This is a
1.Set the Z-Wave network main controller into learning mode.2.Short press the Z-button twice3.The LED keep blink to the end of add inclusion, If the add for inclusion is successful, LED will turn on within 2 seconds and Then will be in power indication mode, Otherwise, The LED will keep slow flash.
Smart Plug can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the products firmware upgrade.If you want your Smart Plug to be a security device that use secure/encrypted message to communicate in a Z-Wave network, then a security enabled Z-Wave controller is needed.
Reset to factory default | Reset Smart Plug to factory Default:1.Make sure that the Smart Plug has been connected to the power supply.2.Press and hold the Z-button for 5 seconds.3.If holding time is more than one second, the LED will blink faster and faster. If holding time is more than 5 seconds, the LED will be solid for 3 seconds to indicate that the resetting is successful. Otherwise, repeat step 2. Use this procedure only in the event that the network primary controller missing or otherwise inoperable. |
Inclusion | 1.Set the Z-Wave network main controller into learning mode.2.Short press the Z-button twice3.The LED keep blink to the end of add inclusion, If the add for inclusion is successful, LED will turn on within 2 seconds and Then will be in power indication mode, Otherwise, The LED will keep slow flash. |
Exclusion | 1.Set the Z-Wave network main controller into removing mode.2.Short press Z-button twice.3.The LED keep blink to the end of remove exclusion, If the remove for exclusion is successful, The LED will keep slow flash, Otherwise, LED will be in power indication mode. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | 1. When the state of Smart Plug (turn on or off the load) is changed:1.Set Configuration parameter 0x03 to 0:Do not send Basic Report2. Set Configuration parameter 0x03 to 1: Send Basic Report3. Set Configuration parameter 0x03 to 2: Send Basic Report only when Load condition is changed not by Z-WAVE Command, such as short pressing.2. Sending Meter Report. |
Smart Plug keep detecting the load power, once the AC current exceeds 16A for more than 5s, smart plug's relay will turn off. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | The function is disabled |
1 | The function is enabled. |
Setting the parameters 101~104 to the default value. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
85 | Setting the parameters 101~104 to the default value. |
The interval time of sending meter report (watt) to associated device (Group Lifeline). Size: 4 Byte, Default Value: 600
Setting | Description |
---|---|
5 - 2678400 | Available settings |
0 | The function is disabled. |
The interval of sending meter report (KWh) to association device (Group Lifeline). Size: 4 Byte, Default Value: 3600
Setting | Description |
---|---|
5 - 2678400 | Available settings |
0 | The function is disabled. |
The interval of sending meter report (voltage) to association device (Group Lifeline). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
5 - 2678400 | Available settings |
0 | The function is disabled |
The interval time of sending meter report (current) to associated device (Group Lifeline). Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
5 - 2678400 | Available settings |
0 | The function is disabled |
When the change value of load power exceeds the setting value, smart plug will send meter report (watt)to associated device (Group Lifeline). Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
1 - 65535 | Available settings |
0 | The function is disabled. |
When the change value of the load power exceeds the setting value, smart plug will send meter report to associated device (Group Lifeline). Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
-128 - 127 | Available setting |
0 | The function is disabled. |
Define how the Plug reacts after the power supply is back on. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Smart Plug memorizes its state after a power failure. |
1 | Connected device will be on after the power supply is reconnected. |
2 | Connected device will be off after the power supply is reconnected. |
Lock/unlock all configuration parameters. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Unlock |
1 | Lock |
Smart Plug can send notifications to associated device (Group Lifeline) when the status of smart plugs load is changed. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | The function is disabled. |
1 | Send Basic report. |
2 | Send Basic report only when Load status is not changed by Z-WAVE Command. |
Configure LED Display mode to prevent light pollution at night. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The LED status follows the load change. |
1 | when operating the load, The LED lights for 5 seconds and then turns off. |
Hardware Platform | ZM5101 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.00 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-18015958 |
Z-Wave Product Id | 0x0300.0x0200.0x000B |
Supported Meter Type | Electric Energy |
Switch Type | Push Button |
Z-Wave Scene Type | Scene |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |