This is a
Press once TriSensors Action Button. If it is the first installation, the yellow LED will keep solid until whole network processing is complete. If successful, the LED will flash white -> green -> white -> green, after 2 seconds finished. If failed, the yellow LED lasts for 30 seconds, then the green LED flashes once.If it is the S2 encryption network, please enter the first 5 digits of DSK.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Aeotec TriSensor is a universal Z-Wave Plus compatible product, consists of temperature, lighting and motion sensors, powered by a CR123A battery. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. By the built-in motion sensor, an alam will be sent to the gateway when the motion sensor is triggered.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
1.Power up the device.2.Press and hold the button for 15s until Red Led is blinking,then release the button. Note: Please use this procedure only when the network primary controller is missing or otherwise inoperable.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: Press and hold the button at least 2s until Red Led is on and then release the button,device will send wakeup notification to controller if device is in a Z-Wave network.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Group 1 is lifeline group; all nodes which associated in this group will receive the messages sent by device throughlifeline.CommandClass:COMMAND_CLASS_NOTIFICATION COMMAND_CLASS_SENSOR_BINARY COMMAND_CLASS_SENSOR_MULTILEVEL COMMAND_CLASS_BATTERY COMMAND_CLASS_DEVICE_RESET_LOCALLYCommand:NOTIFICATION_REPORTSENSOR_BINARY_REPORT SENSOR_MULTILEVEL_REPORT BATTERY_REPORT DEVICE_RESET_LOCALLY_NOTIFICATION |
2 | 5 | Group 2 is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects a movement event. Basic Set Value is decided by Configuration Parameter 6.CommandClass:COMMAND_CLASS_BASIC (HomeSecurity)Command:BASIC_SET |
3 | 5 | Group 3 is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects an ambient temperature alarm (Decided by Configuration Parameter 7).CommandClass:COMMAND_CLASS_BASIC(Temperature)Command:BASIC_SET |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
This parameter is configured the delay time before PIR sensor can be triggered again to reset motion timeout counter. Value = 0 will disable PIR sensor from triggering until motion timeout has finished. Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
0 - 32767 | Value = 0 will disable PIR sensor from triggering until motion timeout has finished. |
This parameter is configured the Led light on disable or enable. 1Enable Led Blink when device detects a motion event.0Disable Led Blink. This configuration is not affect inclusion, exclusion and reset. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 1Enable Led Blink when device detects a motion event. 0Disable Led Blink. This configuration is not affect inclusion, exclusion and reset. |
This configuration defines the calibrated scale for ambient light intensity. Because the method and position that the sensor mounted and the cover of sensor will bring measurement error, user can get more real light intensity by this parameter setting. User should run the steps as blows for calibrating1)Set this parameter value to default (Assumes the sensor has been added in a Z- Wave Network).2)Place a digital luxmeter close to sensor and keep the same direction, monitor the light intensity value (Vm) which report to controller and record it. The same time user should record the value (Vs) of luxmeter.3)The scale calibration formula: k = Vm / Vs.4)The value of k is then multiplied by 1024 and rounded to the nearest whole number.5)Set the value getting in 5) to this parameter, calibrate finished. For example, Vm = 300, Vs =2600, then k = 2600 /300 = 8.6667 k = 8.6667 * 1024 = 8874.78875The parameter should be set to 8875. Size: 2 Byte, Default Value: 1024
Setting | Description |
---|---|
1 - 32767 | Scale: Lux. |
0Disable.1Red.2 Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 8 | 0Disable.1Red. 2Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange. |
0Disable.1Red.2 Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 8 | 0Disable.1Red. 2Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange. |
0Disable.1Red.2 Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 8 | 0Disable. 1Red. 2 Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange. |
0Disable.1Red.2 Green.3Blue.4Yellow.5Pink.6Cyan.7Purple.8Orange. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 8 | 0Disable. 1Red. 2 Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange. |
This parameter is configured the time to clear motion event after a motion event detected. Time to motion clear, the device will send a clear event report to controller and send BASIC_SET= 0x00 to nodes associated in group 2. Unit: Second. Size: 2 Byte, Default Value: 240
Setting | Description |
---|---|
1 - 32767 | Unit: Second. |
Configure temperature sensor scale type, Temperature to report in Celsius or Fahrenheit. 0Celsius (C).1Fahrenheit (F). Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 8 | 0Disable. 1Red. 2 Green. 3Blue. 4Yellow. 5Pink. 6Cyan. 7Purple. 8Orange. |
0 - 1 | 0Celsius (C). 1Fahrenheit (F). |
Change threshold value for change in temperature to induce an automatic report for temperature sensor. Scale is identical setting in Parameter No.20.Setting of value 20 can be a change of -2.0 or +2.0 (C or F depending on Parameter No.20) to induce automatic report or setting a value of 2 will be a change of 0.2(C or F). Size: 2 Byte, Default Value: 20
Setting | Description |
---|---|
0 - 250 | Temperature Threshold Value |
Change threshold value for change in light sensor to induce an automatic report for temperature sensor. Scale: Lux. Size: 2 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 10000 | Scale: Lux. |
This parameter is configured the time interval for temperature sensor report. This value is larger, the battery life is longer. And the temperature value changed is not obvious.Unit: Second. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
1 - 32767 | Unit: Second. |
This parameter is configured the time interval for light sensor report. This value is larger, the battery life is longer. And the light intensity changed is not obvious.Unit: Second. Size: 2 Byte, Default Value: 3600
Setting | Description |
---|---|
1 - 32767 | Unit: Second. |
This parameter is configured the sensitivity that motion detect. 0PIR sensor disabled.1Lowest sensitivity. 11 Highest sensitivity. Size: 1 Byte, Default Value: 11
Setting | Description |
---|---|
0 - 11 | 0PIR sensor disabled. 1Lowest sensitivity.11 Highest sensitivity. |
The current measuring temperature value can be add and minus a value by this setting. The scale can be decided by Parameter Number 20.Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit) Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-200 - 200 | Temperature Offset Value = [Value] * 0.1(Celsius / Fahrenheit) |
The current measuring light intensity value can be add and minus a value by this setting. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
-1000 - 1000 | Scale: Lux. |
0 Disable sensor binary report when motion event is detected or cleared. 1 Enable sensor binary report when motion event is detected or cleared. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0 Disable sensor binary report when motion event is detected or cleared. 1 Enable sensor binary report when motion event is detected or cleared. |
This parameter is configured the enabled or disabled send BASIC_SET command to nodes that associated in group 2 and group 3.0Disabled All Group Basic Set Command1Enabled Group 2 Basic Set Command, Group 3 Basic Set Command is disabled. 2Enabled Group 3 Basic SetCommand, Group 2 Basic Set Command is disabled. 3Enabled Group 2 and Group 3 Basic Set Command. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 - 3 | 0Disabled All Group Basic Set Command 1Enabled Group 2 Basic Set Command, Group 3 Basic Set Command is disabled. 2Enabled Group 3 Basic SetCommand, Group 2 Basic Set Command is disabled. 3Enabled Group 2 and Group 3 Basic Set Command. |
0Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0x00 to devices associated in group 2 when motion event is cleared.1 Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0xFF to devices associated in group 2 when motion event is cleared.2Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered.3Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered.4Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is cleared. 5Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is cleared. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 5 | 0Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0x00 to devices associated in group 2 when motion event is cleared. 1 Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered, send BASIC_SET = 0xFF to devices associated in group 2 when motion event is cleared. 2Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is triggered. 3Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is triggered. 4Send BASIC_SET = 0x00 to devices associated in Group 2 when motion event is cleared. 5Send BASIC_SET = 0xFF to devices associated in Group 2 when motion event is cleared. |
This parameter is configured the threshold value that alarm level for temperature. When the current ambient temperature value is larger than this configuration value, device will send a BASIC_SET = 0xFF to nodes associated in group 3. If current temperature value is less than this value, device will send a BASIC_SET = 0x00 to nodes associated in group 3.Value = [Value]0.1(Celsius / Fahrenheit) Size: 2 Byte, Default Value: 239
Setting | Description |
---|---|
-400 - 850 | Value = [Value]0.1(Celsius / Fahrenheit) |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 17 FW: 2.07:01.32 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18056127 |
Z-Wave Product Id | 0x0371.0x0202.0x0005 |
Sensors | Air TemperatureLuminanceMotion/No Motion (Binary) |
Supported Notification Types | Home Security |
Color | White |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |