedure only when the network primary controller is missing or otherwise inoperable
Size: 1 Byte, Default Value: 0

Setting Description
-128 Reset to Factory On
0 Reset to Factory Off

Parameter 18: Door Propped Timer

10 to 127 second.This value is represented as seconds X 10. (ie a value of 4 would mean a door propped timer of 40 seconds) Set to 0x00 to disable Door Propped Alarm.Default = 0x00 (off)
Size: 1 Byte, Default Value: 0

Setting Description
20 - 127 Seconds

Parameter 19: DPS Alarm

0x00 = OFF, 0xFF = ON Default is 0x00 or off.Used to enable/disable door condition alarms for locks that support a door position sensor.Any lock that does not support DPS will always report 0x00.
Size: 1 Byte, Default Value: 0

Setting Description
-128 DPS Alarm On
0 DPS Alarm Off

Parameter 2: Auto Relock On/Off

0x00 = OFF, 0xFF = ON default is 0x00 or OFF
Size: 1 Byte, Default Value: 0

Setting Description
-128 Auto Relock On
0 Auto Relock Off

Parameter 20: Deadbolt Installed

0x00 = NO deadbolt , 0xFF = YES deadboltRead only parameter.Some locks contain optional deadbolt hardware.This parameter is used to determine if one is installed.
Size: 1 Byte, Default Value: 0

Setting Description
-128 Deadbolt No
0 Deadbolt Yes

Parameter 21: Eco Mode On/Off

0x00 = OFF, 0xFF = ON default is 0x00 or OFFIf supported switches lock to lower power mode of operation with reduced sound and led brightness.
Size: 1 Byte, Default Value: 0

Setting Description
-128 Eco Mode On
0 Eco Mode Off

Parameter 22: Privacy Mode with Deadbolt

0x00 = OFF, 0xFF = ON default is 0x00 or OFFIf enabled then extending the deadbolt will put the lock into Privacy Mode.
Size: 1 Byte, Default Value: 0

Setting Description
-128 Privacy Mode On
0 Privacy Mode Off

Parameter 23: Lock Body Alarms Mask

Each bit controls one alarm. 1 = alarm enabled, 0 = alarm disabled.0xFF = All Alarms on, Default is 0xFF.Bit 0: DPS Alarm (AX) (Duplicate of parameter 19. Values should be tied together)Bit 1: Deadbolt Alarm Bit 2: Lever Rotated (Rx)
Size: 1 Byte, Default Value: 0

Setting Description
0 DPS Alarm
1 Deadbolt Alarm
2 Lever Rotated

Parameter 3: Auto Relock Time

10 to 127 seconds default is 5 seconds
Size: 1 Byte, Default Value: 5

Setting Description
10 - 127 Seconds

Parameter 4: Wrong Code Entry Limit

3 to 10 default is 5 times
Size: 1 Byte, Default Value: 5

Setting Description
3 - 10 Times

Parameter 5: Language

Set the lock language. Default is 1= English
Size: 1 Byte, Default Value: 1

Setting Description
1 English Language
2 Spanish Language
3 French Language

Parameter 7: Shut Down Time (after wrong code entries)

10 to 127 seconds default is 60 seconds
Size: 1 Byte, Default Value: 60

Setting Description
10 - 127 Seconds

Parameter 8: Operating Mode

This sets the operating mode for the lock.
Size: 1 Byte, Default Value: 0

Setting Description
0 Normal Mode (Default)
1 Vacation Mode (Keypad Locked Out)
2 Privacy Mode (Keypad Locked, RF Unlock Functional)

Technical Data

Hardware Platform ZM5101
Device Type Door Lock - Keypad
Network Operation Listening Sleeping Slave
Firmware Version HW: 255 FW: 1.78:22.00
Z-Wave Version 6.51.07
Certification ID ZC10-18066161
Z-Wave Product Id 0x0129.0x8008.0x0A00
Outdoor Use ok
Door Lock Type Lever Handle
Firmware Updatable Updatable by Consumer by RF
IP (Ingress Protection) Rated ok
Supported Notification Types Access ControlPower Management
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoDoor Lock - Keypad