Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
1 Power up the device.2 Set Z-Wave Controller into inclusion mode3 Press the button 3 times within 1.5s to enter inclusion mode.4 The device will be recognized and automatically included into Z-WaveNetwork.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Reset to factory default Note : please use the reset procedure only when the primary controller is missing or inoperable.Operation: 1 Power up the device.2 Press and hold the button for 10s until led lights is on, then release thebutton.
Inclusion 1 Power up the device.2 Set Z-Wave Controller into inclusion mode3 Press the button 3 times within 1.5s to enter inclusion mode.4 The device will be recognized and automatically included into Z-WaveNetwork.
Exclusion 1 Power up the device.2 Set Z-Wave Controller into exclusion mode3 Press the button 3 times within 1.5s to enter exclusion mode
NIF XXXNIF
Wakeup Press the button briefly, Led will blink once.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Z-Wave Plus Lifeline, all nodes which associated in this group will receive the messages sent by device through lifeline.
2 5 It is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects a movement event or a tampering event.
3 5 It is is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects an ambient temperature alarm (Decided by configuration parameter 16, 17).
4 5 It isis controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects an ambient humidity alarm (Decided by configuration parameter 14, 15).

Configuration Parameters

Parameter 1: Motion Sensitivity

This parameter is configured the sensitivity that motion detect.
Size: 1 Byte, Default Value: 1

Setting Description
1 - 100 This value is larger, the sensitivity is lower, and the distance for motion detecting is closer.

Parameter 10: Basic Set Level

This parameter is configured the value that BASIC_SET for nodes that associated in Group 2, 3, 4.100BASIC_SET = 0xFF (ON).0BASIC_SET = 0x00 (OFF).
Size: 1 Byte, Default Value: 100

Setting Description
0 - 99 BASIC_SET = 0x00 ~ 0x63
100 BASIC_SET = 0xFF

Parameter 11: Sensor Measuring Interval

This parameter is configured the time interval for temperature and humidity sensor measure the ambient temperature and humidity value. This value is larger, the battery life is longer. And the value changed is not obvious.
Size: 2 Byte, Default Value: 180

Setting Description
30 - 3600 set the time interval for temperature and humidity sensor measure the ambient temperature and humidity value.

Parameter 12: Temperature Differential Report

This parameter is configured the value that differential between current measured and previous report value. If the differential value larger than the settings, device will report this measured temperature value to nodes associated in lifeline.
Size: 1 Byte, Default Value: 10

Setting Description
1 - 127 Differential Value =Value x 0.1

Parameter 13: Humidity Differential Report

This parameter is configured the value that differential between current measured and previous report value. If the differential value larger than the settings, device will report this measured relative humidity value to nodes associated in lifeline.
Size: 1 Byte, Default Value: 50

Setting Description
1 - 127 Differential Value = Value x 0.1% RH

Parameter 14: Low Level Humidity Threshold

This parameter is configured the threshold value that low level for humidity.When the current ambient humidity value is lower than this configuration value, this will trigger a BASIC_SET = [Value] (The value is decided by Configuration Parameter 10) to control the devices in group 4.Otherwise, The BASIC_SET = 0x00 will be sent to devices in group 4 if these devices have been set to ON.
Size: 2 Byte, Default Value: 300

Setting Description
10 - 999 Low Level Value = Value x 0.1% RH

Parameter 15: High Level Humidity Threshold

This parameter is configured the threshold value that high level for humidity.When the current ambient humidity value is larger than this configuration value, this will trigger a BASIC_SET = [Value] (The value is decided by Configuration Parameter 10) to control the devices in group 4.Otherwise, The BASIC_SET = 0x00 will be sent to devices in group 4 if these devices have been set to ON.
Size: 2 Byte, Default Value: 900

Setting Description
10 - 999 High Level Value =Value x 0.1% RH

Parameter 16: Low Level Temperature Threshold

This parameter is configured the threshold value that low level for temperature.When the current ambient temperature value is lower than this configuration value, this will trigger a BASIC_SET = [Value] (The value is decided by Configuration Parameter 10) to control the devices in group 3.Otherwise, The BASIC_SET = 0x00 will be sent to devices in group 3 if these devices have been set to ON.
Size: 2 Byte, Default Value: 150

Setting Description
0 - 500 Low Level Value = Value x 0.1

Parameter 17: High Level Temperature Threshold

This parameter is configured the threshold value that high level for temperature.When the current ambient temperature value is larger than this configuration value, this will trigger a BASIC_SET = [Value] (The value is decided by Configuration Parameter 10) to control the devices in group 3.Otherwise, The BASIC_SET = 0x00 will be sent to devices in group 3 if these devices have been set to ON.
Size: 2 Byte, Default Value: 300

Setting Description
0 - 500 High Level Value =Value x 0.1

Parameter 2: Motion Window Time

This parameter is configured the specified time window (4s..16s) in which the amount of pulses will trigger a motion event.
Size: 1 Byte, Default Value: 2

Setting Description
0 - 3 Window Time = [Value] * 4s + 4s

Parameter 3: Pulse Count

This parameter is configured amount of pulses during the specified time window which trigger a motion event.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 3 Amount of pluses = [Value] + 1.

Parameter 4: Motion Blind Time

This parameter is configured the no motion detected time after a motion event detects. The device will wait for setting times to ready to next detect.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 15 Blink Time = ([Value] + 1) * 0.5s.

Parameter 5: Motion Enable

This parameter is configured the motion detected if enable or not. If 1, Motion detected function is enable. Otherwise is disabled.
Size: 1 Byte, Default Value: 1

Setting Description
0 Motion detected function is disabled
1 Motion detected function is enable

Parameter 6: Motion Clear Time

This parameter is configured the time to clear motion event after a motion event detected. Time to motion clear, the device will send a clear event report to controller. Unit: Second.
Size: 2 Byte, Default Value: 30

Setting Description
10 - 3600 set the time to clear motion event after a motion event detected

Parameter 7: Motion Event Re-trigger Enable

This configuration sets Motion Event Re-trigger is enabled or disabled.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disabled. The motion event will be sent to controller only when the last motion event is cleared.
1 Enabled. The time interval for motion event detecting is defined by configuration No. 4.

Parameter 8: Led Indicate Enable

This parameter is configured the Led light on disable or enable.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable led blink. This configuration is not affecting inclusion, exclusion and reset.
1 Enable Led blink when device detects a motion event.

Parameter 9: Binary Sensor Report Enable

This configuration sets binary sensor report is enabled or disabled.
Size: 1 Byte, Default Value: 0

Setting Description
0 Disable sensor binary report when device detects a motion event.
1 Enable sensor binary report when device detects a motion event.

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 17 FW: 1.80
Z-Wave Version 6.71.01
Certification ID ZC10-18015965
Z-Wave Product Id 0x033A.0x0003.0x0100
Supported Notification Types Home Security
Sensors Air TemperatureHumidityMotion/No Motion (Binary)
Color White
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor