This is a
1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).2. Power on the in-wall dimmer and set it into inclusion mode. There are two methods to set the in-wall dimmer into inclusion mode:1)Repower on the dimmer, it will be set into inclusion mode automatically, and waiting to be included.2)Triple press the action button on the dimmer, it will set the plug into inclusion mode.The connected light will stay solid on for 3 seconds to indicate successful inclusion.
The in-wall dimmer is a Z-Wave device that is used to switch ON/OFF and adjust light intensity of the connected light and can be controlled by other Z-Wave devices. The Inwall Dimmer can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non- battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Reset to factory default | Press and hold down the action button for over 10 seconds, the dimmer will be reset to factory defaults.Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable. |
Inclusion | 1. Set primary controller/gateway into inclusion mode (Please refer to your primary controllers manual on how to turn your controller into inclusion).2. Power on the in-wall dimmer and set it into inclusion mode. There are two methods to set the in-wall dimmer into inclusion mode:1)Repower on the dimmer, it will be set into inclusion mode automatically, and waiting to be included.2)Triple press the action button on the dimmer, it will set the plug into inclusion mode.The connected light will stay solid on for 3 seconds to indicate successful inclusion. |
Exclusion | There are two exclusion methods:Method 1: Exclusion from the primary controller/gateway as follows:1. Set the primary controller/gateway into exclusion mode (Please refer to your primary controllers manual on how to set your controller into exclusion).2. Triple press the action button, the dimmer will be set to exclusion mode, and waiting to be excluded, then the dimmer will be included to the network.Method 2: Factory reset the dimmer will force the it to be excluded from a network.(please refer to the part Factory Reset of this manual)Note: Factory reset is not recommended for exclusion, please use this procedure only if the primary controller/gateway is missing or otherwise inoperable. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | 1. When factory reset the dimmer, send u0022Device Reset Locally Notification CCu0022 to associated devices of this group to report factory reset information.2. When load state changes, send u0022Basic Report CCu0022 to associated devices of this group.3. When a load malfunction is detected, send u0022Emergency shutoff statusu0022 to Lifeline. |
Saving load state before power failure Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | shutoff load |
1 | turn on load |
2 | save load state before power failure |
Enable/disable to send the basic report to the Lifeline when the load state changed (When value set as 1, re-power on the dimmer, it will send Basic report automatically Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable to send Basic report |
1 | Enable to send Basic report |
Default fade time (unit is second, this value has the same function as Duration of Multilevel) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Instantly |
1 - 127 | 1 second (0x01) to 127 seconds (0x7F) in 1 second resolution. |
128 - 254 | 1 minute (0x80) to 127 minutes (0xFE) in 1 minute resolution. |
255 | Factory default duration. 1 second |
Setting minimum brightness value Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 50 | the bigger the value is, the higher the loads minimum brightness is |
Choose MOSFET driving type Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | trailing edge |
1 | leading edge |
Enable/disable external switch to be added to and removed from a network (when enables this function, triple press the external switch within 1.5 seconds to be added to or removed from a network) Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | disable |
1 | enable |
Hardware Platform | ZM5101 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18056100 |
Z-Wave Product Id | 0x0330.0x021A.0xD005 |
Supported Notification Types | System |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | Russia - 868.4MHz, 869.85MHz |
Maximum transmission power | 5 mW |