This is a
Include/Exclude Button - Inclusion/exclusion, press 3 times in 2 seconds
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
This In-wall Power Monitor Switch is a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Mini-sized design makes it easy to place the In-wall Power Monitor Switch into the wall box and fit in the house decoration.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press the pairing button 3 times in 2 seconds and press and hold the pairing button for more than 5 seconds at the 3rd time.The module is excluded and restores to factory default setting.Then the module will be in auto-inclusion mode for 2 minutes.Please use this procedure only when the network primary controller is missing or otherwise inoperable.The Device Reset Locally Command Class is used to notify central controllers that a Z-Wave device is resetting its network specific parameters.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | u0022Lifelineu0022Reports the device status and allows for assigning single device only (main controller by default). |
2 | 5 | alarm EP 1It is assigned to switch connected to the S1 terminal (uses Notification command class) |
3 | 5 | Switch 1It is assigned to switch connected to the S1 terminal (uses Basic command class) |
4 | 5 | alarm EP 2It is assigned to switch connected to the S1 terminal (uses Notification command class) |
5 | 5 | Switch 2It is assigned to switch connected to the S1 terminal (uses Basic command class) |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
0 : Disable (Default)1~32767 : Time in second that the O2 will turn off automatically. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 - 32767 | D1 automatically time |
0 : Disable (Default)1~32767: Time in second that the O2 will turn off automatically. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 - 32767 | D2 automatically time |
0 : Toggle switches (Default)1 : Toggle switches with memory2 : Momentary switch Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 2 | switch type |
0 : device does not memorize its status at power cut. Load is disconnected (Default)1 : device memorizes its status at the power cut.Load will be set to the status from before power cut. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Reload power status |
0 : Disabled1~100 : 1 % ~ 100 %. (Default = 10%) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 | Disble |
1 - 100 | change rate |
0 : Disabled60~32767Seconds. (Default = 300 Seconds) Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 | Disable |
60 - 32767 | Watts auto-report period |
0 : DisabledSet time interval of reporting KWH (60 ~32767) in seconds. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
0 | Disable |
60 - 32767 | KWH auto-report period |
0 : Disable (Default)1~32767 : Time in second that the O2 will turn on automatically. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 - 32767 | D1 automatically turn on |
0 : Disable (Default)1~32767: Time in second that the O2 will turn on automatically. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 - 32767 | D2 automatically turn on |
Hardware Platform | ZM5101 |
Device Type | Power Strip |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 2.05 |
Z-Wave Version | 6.81.00 |
Certification ID | ZC10-18066136 |
Z-Wave Product Id | 0x0068.0x0003.0x0015 |
Supported Meter Type | Electric Energy |
Firmware Updatable | Updatable by Manufacturer |
Loads Controlled | 2 |
Switch Type | Toggle |
Supported Notification Types | Power Management |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |