Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
1. Put the Z-Wave Controller into inclusion mode.2. Press the tamper switch 3 times within 1.5 seconds to put the unit into inclusion mode.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This presence detector using PIR (passive infrared receiver) detects the presence of a person in a room. The units compatible with S2 security, send information to a controller or any other associated Z-Wave device. Up to 4 devices can be controlled from this device. The sensor is a battery-powered device, which is in sleeping mode unless an action is detected. After a programmable sleeping time the device wakes up and sends a status information. After this the unit goes back to sleeping mode. Batteries can be changed without unscrewing the device from the door or frame. The unit will give a visual warning on the device and sends a warning to the Z-Wave controller, when batteries need to be replaced. The unit offers a tampering control and sends an alarm message when tampered.

Reset to factory default Please use this procedure only when the network primary controller is missing or otherwise inoperable.1. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode.2. Within 1 second of step 1, press the tamper switch again and hold until LED is off (about 5 seconds).3. Node ID is excluded. The device reverts to factory default state and will be in auto-inclusion mode for 4 minutes.
Inclusion 1. Put the Z-Wave Controller into inclusion mode.2. Press the tamper switch 3 times within 1.5 seconds to put the unit into inclusion mode.
Exclusion 1. Put the Z-Wave Controller into exclusion mode.2. Press the tamper switch 3 times within 1.5 seconds to put the unit into exclusion mode.
NIF XXXNIF
Wakeup After it has been included into a Z-Wave network, the detector will go to sleep but will send a Wakeup Notification Command periodically at preset period to the controller. The Motion detector will stay awake for 10 seconds at least and then go back to sleep to conserve battery life.The time interval between Wakeup Notification Commands can be set in the Wakeup Command Class based on the range values below:1) Minimum Wake Up Interval 600s (10 minutes)2) Maximum Wake Up Interval 86400s (1 day)3) Default Wake Up Interval 14400s (4 hours)4) Wake Up Interval Step Seconds 600s (10 minutes)
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline
2 4 PIR Control

Configuration Parameters

Parameter 1: Basic Set Level

When Basic Set Command is sent where contains a value, the receiver will take it for consideration; for instance, if a lamp module is received the Basic Set command of which value is decisive as to how bright of dim level of lamp module shall be.
Size: 1 Byte, Default Value: 99

Setting Description
1 - 99 Basic Set Level

Parameter 3: Sensitivity Level

In order to provide a best efficiency of the detector, it is recommended to test the detector with movements from a farthest end of the coverage area at first time of use.If movements cannot be detected sensitively, simply adjust the sensitivity level with Configuration Parameter #3. This parameter can be configured with the value of 1 through 10, where 1 means low sensitivity and 10 means highest sensitivity.
Size: 1 Byte, Default Value: 6

Setting Description
1 - 10 Sensitivity Level

Parameter 4: Re-trigger Interval

The Configuration parameter that can be used to adjust the interval of being re-triggered after the detector has been triggered as Configuration Parameter #4.No response will be made during this interval if a movement is presented.The time interval can be set between 5 secs to 3600 secs.
Size: 2 Byte, Default Value: 180

Setting Description
5 - 3600 Re-trigger Interval

Parameter 5: Lux Level

The user can set a detecting percentage of lux level which determines when the light sensor will be activated.If percentage of lux level of ambient illumination falls below this percentage, and a person moves across or within the protected area, the detector will emit Z-Wave ON Command (i.e. Basic Set Command (Value = Basic Set Level)) to controller and activate connected modules and lighting.Percentage can be set between 1% to 100%.
Size: 1 Byte, Default Value: 20

Setting Description
1 - 100 Lux Level

Parameter 6: On-Off Duration

The function of on-off duration setting will be useful if the detector is connected with a module or lighting.The duration determines how long the module/lighting should stay ON.For instance, Lamp Module turns off 100 secs after it has been turned on.This parameter can be configured with the value of 5 through 3600, where 5 means 5 second delay and 3600 means 3600 seconds of delay.
Size: 2 Byte, Default Value: 15

Setting Description
5 - 3600 On-Off Duration

Technical Data

Hardware Platform SD3502
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 1 FW: 1.00:00.05
Z-Wave Version 6.71.01
Certification ID ZC10-18066147
Z-Wave Product Id 0x0060.0x0001.0x0006
Color White
Supported Notification Types Home Security
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor