Quickstart

This is a secure Wall Controller for CEPT (Europe). To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).2. Make sure the wall controller does not belong to any Z-Wave network (please refer to the part How to check whether the wall controller included to a network of this manual).3. Short press the inclusion/exclusion button, or press and hold down ALL ON/OFF button for over 3 seconds, the wall controller will be set to inclusion mode, and waiting to be included, then LED indicator turns on and blinks 6 times quickly to indicate successful inclusion.Once the wall controller quits inclusion mode, the LED indicator will turns off. Thereare 3 methods for the wall controller to quit inclusion mode:1. Automatically quits after successful inclusion.2. Quits after 25 seconds timeout.3. Press and hold down ALL ON/OFF button for over 3 seconds, or short press theinclusion/exclusion button to quit.

Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.


Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.

What is Z-Wave?

Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.

Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.

This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.

If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.

For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.

Product Description

The Wall controller is a Security Enabled Z-Wave Plus device that can both control other Z-Wave devices and activate scenes in Gateways. The wall controller can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All nonbattery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Prepare for Installation / Reset

Please read the user manual before installing the product.

In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.

Reset to factory default

This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.

Press and hold down inclusion/exclusion button for over 8 seconds, LED indicator will blink slowly to indicate successful factory reset, release inclusion/exclusion button,the wall controller will restart automatically.Please use this procedure only when the network primary controller is missing or otherwise inoperable.

Safety Warning for Mains Powered Devices

ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.

Inclusion/Exclusion

On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.

Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.

Inclusion

1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).2. Make sure the wall controller does not belong to any Z-Wave network (please refer to the part How to check whether the wall controller included to a network of this manual).3. Short press the inclusion/exclusion button, or press and hold down ALL ON/OFF button for over 3 seconds, the wall controller will be set to inclusion mode, and waiting to be included, then LED indicator turns on and blinks 6 times quickly to indicate successful inclusion.Once the wall controller quits inclusion mode, the LED indicator will turns off. Thereare 3 methods for the wall controller to quit inclusion mode:1. Automatically quits after successful inclusion.2. Quits after 25 seconds timeout.3. Press and hold down ALL ON/OFF button for over 3 seconds, or short press theinclusion/exclusion button to quit.

Exclusion

There are two exclusion methods:Method 1: Exclusion from the primary controller/gateway as follows:1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).2. Short press the inclusion/exclusion button, or press and hold down ALL ON/OFF button for over 3 seconds, the wall controller will be set to exclusion mode, and waiting to be excluded, then LED indicator turns on and shows 3 short blinks and 1 long blink to indicate successful exclusion.Once the wall controller quits exclusion mode, the LED indicator will turns off. There are 3 methods for the wall controller to quit exclusion mode:1. Automatically quits after successful exclusion.2. Quits after 25 seconds timeout.3. Press and hold down ALL ON/OFF button for over 3 seconds, or short press the inclusion/exclusion button to quit.Method 2: Factory reset the wall controller will force the wall controller to be excluded from a network. (please refer to the part Factory Reset of this manual)Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable.

Quick trouble shooting

Here are a few hints for network installation if things dont work as expected.

  1. Make sure a device is in factory reset state before including. In doubt exclude before include.
  2. If inclusion still fails, check if both devices use the same frequency.
  3. Remove all dead devices from associations. Otherwise you will see severe delays.
  4. Never use sleeping battery devices without a central controller.
  5. Dont poll FLIRS devices.
  6. Make sure to have enough mains powered device to benefit from the meshing

Association - one device controls an other device

Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.

Association Groups:

Group Number Maximum Nodes Description
1 1 1. Send Command Class Device Reset Locally to associated devices of this group to report factory reset information when factory reset the wall controller.2. Double click a group number of the wall controller to send command toassociated devices of this group using Command Class Central Scene.
2 12 1. Press and hold down button u00221u0022 to activate group in order to switch the associated devices with a Basic Set or dim these devices by using the two brightness buttons or adjust color temperature by using color wheel.2. Short press Scene button S1/S2/S3/S4,direct control of associated devices using Scene Activation Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.3. Press and hold down Scene button S1/S2/S3/S4, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.
3 12 1. Press and hold down button u00222u0022 to activate group in order to switch theassociated devices with a Basic Set or dim these devices by using the twobrightness buttons or adjust color temperature by using color wheel.2. Short press Scene button S1/S2/S3/S4, direct control of associateddevices using Scene Activation Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.3. Press and hold down Scene button S1/S2/S3/S4, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.
4 12 1. Press and hold down button u00223u0022 to activate group in order to switch theassociated devices with a Basic Set or dim these devices by using the twobrightness buttons or adjust color temperature by using color wheel.2. Short press Scene button S1/S2/S3/S4, direct control of associateddevices using Scene Activation Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.3. Press and hold down Scene button S1/S2/S3/S4, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.
5 12 1. Press and hold down button u00224u0022 to activate group in order to switch theassociated devices with a Basic Set or dim these devices by using the twobrightness buttons or adjust color temperature by using color wheel.2. Short press Scene button S1/S2/S3/S4, direct control of associateddevices using Scene Activation Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.3. Press and hold down Scene button S1/S2/S3/S4, direct control of associated devices using Scene Conf Set, Scene ID = 0x10 / 0x20 / 0x30 / 0x40.

Technical Data

Hardware Platform ZM5101
Device Type Wall Controller
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.10
Z-Wave Version 6.71.01
Certification ID ZC10-18056125
Z-Wave Product Id 0x0330.0x0300.0xa103
Firmware Updatable Updatable by Consumer by RF
Z-Wave Scene Type Scene & Central Scene
Security V2 S2_UNAUTHENTICATED
Frequency XXfrequency
Maximum transmission power XXantenna

Supported Command Classes

Controlled Command Classes

Explanation of Z-Wave specific terms