Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Add for inclusion: 1).Insert the battery.2).Set the Z-Wave network main controller into learning mode.3).Triggering this action button.4).If the add for inclusion is successful, the LED will blink fast and then keep on 3 seconds. Otherwise, the LED will blink 25 seconds and then turn off, in which case you need to repeat the process from step



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Well design to match your door/window installation Firmware Wireless update Low voltage alarm to remind changing battery Easy installation by screws or 3M adhesive tape.

Reset to factory default LED will blink fast for 5 seconds and then keep solid for 3 seconds, after that Door/Window Sensor will send Device_Reset_Locally to the main controller and exclude from the Z-Wave network.Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion Add for inclusion: 1).Insert the battery.2).Set the Z-Wave network main controller into learning mode.3).Triggering this action button.4).If the add for inclusion is successful, the LED will blink fast and then keep on 3 seconds. Otherwise, the LED will blink 25 seconds and then turn off, in which case you need to repeat the process from step
Exclusion Remove for exclusion;1.Insert the CR battery.2.Set the Z-Wave network main controller into exclusion mode.3.Triggering this action button.If the remove for exclusion is successful, the LED will blink fast and turn off. Otherwise, the LED will keep solid for 2 seconds and then turn off, in which case you need to repeat the process from step 2.
NIF XXXNIF
Wakeup 1. Short press 3 time.2. LED will blink one time; sending wake up notification cc
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 1. Notification Report.Sensor will send Notification Report when the supported event is triggered.2. Battery Report.Sensor will send Battery Report when the battery level is low and the battery reports value is 0xFF.3. Device Reset Locally.
2 5 1.Basic SetSensor will send Basic Set when the sensor body and magnet removed or combined.

Configuration Parameters

Parameter 10: Level of low battery

This parameter defines a battery level as the low battery.
Size: 1 Byte, Default Value: 10

Setting Description
0 - 50 %

Parameter 14: Enable/Disable BASIC SET command

Door/Window Sensor can send BASIC SET command to nodes associated with group 2
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable
1 Enable

Parameter 15: Value of the BASIC SET

Door/Window Sensor can reverse its value of BASIC SET when the magnet is triggered.
Size: 1 Byte, Default Value: 0

Setting Description
0 Send BASIC SET VALUE = 255 to nodes associated with group 2 when door/window is opened.Send BASIC SET VALUE = 0 to nodes associated with group 2 when door/window is closed.
1 Send BASIC SET VALUE = 0 to nodes associated with group 2 when door/window is opened.Send BASIC SET VALUE = 255 to nodes associated with group 2 when door/window is closed.

Parameter 254: Enable/disable the configuration command

Lock/unlock all configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock
1 Lock

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 32 FW: 1.08
Z-Wave Version 6.71.01
Certification ID ZC10-18056126
Z-Wave Product Id 0x0384.0x0200.0x0008
Supported Notification Types Access ControlHome Security
Sensors Open/Closed (Binary)
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoNotification Sensor