This is a
1. Have Z-WaveTM Controller enter inclusion mode.2. Pressing tamper key three times within 1.5 secondswill enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller, about 20 seconds
The slim multisensor PST02-1C has door/window, temperature and illumination, 3 sensors function in one,based on Z-Wave technologyIt is the Z-WaveTM plus product, it support the security, OTA... Thosenewest features of the Z-WaveTM technology. Z-WaveTM is a wirelesscommunication protocol designed for home automation, specifically toremotely control applications in residential and light commercialenvironments. The technology uses a low-power RF radio embedded orretrofitted into home electronics devices and systems, such as lighting,home access control, entertainment systems and household appliances.
Reset to factory default | Notice: Use this procedure only in the eventthat the primary controller is lost or otherwise inoperable.1. Pressing tamper key four times within 1.5 seconds and do not release the tamper key on the 4th press, the LED lite will ON.2. After 3 seconds the LED will turn OFF, after that within 2 seconds, release the tamper key. If successful, the LED will light ON one second.Otherwise, the LED will flash once.3. IDs are excluded and all settings will reset to factory default. |
Inclusion | 1. Have Z-WaveTM Controller enter inclusion mode.2. Pressing tamper key three times within 1.5 secondswill enter the inclusion mode.3. After add successful, the device will wake to receive the setting command from Z-WaveTM Controller, about 20 seconds |
Exclusion | 1. Have Z-WaveTM Controller enter exclusion mode.2. Pressing tamper key three times within 1.5 seconds will enter the exclusion mode.Node ID has been excluded. |
NIF | XXXNIF |
Wakeup | After the device adding to the network, it will wake-up once per day indefault. When it wakes-up it will broadcast the Wake Up Notificationmessage to the network, and wake-up 10 seconds to receive thesetting commands.The wake-up interval minimum setting is 30 minutes, and maximumsetting is 120 hours. And the interval step is 30 minutes.If the user want to wake-up the device immediately, please remove thefront cover, and press the tamper key once. The device will wake-up 10seconds. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | The group 1 is forreceiving the report message, like triggered event,temperature, illumination etc. |
2 | 8 | The group 2 is for lightcontrol, the device will send the Basic Set commandto this group. |
The interval time for auto report thebattery level.0 means turn off auto report battery.The default value is 12. The tick timecan setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the battery level. 0 means turn off auto report battery. The default value is 12. The tick time can setting by the configuration No.20. |
The interval time for auto report thedoor/window state.0 means turn off auto reportdoor/window state.The default value is 12. The tick timecan setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the door/window state. 0 means turn off auto report door/window state. The default value is 12. The tick time can setting by the configuration No.20. |
The interval time for auto report theillumination.0 means turn off auto reportillumination.The default value is 12. The tick timecan setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the illumination. 0 means turn off auto report illumination. The default value is 12. The tick time can setting by the configuration No.20. |
The interval time for auto report thetemperature.0 means turn off auto reporttemperature.The default value is 12. The tick timecan setting by the configuration No.20. Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the temperature. 0 means turn off auto report temperature. The default value is 12. The tick time can setting by the configuration No.20. |
Setting the BASIC command value toturn on the light. The 0xFF(-1) meansturn on the light. For dimmerequipment 1 to 100 means the lightstrength.0 means turn off the light.Caution: The value is unsigned byte,the range is from 0x00 ~ 0xFF. Size: 1 Byte, Default Value: -127
Setting | Description |
---|---|
-127 - 127 | Setting the BASIC command value to turn on the light. The 0xFF(-1) means turn on the light. For dimmer equipment 1 to 100 means the light strength. 0 means turn off the light. Caution: The value is unsigned byte, the range is from 0x00 ~ 0xFF. |
The interval time for auto report eachtick. Setting this configuration willeffect configuration No.10, No.11,No.12 and No.13.The unit is 1 minute.Caution1: Setting to 0 means turnoff all auto report function.Caution2: The value is unsignedbyte, the range is from 0x00 ~ 0xFF Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
-127 - 127 | The interval time for auto report each tick. Setting this configuration will effect configuration No.10, No.11, No.12 and No.13. The unit is 1 minute. Caution1: Setting to 0 means turn off all auto report function. Caution2: The value is unsigned byte, the range is from 0x00 ~ 0xFF |
The temperature differential to report.0 means turn off this function.The unit is Fahrenheit.Enable this function the device willdetect every minutes.And when the temperature is over 140degree Fahrenheit, it will continuereport.Enable this functionality will causesome issue please see the detail in theTemperature Report section. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 127 | The temperature differential to report. 0 means turn off this function. The unit is Fahrenheit. Enable this function the device will detect every minutes. And when the temperature is over 140 degree Fahrenheit, it will continue report. Enable this functionality will cause some issue please see the detail in the Temperature Report section. |
The illumination differential to report.0 means turn off this function.The unit is percentage.Enable this function the device willdetect every minutes.Enable this functionality will causesome issue please see the detail in theIllumination Report section. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 99 | The illumination differential to report. 0 means turn off this function. The unit is percentage. Enable this function the device will detect every minutes. Enable this functionality will cause some issue please see the detail in the Illumination Report section. |
Setting the illumination threshold toturn on the light. When the eventtriggered and the environmentillumination lower then the threshold,the device will turn on the light.0 means turn off illumination detectedfunction. And never turn on the light.1 means darkest.99 means brightest.100 means turn off illuminationdetected function. And always turn onthe light.Notice: In none test mode, only thevalue in 1 to 99 will enable theillumination detected function andupdate the illumination value. Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
0 - 100 | Setting the illumination threshold to turn on the light. When the event triggered and the environment illumination lower then the threshold, the device will turn on the light. 0 means turn off illumination detected function. And never turn on the light. 1 means darkest. 99 means brightest. 100 means turn off illumination detected function. And always turn on the light. Notice: In none test mode, only the value in 1 to 99 will enable the illumination detected function and update the illumination value. |
Operation mode. Using bit to control.Caution: The value is unsigned byte,the range is from 0x00 ~ 0xFF.Bit1: 1 means test mode,0 means normal mode.Notice:This bit only effect by the DIP Switchsetting to customer mode, otherwiseit decides by DIP Switch setting toTest or Normal Mode.Bit2: Disable the door/windowfunction. (1:Disable, 0:Enable)Bit3: Setting the temperature scale.0: Fahrenheit, 1:CelsiusBit4: Disable the illumination reportafter event triggered. (1:Disable,0:Enable)Bit5: Disable the temperature reportafter event triggered. (1:Disable,0:Enable) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Bit1: 1 means test mode, 0 means normal mode. Notice: This bit only effect by the DIP Switch setting to customer mode, otherwise it decides by DIP Switch setting to Test or Normal Mode. |
2 | Disable the door/window function. (1:Disable, 0:Enable) |
3 | Bit3: Setting the temperature scale. 0: Fahrenheit, 1:Celsius |
4 | Bit4: Disable the illumination report after event triggered. (1:Disable, 0:Enable) |
5 | Bit5: Disable the temperature report after event triggered. (1:Disable, 0:Enable) |
Multisensor function switch. Using bitto control.Caution: The value is unsigned byte,the range is from 0x00 ~ 0xFF.Bit0: Disable magnetic integrateillumination to turn ON the lightingnodes in the association group 2.(1:Disable, 0:Enable)Bit4: Disable delay 5 seconds to turnoff the light, when door/windowBit5: Disable auto turn off the light,after door/window opened to turn onthe light. (1:Disable, 0:Enable)Notice: If bit2 is zero, this setting isuseless.Notice: If the configuration No.9 iszero, this setting is useless. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
0 | Bit0: Disable magnetic integrate illumination to turn ON the lighting nodes in the association group 2. (1:Disable, 0:Enable) |
4 | Bit4: Disable delay 5 seconds to turn off the light, when door/window |
5 | Bit5: Disable auto turn off the light, after door/window opened to turn on the light. (1:Disable, 0:Enable) Notice: If bit2 is zero, this setting is useless. Notice: If the configuration No.9 is zero, this setting is useless. |
Customer function switch, using bitcontrol.Caution: The value is unsigned byte,the range is from 0x00 ~ 0xFFBit3: Disable send out BASIC OFFafter door closed. (1:Disable,0:Enable)Bit4: Notification Type,0: Using Notification Report.1: Using Sensor Binary ReportBit5: Disable Multi CC in auto report.(1:Disable, 0:Enable)Bit6: Disable to report battery statewhen the device triggered. (1:Disable,0:Enable) Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
3 | Bit3: Disable send out BASIC OFF after door closed. (1:Disable, 0:Enable) |
4 | Bit4: Notification Type, 0: Using Notification Report. 1: Using Sensor Binary Report |
5 | Bit5: Disable Multi CC in auto report. (1:Disable, 0:Enable) |
6 | Bit6: Disable to report battery state when the device triggered. (1:Disable, 0:Enable) |
After turn on the lighting, setting thedelay time to turn off the lightingwhen the PIR motion is not detected.8 seconds per tick, default tick is 4 (32seconds).0 means never send turn off lightcommand Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
0 - 127 | After turn on the lighting, setting the delay time to turn off the lighting when the PIR motion is not detected. 8 seconds per tick, default tick is 4 (32 seconds). 0 means never send turn off light command |
Hardware Platform | SD3502 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.29:01.20 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-18036036 |
Z-Wave Product Id | 0x013C.0x0002.0x000E |
Sensors | Air TemperatureLuminance |
Supported Notification Types | Home Security |
Frequency | Russia - 868.4MHz, 869.85MHz |
Maximum transmission power | 5 mW |