This is a
Inclusion After power up the device (not included), the ex-/inclusion button lights permanently in color red. To start the inclusion mode the ex-/inclusion button on Room Display must be pressed for at least 1.5 seconds.If the time of 1.5 seconds is reached the segment starts to blink red.During inclusion ex-/inclusion button lit white. Segment3 switched of and device sounds dingdong if device is completely entered the network.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
The room display is a four-way button with integrated RGB LED lighting and MP3 player for switching (e.g. socket module ...) and displaying states of Z-Wave network components or system functions. When a key is pressed, a notification message frame is sent with the information - key number, number of actuations. The LED RGB illumination of the buttons can be controlled via the Z-Wave controller. Currently, in the standard version of the room display three sounds are stored in the MP3 player and can be activated via the controller. In addition, the room display includes a temperature and humidity sensor. The measured values can be queried directly or / and transmitted cyclically (configurable from 1 minute to 254 minutes). The function of the individual keys is indicated by an exchangeable symbol (foil). The product is available as wall or table version. The room display is powered by a fixed power supply. It is a wide-range power supply (primary 100V-240V AC / secondary 12V / 1A DC). For wall mounting, it can be installed via a separate flush-mounted power supply unit. When installing via the flush-mounted power supply, the installation must be carried out by a specialist.The room display can be used for various use cases. For example, an alarm function (window / door monitoring) can be realized via the room display. The buttons on the room display can be used to activate and deactivate the alarm function. In case of a triggered alarm, the room display can show the alarm with a visual and acoustic signal. It should be noted that the room display does not have its own intelligence, so the functionality must be realized via the Z-Wave controller. Other use cases are e.g. activate and deactivate scenarios, switch on and off a power module, reminder of appointments, medication,... .
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Factory default ResetThe Room Display can be removed from the network. This can only be done within the first minute after plugging in the power plug. The function cannot be activated later.1. For Device Reset unplug the device for 10 seconds. 2. Device plug in3. Press button1 1x, button2 2x, button3 3x and button4 4x => segment4 is flashing in color magenta.4. Press button4 1xThe device restarts now, sets all settings (brightness, volume, ) to default and flashing all 4 segments for 1 second with color white.Please use this procedure only when the network primary controller is missing or otherwise inoperable.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Support one association group with one node.Support grouping identifier: 1 (lifeline)All triggering reports will be sent to the associated node:COMMAND_CLASS_DEVICE_RESET_LOCALLYDEVICE_RESET_LOCALLY_NOTIFICATIONCOMMAND_CLASS_CENTRAL_SCENECENTRAL_SCENE_NOTIFICATIONCOMMAND_CLASS_SENSOR_MULTILEVEL_V9SENSOR_MULTILEVEL_REPORT_V9 |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Standard volume setting Size: 1 Byte, Default Value: 25
Setting | Description |
---|---|
0 - 30 | volume sound |
Definition of the color value (RGB) - Color table row 5Command class color switch Size: 4 Byte, Default Value: 38400
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 5 |
Definition of the color value (RGB) - Color table row 6Command class color switch Size: 4 Byte, Default Value: 25625
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 6 |
Definition of the color value (RGB) - Color table row 7Command class color switch Size: 4 Byte, Default Value: 255
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 7 |
Definition of the color value (RGB) - Color table row 9Command class color switch Size: 4 Byte, Default Value: 8192255
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 9 |
Definition of the color value (RGB) - Color table row 10Command class color switch Size: 4 Byte, Default Value: 16711805
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 10 |
Definition of the color value (RGB) - Color table row 11Command class color switch Size: 4 Byte, Default Value: 16743830
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 11 |
Definition of the color value (RGB) - Color table row 12Command class color switch Size: 4 Byte, Default Value: 16777215
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 12 |
Definition of the color value (RGB) - Color table row 13Command class color switch Size: 4 Byte, Default Value: 16777215
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 13 |
Definition of the color value (RGB) - Color table row 14Command class color switch Size: 4 Byte, Default Value: 16777215
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 8 |
0 - 16777215 | RGB Value Color table row 14 |
Volume settingfor Alarm sound Size: 1 Byte, Default Value: 27
Setting | Description |
---|---|
0 - 30 | Alarm Volume |
Definition of the color value (RGB) - Color table row 15Command class color switch Size: 4 Byte, Default Value: 16777215
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 15 |
Definition of the color value (RGB) - Color table row 16Command class color switch Size: 4 Byte, Default Value: 16777215
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 16 |
Definition of the color value (RGB) - Color table row 17Command class color switch Size: 4 Byte, Default Value: 16777215
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 17 |
Definition of the color value (RGB) - Color table row 18Command class color switch Size: 4 Byte, Default Value: 16777215
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 18 |
Definition of the color value (RGB) - Color table row 19Command class color switch Size: 4 Byte, Default Value: 16777215
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 19 |
Send cycle for measured value [min] for Temperature ans Humidity Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 127 | Send cycle for measured value [min] for Temperature ans Humidity |
Define alarm sound number.This sound is played endless with VOLUME_ALARM. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 3 | Define alarm sound number |
Correction value temperature measurement (slope)Slope = Value / 10000 Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
100 - 32767 | Slope = Value/10000 |
Correction value Temperature measurement (Offset)Temperature Offset [0.1C] Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
-128 - 128 | Temperature Offset [0.1C] |
Definition of the color value (RGB) - Color table row 0Command class color switch Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 0 |
Definition of the color value (RGB) - Color table row 1Command class color switch Size: 4 Byte, Default Value: 16711680
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 1 |
Definition of the color value (RGB) - Color table row 2Command class color switch Size: 4 Byte, Default Value: 16730880
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 2 |
Definition of the color value (RGB) - Color table row 3Command class color switch Size: 4 Byte, Default Value: 16762880
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 3 |
Definition of the color value (RGB) - Color table row 4Command class color switch Size: 4 Byte, Default Value: 3302400
Setting | Description |
---|---|
0 - 16777215 | RGB Value Color table row 4 |
Hardware Platform | ZM5202 |
Device Type | Wall Controller |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.01:01.01 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18026003 |
Z-Wave Product Id | 0x0348.0x0002.0x0001 |
Firmware Updatable | Updatable by Manufacturer |
Color | White |
Switch Type | Push Button Illuminated |
Sensors | Air TemperatureHumidity |
Z-Wave Scene Type | Central Scene |
Communications Protocol | Z-Wave Serial API |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |