This is a
1.Insert the battery.2.Set the Z-Wave network main controller into Inclusion mode.3.Triggering this button action.4.If the add for inclusion is successful, the LED will blink fast and then keep on 3 seconds. Otherwise, the LED will blink 25 seconds and then turn off, in which case you need to repeat the process from step 2.
It alerts you with a built-in siren when water is detected Low voltage alarm to remind changing batteryEasy to set up and use Universally applicable: universally applicable in every place and circumstances.
Reset to factory default | Pressing and holding the z-button for 5 seconds, LED will blink for 5 seconds and then keep solid for 3 seconds, after that Water Leak Sensor will send Device_Reset_Locally to the main controller and exclude from the Z-Wave network.Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. |
Inclusion | 1.Insert the battery.2.Set the Z-Wave network main controller into Inclusion mode.3.Triggering this button action.4.If the add for inclusion is successful, the LED will blink fast and then keep on 3 seconds. Otherwise, the LED will blink 25 seconds and then turn off, in which case you need to repeat the process from step 2. |
Exclusion | 1.Insert the battery.2.Set the Z-Wave network main controller into exclusion mode.3.Triggering this button action.If the remove for exclusion is successful, the LED will blink fast and turn off. Otherwise, the LED will keep solid for 25 seconds and then turn off, in which case you need to repeat the process from step 2. |
NIF | XXXNIF |
Wakeup | Short press the z-button 3 times within 1 second.LED will blink once, and Sensor will send wake up notification to wake the device up. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline1. Notification Report.Sensor will send Notification Report when the water probe is triggered.2. Battery Report.Sensor will send Battery Report when the battery level is low and the battery reports value is 0xFF.3. Device Reset Locally. |
2 | 5 | 1.Basic SetSensor will send Basic Set when the water probe is triggered. |
This parameter defines a battery level as the low battery. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
10 - 50 | when the battery level is less than this value, device will send low battery report to the gateway |
beeping rate when the water probe is triggered Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | buzzer keep on 1s, off 1s |
1 | buzzer keep on 0.5s, off 0.5s |
2 | buzzer keep on beeping always |
3 | buzzer keep silence |
Lock/unlock all configuration parameters. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | unlock |
1 | lock |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.09 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18056119 |
Z-Wave Product Id | 0x0384.0x0200.0x000a |
Sensors | Water Flow |
Firmware Updatable | Updatable by Consumer by RF |
Supported Notification Types | Water Alarm |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |