Quickstart

This is a secure Wall Controller for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).2. Make sure the wall controller does not belong to any Z-Wave network (please refer to the part How to check whether the wall controller included to a network of this manual).3. Short press the inclusion/exclusion button, or press and hold down ALL ON/OFF button for over 3 seconds, the wall controller will be set to inclusion mode, and waiting to be included, then LED indicator turns on and blinks 6 times quickly to indicate successful inclusion.Once the wall controller quits inclusion mode, the LED indicator will turns off. There are 3 methods for the wall controller to quit inclusion mode:1. Automatically quits after successful inclusion.2. Quits after 25 seconds timeout.3. Press and hold down ALL ON/OFF button for over 3 seconds, or short press the inclusion/exclusion button to quit.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The Wall controller is a Security Enabled Z-Wave Plus device that can both control other Z-Wave devices and activate scenes in Gateways. The wall controller can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All nonbattery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Reset to factory default Press and hold down inclusion/exclusion button for over 8 seconds, LED indicator blinks slowly to indicate successful factory reset, release inclusion/exclusion button, the wall controller will restart automatically.Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable.
Inclusion 1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).2. Make sure the wall controller does not belong to any Z-Wave network (please refer to the part How to check whether the wall controller included to a network of this manual).3. Short press the inclusion/exclusion button, or press and hold down ALL ON/OFF button for over 3 seconds, the wall controller will be set to inclusion mode, and waiting to be included, then LED indicator turns on and blinks 6 times quickly to indicate successful inclusion.Once the wall controller quits inclusion mode, the LED indicator will turns off. There are 3 methods for the wall controller to quit inclusion mode:1. Automatically quits after successful inclusion.2. Quits after 25 seconds timeout.3. Press and hold down ALL ON/OFF button for over 3 seconds, or short press the inclusion/exclusion button to quit.
Exclusion There are two exclusion methods:Method 1: Exclusion from the primary controller/gateway as follows:1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).2. Short press the inclusion/exclusion button, or press and hold down ALL ON/OFF button for over 3 seconds, the wall controller will be set to exclusion mode, and waiting to be excluded, then LED indicator turns on and shows 3 short blinks and 1 long blink to indicate successful exclusion.Once the wall controller quits exclusion mode, the LED indicator will turns off. There are 3 methods for the wall controller to quit exclusion mode:1. Automatically quits after successful exclusion.2. Quits after 25 seconds timeout.3. Press and hold down ALL ON/OFF button for over 3 seconds, or short press the inclusion/exclusion button to quit.Method 2: Factory reset the wall controller will force the wall controller to be excluded from a network. (please refer to the part Factory Reset of this manual)
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 1. Send Command Class Device Reset Locally to associated devices of this group to report factory reset information when factory reset the wall controller.2. Double click a group number of the wall controller to send command toassociated devices of this group using Command Class Central Scene.
2 12 Press button u00221u0022 to activate group.1.Press and hold down button u00221u0022 to switch the associated devices with Basic Set commands.2.Press brightness value buttons(or the dim wheel around the central button) direct control of associated devices using the Multilevel Switch Set commands.3.Short press Scene button S1/S2/S3, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 /0x20 / 0x30.4.Press and hold down Scene button S1/S2/S3, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20 / 0x30.
3 12 Press button u00222u0022 to activate group.1.Press and hold down button u00222u0022 to switch the associated devices with Basic Set commands.2.Press brightness value buttons(or the dim wheel around the central button) direct control of associated devices using the Multilevel Switch Set commands.3.Short press Scene button S1/S2/S3, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20 / 0x30.4.Press and hold down Scene button S1/S2/S3, direct control of associated devices using Scene Conf Set, Scene ID= 0x10 / 0x20 / 0x30.
4 12 Press button u00223u0022 to activate group.1.Press and hold down button u00223u0022 to switch the associated devices with Basic Set commands.2.Press brightness value buttons(or the dim wheel around the central button) direct control of associated devices using the Multilevel Switch Set commands.3.Short press Scene button S1/S2/S3, direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20 / 0x30.4.Press and hold down Scene button S1/S2/S3, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20 / 0x30.

Technical Data

Hardware Platform ZM5101
Device Type Wall Controller
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.10
Z-Wave Version 6.71.01
Certification ID ZC10-18066130
Z-Wave Product Id 0x0330.0x0301.0xA109
Z-Wave Scene Type Central Scene
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoWall Controller