This is a
For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZD2105 to your controller. To get in the inclusion mode, the distance between sensor and controller is suggested to be in one meter. Press the program switch of ZD2105 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZD2105 will go to sleep after 20 seconds.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The ZD2105-5 Door and Window sensor is used in any Z-Wave network to detect the opening or closing of a door or window.Special Design can fit most of door/window frame.The primary sensing element is a magnetic reed switch, the ZD2105-5 is supplied with the sensor, sensor mounting bracket and the trigger magnet.An additional set of sensor inputs are provided through a 2 position screw terminal and can be used to expand the sensor capability to multiple inputs.The ZD2105-5 is powered by 2 x AAA Battery (supplied with unit, battery life is more than 2 years) and is intended for indoor use only. The ZD2105-5 features tamper proof switch, low battery warning and can be firmware updated over the air.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Factory Default Reset: Trigger the rear cover switch to send the Alarm Report and trigger the reed switch (close & open) 5 times in 10 seconds, ZD2105 will send the Device Reset Locally Notification command and reset to the factory default.(Remark: This is to be used only in the case of primary controller being inoperable or otherwise unavailable.)
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: Press program switch to send the NIF and after 3 seconds to send Wake Up Notification for receiving all the command class from controller.If ZD2105 received Wake Up No More Information command then the ZD2105 will go to sleep mode or it will wait 10 seconds then go sleep mode. It will proceed all the commands after sending the Wake Up Notification
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | * Group 1 = Lifeline |
2 | 5 | * Group 2 = On/Off Control |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 24.01 |
Z-Wave Version | 6.81.00 |
Certification ID | ZC10-18036070 |
Z-Wave Product Id | 0x0109.0x2022.0x2202 |
Color | White |
Sensors | Open/Closed (Binary) |
Outdoor Use | ok |
Supported Notification Types | Access Control |
Security V2 | S2_UNAUTHENTICATED ,S2_AUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |