This is a
1. Turn the connected appliance ON/OFF by tapping the switch. Tapping and releasing the upper part of the rocker turns the appliance ON. Tapping and releasing the lower part of the rocker turns the appliance OFF.2. Add(Include) the module to/from your Z-Wave network with your primary controller. Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done. 3. Normally, the sequence is as follows: when the inclusion process is prompted by your primary controller, single click and release the rocker switch to ON or OFF position.The controller should show that the action was successful.If the controller shows it was a fail, repeat the procedure.
HS-WS200+ In Wall On/Off Switch- Works with incandescent, florescent (CFL), or most LED lighting and appliances- ON/OFF status and location LED indicator- Includes Z-Wave controllable RGB LED indicator- Fits into standard single or multiple gang junction box- Keypad can be replaced manually to match color with other wall switches - Over-The-Air firmware upgrade available with compatible gateway, Z-Wave static controller, or PC and software.- Internal resettable fuse to protect from surge current- Manual reset capability- Support Central Scene
Reset to factory default | Please use this procedure only in the event that the network primary controller is lost or otherwise inoperable.All Configuration Parameters can all be restored to their factorydefault settings by using your primary controller to delete/resetthe device. To manually reset, tap the ON button twice quickly and then tap the OFF button twice quickly.Repeat the procedure to restore the settings to the factory default. |
Inclusion | 1. Turn the connected appliance ON/OFF by tapping the switch. Tapping and releasing the upper part of the rocker turns the appliance ON. Tapping and releasing the lower part of the rocker turns the appliance OFF.2. Add(Include) the module to/from your Z-Wave network with your primary controller. Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done. 3. Normally, the sequence is as follows: when the inclusion process is prompted by your primary controller, single click and release the rocker switch to ON or OFF position.The controller should show that the action was successful.If the controller shows it was a fail, repeat the procedure. |
Exclusion | 1. Turn the connected appliance ON/OFF by tapping the switch. Tapping and releasing the upper part of the rocker turns the appliance ON. Tapping and releasing the lower part of the rocker turns the appliance OFF.2. Delete(Exclude) the module to/from your Z-Wave network with your primary controller. Please refer to the instructions manual of your gateway or remote controller for details and procedures on how these actions can be done. Normally, the sequence is as follows: when the exclusion process is prompted by your primary controller, single click and release the rocker switch.The controller should show that the action was successful. If the controller shows it was a fail, repeat the procedure. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
This parameter sets the display mode of the LED indicator. In normal mode, the LED reflects the status of the attached load. In Status mode, it can reflect the status of anything the user sets it to. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Normal mode |
1 | Status mode |
This parameter sets the normal mode color of the LED indicator in the switch Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | White |
1 | Red |
2 | Green |
3 | Blue |
4 | Magenta |
5 | Yellow |
6 | Cyan |
This parameter sets to color of the LED indicator in status mode Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Off |
1 | Red |
2 | Green |
3 | Blue |
4 | Magenta |
5 | Yellow |
6 | Cyan |
7 | White |
the LED indicator will be ON when the connected appliance is ON, and vice versa. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | the LED indicator willbeOFF when the connected appliance is ON, and the LED indicator will beON when the connected appliance is OFF |
1 | the LED indicator will beOFF when the connected appliance is OFF, and the LED indicator will beON when the connected appliance is ON |
2 | the LED indicator will be always Off regardless of the load status |
This parameter sets the blink frequency of the LED indicator in status mode. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | No Blink |
1 - 255 | 1=100 ms |
the orientation of the ON/OFF on the rocker switch can be inverted by changing the following configuration with a controller(if supported) Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | the connected light will turn ON by pressing the top side of the rocker switch and turn OFF by pressing the bottom side. |
1 | the connected light will turn OFF by pressing the top side of the rocker switch and turn ON by pressing the bottom side. |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 255 FW: 5.06 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18026018 |
Z-Wave Product Id | 0x000C.0x4447.0x3035 |
Electric Load Type | ELV (Electronic)FluorescentIncandescentInductive (e.g. Motor)LEDMLV (Magnetic) |
Firmware Updatable | Updatable by Consumer by RF |
Z-Wave Scene Type | Scene & Central Scene |
Color | White |
Neutral Wire Required | ok |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |