This is a
1 Power up the device.2 Set Z-Wave Controller into inclusion mode3 Press the button 3 times within 1.5s to enter inclusion mode.4 The device will be recognized and automatically included into Z-WaveNetwork.
This product can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.
Reset to factory default | Note : please use the reset procedure only when the primary controller is missing or inoperable.Operation: 1 Power up the device.2 Press and hold the button for 10s until led lights is on, then release thebutton. |
Inclusion | 1 Power up the device.2 Set Z-Wave Controller into inclusion mode3 Press the button 3 times within 1.5s to enter inclusion mode.4 The device will be recognized and automatically included into Z-WaveNetwork. |
Exclusion | 1 Power up the device.2 Set Z-Wave Controller into exclusion mode3 Press the button 3 times within 1.5s to enter exclusion mode |
NIF | XXXNIF |
Wakeup | Press the button briefly, Led will blink once. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline, all nodes which associated in this group will receive the messages sent by device through lifeline. |
2 | 5 | It is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects a movement event or a tampering event. |
3 | 5 | It is is controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects an ambient temperature alarm (Decided by configuration parameter 16, 17). |
4 | 5 | It isis controlling group, all nodes associated in this group will be controlled through BASIC_SET command by the device when device detects an ambient humidity alarm (Decided by configuration parameter 14, 15). |
This parameter is configured the sensitivity that motion detect. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 100 | This value is larger, the sensitivity is lower, and the distance for motion detecting is closer. |
This parameter is configured the value that BASIC_SET for nodes that associated in Group 2, 3, 4.100BASIC_SET = 0xFF (ON).0BASIC_SET = 0x00 (OFF). Size: 1 Byte, Default Value: 100
Setting | Description |
---|---|
0 - 99 | BASIC_SET = 0x00 ~ 0x63 |
100 | BASIC_SET = 0xFF |
This parameter is configured the time interval for temperature and humidity sensor measure the ambient temperature and humidity value. This value is larger, the battery life is longer. And the value changed is not obvious. Size: 2 Byte, Default Value: 180
Setting | Description |
---|---|
30 - 3600 | set the time interval for temperature and humidity sensor measure the ambient temperature and humidity value. |
This parameter is configured the value that differential between current measured and previous report value. If the differential value larger than the settings, device will report this measured temperature value to nodes associated in lifeline. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 127 | Differential Value =Value x 0.1 |
This parameter is configured the value that differential between current measured and previous report value. If the differential value larger than the settings, device will report this measured relative humidity value to nodes associated in lifeline. Size: 1 Byte, Default Value: 50
Setting | Description |
---|---|
1 - 127 | Differential Value = Value x 0.1% RH |
This parameter is configured the threshold value that low level for humidity.When the current ambient humidity value is lower than this configuration value, this will trigger a BASIC_SET = [Value] (The value is decided by Configuration Parameter 10) to control the devices in group 4.Otherwise, The BASIC_SET = 0x00 will be sent to devices in group 4 if these devices have been set to ON. Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
10 - 999 | Low Level Value = Value x 0.1% RH |
This parameter is configured the threshold value that high level for humidity.When the current ambient humidity value is larger than this configuration value, this will trigger a BASIC_SET = [Value] (The value is decided by Configuration Parameter 10) to control the devices in group 4.Otherwise, The BASIC_SET = 0x00 will be sent to devices in group 4 if these devices have been set to ON. Size: 2 Byte, Default Value: 900
Setting | Description |
---|---|
10 - 999 | High Level Value =Value x 0.1% RH |
This parameter is configured the threshold value that low level for temperature.When the current ambient temperature value is lower than this configuration value, this will trigger a BASIC_SET = [Value] (The value is decided by Configuration Parameter 10) to control the devices in group 3.Otherwise, The BASIC_SET = 0x00 will be sent to devices in group 3 if these devices have been set to ON. Size: 2 Byte, Default Value: 150
Setting | Description |
---|---|
0 - 500 | Low Level Value = Value x 0.1 |
This parameter is configured the threshold value that high level for temperature.When the current ambient temperature value is larger than this configuration value, this will trigger a BASIC_SET = [Value] (The value is decided by Configuration Parameter 10) to control the devices in group 3.Otherwise, The BASIC_SET = 0x00 will be sent to devices in group 3 if these devices have been set to ON. Size: 2 Byte, Default Value: 300
Setting | Description |
---|---|
0 - 500 | High Level Value =Value x 0.1 |
This parameter is configured the specified time window (4s..16s) in which the amount of pulses will trigger a motion event. Size: 1 Byte, Default Value: 2
Setting | Description |
---|---|
0 - 3 | Window Time = [Value] * 4s + 4s |
This parameter is configured amount of pulses during the specified time window which trigger a motion event. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 3 | Amount of pluses = [Value] + 1. |
This parameter is configured the no motion detected time after a motion event detects. The device will wait for setting times to ready to next detect. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 15 | Blink Time = ([Value] + 1) * 0.5s. |
This parameter is configured the motion detected if enable or not. If 1, Motion detected function is enable. Otherwise is disabled. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Motion detected function is disabled |
1 | Motion detected function is enable |
This parameter is configured the time to clear motion event after a motion event detected. Time to motion clear, the device will send a clear event report to controller. Unit: Second. Size: 2 Byte, Default Value: 30
Setting | Description |
---|---|
10 - 3600 | set the time to clear motion event after a motion event detected |
This configuration sets Motion Event Re-trigger is enabled or disabled. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disabled. The motion event will be sent to controller only when the last motion event is cleared. |
1 | Enabled. The time interval for motion event detecting is defined by configuration No. 4. |
This parameter is configured the Led light on disable or enable. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable led blink. This configuration is not affecting inclusion, exclusion and reset. |
1 | Enable Led blink when device detects a motion event. |
This configuration sets binary sensor report is enabled or disabled. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable sensor binary report when device detects a motion event. |
1 | Enable sensor binary report when device detects a motion event. |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 17 FW: 1.80 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18015965 |
Z-Wave Product Id | 0x033A.0x0003.0x0100 |
Supported Notification Types | Home Security |
Sensors | Air TemperatureHumidityMotion/No Motion (Binary) |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |