This is a
Triple click the Z-button quickly.
B.One Motion Sensor can be included and operated in any Z-Wave network with other Z-Wave certified devices. The features list:1)Z-Wave Plus certified for wide compatibility (500 serials product).2)Supports security 0 and security 2 protected mode with AES-128 encryption.3)Motion sensor.4)Tamper alarm by shock sensor.5)The battery life is up to 1 year.6)Low battery alarm.7)Support firmware OTA.
Reset to factory default | 1)Power on the device,2) Press and hold the Z button for more than 20 seconds,3) If holding time more than 20seconds, the LED indicator will keep on for 2 seconds, which means resetting is complete.4) The reset feature works only when the device has been included into a Z-Wave network.Use this procedure only in the event that the network primary controller is missing or otherwise inoperable. |
Inclusion | Triple click the Z-button quickly. |
Exclusion | Triple click the Z-button quickly. |
NIF | XXXNIF |
Wakeup | Press and hold the Z button for more than 5 seconds and release. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline:1. Notification Report.Sensor will send Notification Report to the associated nodes when Motion Sensor is removed or/and PIR is triggered.2. Battery Report.Motion Sensor will send Battery Report when the battery level is low and the battery reports value is 0xFF.3. Device Reset Locally Notification. |
2 | 5 | 1. Basic Set.Motion Sensor will send Basic Set to associated nodes when the PIR is triggered. |
As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:
Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.
If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.
To become primary a contoller have to be resetted and then include a device.
1) Open the cover.2) Place the device within the direct range of your Z-Wave controller.3) Set the main controller in add mode (see the controllers manual).4) Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast. 5) Wait for the adding process to end.6) Successful adding will be confirmed by the Z-Wave controllers message.
The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.
Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.
1) Open the cover.2) Place the device within the direct range of your Z-Wave controller.3) Set the main controller remove mode (see the controllers manual).4) Triple click the Z-button quickly, the LED indicator should blink fast.5) Wait for the removing process to end.6) Successful adding will be confirmed by the Z-Wave controllers message.
The higher the value, the more sensitive the PIR sensor. Size: 1 Byte, Default Value: 8
Setting | Description |
---|---|
1 - 8 | The higher the value, the more sensitive the PIR sensor. |
Motion sensor can send BASIC SET command to nodes associated with group 2 when motion is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Motion Sensor can reverse its value of BASIC SET when motion is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send BASIC SET VALUE = 255 to nodes associated with group 2 when motion alarm is triggered.Send BASIC SET VALUE = 0 to nodes associated with group 2 when motion alarm is canceled. |
1 | Send BASIC SET VALUE = 0 to nodes associated with group 2 when motion alarm is triggered.Send BASIC SET VALUE = 255 to nodes associated with group 2 when motion alarm is canceled. |
Motion alarm will be cancelled in the main controller after 3 seconds, the alarm cancellation can be delay by this parameter. Any motion detected during the cancellation delay time countdown will result in the countdown being restarted. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Reports are not sent |
1 - 65535 | the change in luminance level resulting in luminance report being sent to the main controller. |
Define a battery level as the low battery. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
10 - 50 | The low level from 10% to 50% |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18026021 |
Z-Wave Product Id | 0x0311.0x0002.0x0202 |
Supported Notification Types | Home Security |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Sensors | Air Temperature |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |