Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Press & hold inclusion/Exclusion button during 1 seconds when Open Sensor is exclusion status Press for 1seconds, LED is turn on Open sensor will try inclusion for 15 seconds when button is released.If inclusion is successful, LED will blink 3 times with 100ms interval



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Reset to factory default Press & hold inclusion/Exclusion button during 5 seconds. LED turn on and LED turn off after 5sec Release Inclusion/Exclusion Factory reset will be done in 5 seconds and blink 5 times with 100ms intervalPlease use factory reset only when the network primary controller is missing or otherwise inoperable
Inclusion Press & hold inclusion/Exclusion button during 1 seconds when Open Sensor is exclusion status Press for 1seconds, LED is turn on Open sensor will try inclusion for 15 seconds when button is released.If inclusion is successful, LED will blink 3 times with 100ms interval
Exclusion Press & hold inclusion/Exclusion button during 1 seconds when Open Sensor is exclusion status Press for 1seconds, LED is turn on Open sensor will try exclusion when button is released. If exclusion is successful, LED will blink 3 times with 100ms interval
NIF XXXNIF
Wakeup Wake up Notification is transmitted every 30 minutes by defaultWake up Notification can be changed in controller
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Lifeline between controller and KMS-Z10 Supported command classes Battery report, Notification report, and Device Reset Locally notification Sensor can max associate 1 nodes in each group Sensor supports one association groupings.

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 3 FW: 1.01
Z-Wave Version 6.71.01
Certification ID ZC10-18015981
Z-Wave Product Id 0x034C.0x0003.0x0001
Color White
Supported Notification Types Home Security
Sensors Motion/No Motion (Binary)
Frequency XXfrequency
Maximum transmission power XXantenna
South KoreaNotification Sensor