Quickstart

This is a secure Door Lock - Keypad for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Set the controller in inclusion mode.2. Press the [*] button.3. Press the Master Pin [1234] button after pressing the [#] button.4. press the [88] button after pressing the [*] button.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The GKT-1000A Z-Wave is a secure electronic door look that supports the Z-Wave Plus standard, which is compatible with earlier version of Z-Wave.A security enabled Z-Wave Controller must be use. The GKT-1000A supports the standard security S0 and the new security standard S2.

Reset to factory default * Use this procedure only in the event that the network primary controller is missingor otherwise inoperable.1. Press the [*] button.2. Press the Master Pin [1234] button after pressing the [#] button.3. press the [00] button after pressing the [*] button.
Inclusion 1. Set the controller in inclusion mode.2. Press the [*] button.3. Press the Master Pin [1234] button after pressing the [#] button.4. press the [88] button after pressing the [*] button.
Exclusion 1. Set the controller in exclusion mode.2. Press the [*] button.3. Press the Master Pin [1234] button after pressing the [#] button.4. press the [99] button after pressing the [*] button.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Doorlock Op

Configuration Parameters

Parameter 1: Auto Relock

1=Auto, 2=Manual
Size: 1 Byte, Default Value: 1

Setting Description
1 - 2 1=Auto, 2=Manual

Parameter 2: Relock Time

Relock Time 1~60 sec.
Size: 1 Byte, Default Value: 7

Setting Description
1 - 60 1~60 sec.

Parameter 3: Sound

1=Mute, 2=Normal, 3=Max
Size: 1 Byte, Default Value: 2

Setting Description
1 - 3 1=Mute, 2=Normal, 3=Max

Parameter 4: Sencer Type

1=NO, 2=NC
Size: 1 Byte, Default Value: 1

Setting Description
1 - 2 1=NO, 2=NC

Parameter 5: Alarm

1=Enable, 2=Disable
Size: 1 Byte, Default Value: 2

Setting Description
1 - 2 1=Enable, 2=Disable

Technical Data

Hardware Platform ZM5101
Device Type Door Lock - Keypad
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.01:01.01
Z-Wave Version 6.71.01
Certification ID ZC10-18026032
Z-Wave Product Id 0x037B.0x0001.0x0001
Supported Notification Types Access ControlEmergency AlarmHome Security
Communications Connections Bluetooth
Frequency XXfrequency
Maximum transmission power XXantenna
South KoreaDoor Lock - Keypad