This is a
Add 4-in-1 Motion Sensorinto a Z-Wave network: a. Let the primary controller go into inclusion mode (If you dont know how to do this, refer to its manual).b. Short Press one time this Z-Button.c. The 4-in-1 Motion Sensor LED will blink, If the inclusion is successful, then LED will keep on 2 seconds. Otherwise, the LED will blink until timeout, in which case you need to repeat the process from step b.
The 4-in-1 motion sensor is designed for using with scenes in home automation systems, integrate motion, light, temperature and humidity sensors, powered by CR123A battery or MicroUSB cable. The Motion Sensor lets you know when movement is detected in a certain area and can trigger different actions in response to that movement (or lack of movement). It also lets you know the ambient temperature and humidity to trigger different actions to make you more comfort. This sensor integrated Z-Wave communication module to connect with Z-Wave gateway, and this device can be adapted to EU(868.42Mhz) or US(908.42MHz).
Reset to factory default | Reset 4-in-1 Motion Sensorto factory Default:1. Press and hold the Z-Button for 5 seconds.2. If holding time is more than 5 seconds, the LED will blink fast at acceleration. If reset success 4-in-1 Motion Sensor LED will turn off. When the Z-Button is released, it will send Device Reset Locally Command. Otherwise please repeat step 2.Note:1, This procedure should only be used when the primary controller is inoperable.2, Reset 4-in-1 Motion Sensor to factory default settings.It will set the 4-in-1 Motion Sensor to not in Z-Wave network state; delete the Association setting and restore the Configuration setting to the default. |
Inclusion | Add 4-in-1 Motion Sensorinto a Z-Wave network: a. Let the primary controller go into inclusion mode (If you dont know how to do this, refer to its manual).b. Short Press one time this Z-Button.c. The 4-in-1 Motion Sensor LED will blink, If the inclusion is successful, then LED will keep on 2 seconds. Otherwise, the LED will blink until timeout, in which case you need to repeat the process from step b. |
Exclusion | Remove 4-in-1 Motion Sensorfrom a Z-Wave network: a. Let the primary controller go into exclusion mode (If you dont know how to do this, refer to its manual).b. Short Press one time this Z-Button.c. The 4-in-1 Motion Sensor LED will keep on, If the remove is successful, then LED will blink 2 seconds. Otherwise, the LED will keep on until timeout, in which case you need to repeat the process from step b.Note: 4-in-1 Motion Sensor will go away Z-Wave SmartStart Inclusion when it is removed from a Z-Wave network. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline1. Notification Report.Sensor will send Notification Report when Motion Detection Unknown Location and (Event inactive).2. Multilevel Sensor ReportSensor will send Multilevel Sensor Report (Temperature, humidity, luminance) interval of 2 hours.3. Battery Report.Sensor will send Battery Report when the battery level is low and the battery reports value is 0xFF.4. Device Reset Locally. |
2 | 5 | Send Basic Set when PIR trigger |
Low Battery Power Level of alarm threshold values: the value range are 10~50 for percentage, so the Battery Low Power level can setting 10%~50%. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
10 - 50 | Low Battery Power Level of alarm threshold values |
Set 101 ~ 104 to default. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 255 | Set 101 ~ 104 to default. |
The interval time of sending the temperature reporting. if setting to 0 then the temperature reporting is disabled 1. Valid values: 0x00-0x28DE802. The minimum interval time is 1 minutes. For example, if the value is set to be more than 1 and less than 60, the interval time is 1 minutes, if the value is set to be more than 60 and less than 120, the interval time is 2 minutes. Size: 4 Byte, Default Value: 7200
Setting | Description |
---|---|
0 | the temperature reporting is disabled |
1 - 2678400 | The interval time of sending the temperature reporting is 31 days2678400 seconds |
The interval time of sending the humidity reporting. if setting to 0 then the humidity reporting is disabled 1. Valid values: 0x00-0x28DE802. The minimum interval time is 1 minutes. For example, if the value is set to be more than 1 and less than 60, the interval time is 1 minutes, if the value is set to be more than 60 and less than 120, the interval time is 2 minutes. Size: 4 Byte, Default Value: 7200
Setting | Description |
---|---|
0 | the luminance reporting is disabled |
1 - 2678400 | The interval time of sending the humidity reporting is 31 days2678400 seconds |
The interval time of sending the luminance reporting. if setting to 0 then the luminance reporting is disabled 1. Valid values: 0x00-0x28DE802. The minimum interval time is 1 minutes. For example, if the value is set to be more than 1 and less than 60, the interval time is 1 minutes, if the value is set to be more than 60 and less than 120, the interval time is 2 minutes. Size: 4 Byte, Default Value: 7200
Setting | Description |
---|---|
0 | the luminance reporting is disabled |
1 - 2678400 | The interval time of sending the luminance reporting is 31 days2678400 seconds |
The interval time of sending the battery level reporting. if setting to 0 then the battery level reporting is disabled 1. Valid values: 0x00-0x28DE802. The minimum interval time is 1 minutes. For example, if the value is set to be more than 1 and less than 60, the interval time is 1 minutes, if the value is set to be more than 60 and less than 120, the interval time is 2 minutes. Size: 4 Byte, Default Value: 86400
Setting | Description |
---|---|
0 | the battery level reporting is disabled |
1 - 2678400 | The interval time of sending the battery level reporting is 31 days2678400 seconds |
Enable 111 ~ 114 temperature/humidity/luminance/ battery level change reporting.0 = Unable1 = Enable Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unable |
1 | Enable |
Configuration temperature change threshold.Valid values: 1-500(unit 0.1) Size: 2 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 500 | the temperature change threshold value(unit 0.1) |
Configuration humidity change threshold.Valid values: 1-32(unit %) Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
1 - 32 | humidity change threshold value(unit %) |
Configuration luminance change threshold.Valid values: 1-65528(unit lx) Size: 2 Byte, Default Value: 150
Setting | Description |
---|---|
-32767 - -1 | luminance change threshold is 32767 to 65528 |
0 - 32766 | luminance change threshold is 0 to 32766 |
Configuration battery level change threshold.Valid values: 1-100(unit %) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 100 | battery level change threshold value(unit)% |
Turn on/off PIR 0x0A indicates the highest sensitivity, 0x00 means off PIR detection function. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 10 | 0x0A indicates the highest sensitivity, 0x00 means off PIR detection function. |
PIR triggers the waiting time value Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
0 | Unable |
1 | Enable |
Whether the BASIC SET command is sent after the PIR is triggered Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unable |
1 | Enable |
PIR triggers the correspondence between the value of the Basic set and the PIR state, When value is 0x00 PIR triggers Send the basic set command 0xff PIR alarm release send the basic set command 0x00, otherwise PIR triggers send the basic set command 0x00 PIR alarm release send the basic set command 0xff. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | PIR triggers Send the basic set command 0xff PIR alarm release send the basic set command 0x00 |
1 | PIR triggers send the basic set command 0x00 PIR alarm release send the basic set command 0xff. |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 3 FW: 0.10 |
Z-Wave Version | 6.81.00 |
Certification ID | ZC10-18066141 |
Z-Wave Product Id | 0x0384.0x0200.0x0009 |
Supported Notification Types | Access ControlLuminance |
Sensors | Air Temperature |
Firmware Updatable | Not Updatable |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |