This is a
Includeddevice:1. Insert the LIR2450 battery.2. Set the Z-Wave network main controller into learning mode( see Z-Wave network controller operating manual).3. Pressing and holding the button for 3 seconds.4. If the inclusion is successful, the LED will blink in green less than for 5 seconds and then keep on for 15 seconds.
The NanoMote One is a wireless, portable and rechargeable scene switch. It can control a Z-Wave device, such as smart plug, smart dimmer with a Z-Wave gateway. You can also activate a scene like sleep scene, movie scene and entertainment scene with it.
Reset to factory default | Pressing and holding the button for 20 seconds. Release the button after 20 seconds, LED will keep in yellow for 3 seconds. Scene Controller will be reset to factory defaults if you short press the button within this 3 seconds.Using this procedure only in the event that the network primary controller is missing or otherwise inoperable. |
Inclusion | Includeddevice:1. Insert the LIR2450 battery.2. Set the Z-Wave network main controller into learning mode( see Z-Wave network controller operating manual).3. Pressing and holding the button for 3 seconds.4. If the inclusion is successful, the LED will blink in green less than for 5 seconds and then keep on for 15 seconds. |
Exclusion | To remove the NanoMote One from the Z-Wave network:(1) Insert the LIR2450 battery.(2) Set the Z-Wave network main controller into remove mode(see Z-Wave controller operating manual).(3) Triple click the button, if the exclusion is successful, LEDwill blink in orange for less than 5 seconds and then keep onfor 3 seconds. |
NIF | XXXNIF |
Wakeup | Pressing and holding Button for 3 seconds. Led will turn to green,which means Scene Controller has been woken up. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Scene Controller will send Scene Controller sends the central scene notification command and battery report command to the associated nodes. |
2 | 5 | Scene Controller will send Basic Set command to the associated nodes. |
3 | 5 | Scene Controller will sendswitch multilevel set, the multilevel start level change and multilevel stop level change command to the associated nodes. |
Define a battery level as the low battery. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
10 - 50 | Define a battery level as the low battery. |
Enable send central scene notification. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | when value is 0, it can not be send scene notification;when the value is 1,it can be send central scene notification. |
set the value of the command switch multilevel Size: 1 Byte, Default Value: 255
Setting | Description |
---|---|
-128 - 127 | The higher the value, the longer the duration value of the command. |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | When value is 1,it will can allow the buzzer when battery is running low;When value is 0,it will can not allow the buzzer when battery is running low |
Hardware Platform | ZM5101 |
Device Type | Wall Controller |
Network Operation | Portable Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18036040 |
Z-Wave Product Id | 0x0371.0x0102.0x0004 |
Z-Wave Scene Type | Central Scene |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |