Quickstart

This is a Wall Controller for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
When the pushbutton is released after a press of (2sec



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Master Roller Blind IO is ready to operate with Z-Wave controllers and configured to be managed by Simon100 IO APP using the HUB plug IO for getting a better user experience. Sending the Blind controller by other window covering devices Up/Down/Stop.

Reset to factory default When the pushbutton is released after a press of (30sec
Inclusion When the pushbutton is released after a press of (2sec
Exclusion When the pushbutton is released after a press of (2sec
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 3 Z-Wave Plus Lifeline
2 20 ctrl.This group is used to add the devices to be controlled by Master Roller blind. Device sends Basic Sets, Multilevel Start or Stop level change when controlling sunblinds, and Manufacturer specific Gets, Configuration Gets and Sets when manual association is being performed over Simon devices.

Configuration Parameters

Parameter 1: Association LED

Activates the Central LED. Configuration Used by Masters iO in order to identify the devices associated to their Group2 during manual association process.
Size: 1 Byte, Default Value: 0

Setting Description
0 Turns Central LED OFF
1 - 255 Turns Central LED ON

Parameter 12: Behavior of LED in Repose

Sets the Left and Right LEDs to 20% in order to find the device and the touch areas at night.
Size: 1 Byte, Default Value: 0

Setting Description
0 Left and Right LEDs OFF
1 - 255 Left and Right LEDs ON at 20percent

Parameter 13: Lock Input

Locks the local control of associated devices and controller. This configuration does not modifies the control via Z-Wave, where if a Set is received it will retransmitted to all group 2 associated nodes
Size: 1 Byte, Default Value: 0

Setting Description
0 Local action enabled
1 - 255 Local action locked

Parameter 15: Reset Default

Write only parameter used to restore configurations or perform a completely restore default.
Size: 1 Byte, Default Value: 0

Setting Description
39015 Factory reset
17170 Configuration values are restored

Parameter 18: Lock Manual Assocaition

Enables or disables the manual association process.
Size: 1 Byte, Default Value: 0

Setting Description
0 Hold press of 10sec to 30sec starts manual association of devices to group 2
1 - 255 Hold press of 10sec to 30sec sends a Node Info

Parameter 19: Press Action

Defines the function performed by the device when keypad is pressed
Size: 1 Byte, Default Value: 7

Setting Description
0 short press switches between the last power on and off (depending on the status of the associated control) by sending a Basic Set to 0x00 or 0xFF to the associated nodes. The touch area does not work
1 Short press activates those associated by sending Basic Set to 0xFF
2 Short press deactivates those associated by sending Basic Set to 0x00
3 Short Press UP always activates those associated with the last power on by sending a Basic Set 0xFF. Short Press DOWN always deactivates those associated by sending a Basic Set to 0x00.
4 Short Press always turn on the associated nodes by sending a Basic Set to 0xFF. Press from 2sec to 10sec always turns off the associated nodes by sending a Basic Set to 0x00
6 Short pressi on UP Area, if controlled device/s already have the value set on Config Param 26, Basic Set 0x00 is sent and UP and DOWN LEDs are turned off; Otherwise Basic Set with value (Param 26) is sent and UP LED light up for 5 sec. After short pressing on DOWN Area, if controlled device/s already have the value set on Config Param 25, Basic Set 0x00 is sent and UP
7 the key works as described on keypad use and feedbaks

Parameter 20: Identify

Write only value that performs a fast blink on Central LED during 5 seconds in order to identify the device when it is installed in a multiple frame
Size: 1 Byte, Default Value: 0

Setting Description
1 - 255 Central LED performs a fast blink

Parameter 21: Device State

Configuration used to know the device state and last dimming or sunblind position.
Size: 2 Byte, Default Value: 0

Setting Description
0 - 99 Load is OFF or sunblind is stopped with diming value or position x
256 - 355 Load is ON or sunblind is going DOWN with diming value or position x
512 - 611 Load is ON or sunblind is going UP with diming value or position x

Parameter 25: Left Side Value

Value used as DOWN side value when Parameter 20 value is 6Value is SET in hexadecimal format.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 99 Value used as DOWN side value when Parameter 20 value is 6 in order to set the loat to the value
255 Value used as UP side value when Parameter 20 value is 6 in order to Activate Load

Parameter 26: Right Side Value

Value used as UP side value when Parameter 20 value is 6Value is SET in hexadecimal format.
Size: 1 Byte, Default Value: 255

Setting Description
0 - 99 Value used as UP side value when Parameter 20 value is 6 in order to Set Load to this value
255 Value used as UP side value when Parameter 20 value is 6 in order to Activate Load

Parameter 27: Lock Hold Press

Locks the major part of Hold press effects in order to avoid undesired Z-Wave changes, associations or restores Default. 0xFF Hold Press from 2sec to 10 sec does not performs a Node info. Hold Press of 10 to 30 does not performs a manual association process. Hold press of 30sec restores configuration except Lock Hold Press, and sends a Node info in order to add or remove from Z-Wave Network.
Size: 1 Byte, Default Value: 0

Setting Description
0 Hold press is available
1 - 255 Hold Press is Locked

Parameter 28: Consult on Touch

This configuration has only effects when there is only 1 associated node in group 2.Is used to set if Master has to be always informed about the controlled device state or it is consulted when user touchs the keypad.
Size: 1 Byte, Default Value: 255

Setting Description
0 Device must receive reports about controlled device state.
1 - 255 Device consults the device state once keypad detects touch

Parameter 29: Send Central Scene

Disables the sending of Central Scene Notifications to avoid perform 2 actions at same time (Central Scene action and Group 2 action).
Size: 1 Byte, Default Value: 255

Setting Description
0 Device does not sends Central Scene Notifications
1 - 255 Device sends Central Scene Notifications is no devices are added to group 2

Technical Data

Hardware Platform ZM5202
Device Type Wall Controller
Network Operation Always On Slave
Firmware Version HW: 1 FW: 4.24:76.51
Z-Wave Version 6.51.07
Certification ID ZC10-18026014
Z-Wave Product Id 0x0267.0x0005.0x0000
Firmware Updatable Updatable by Professional/Technician
Neutral Wire Required ok
Z-Wave Scene Type Central Scene
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Wall Controller