This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1.Set the Z-Wave network main controller into learning mode.2.Short press the Z-button twice3.The LED keep blink to the end of add inclusion, If the add for inclusion is successful, LED will turn on within 2 seconds and Then will be in power indication mode, Otherwise, The LED will keep slow flash.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Smart Plug can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All non-battery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.Smart Plug is also a security Z-Wave device and supports the Over The Air (OTA) feature for the products firmware upgrade.If you want your Smart Plug to be a security device that use secure/encrypted message to communicate in a Z-Wave network, then a security enabled Z-Wave controller is needed.

Reset to factory default Reset Smart Plug to factory Default:1.Make sure that the Smart Plug has been connected to the power supply.2.Press and hold the Z-button for 5 seconds.3.If holding time is more than one second, the LED will blink faster and faster. If holding time is more than 5 seconds, the LED will be solid for 3 seconds to indicate that the resetting is successful. Otherwise, repeat step 2. Use this procedure only in the event that the network primary controller missing or otherwise inoperable.
Inclusion 1.Set the Z-Wave network main controller into learning mode.2.Short press the Z-button twice3.The LED keep blink to the end of add inclusion, If the add for inclusion is successful, LED will turn on within 2 seconds and Then will be in power indication mode, Otherwise, The LED will keep slow flash.
Exclusion 1.Set the Z-Wave network main controller into removing mode.2.Short press Z-button twice.3.The LED keep blink to the end of remove exclusion, If the remove for exclusion is successful, The LED will keep slow flash, Otherwise, LED will be in power indication mode.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 1. When the state of Smart Plug (turn on or off the load) is changed:1.Set Configuration parameter 0x03 to 0:Do not send Basic Report2. Set Configuration parameter 0x03 to 1: Send Basic Report3. Set Configuration parameter 0x03 to 2: Send Basic Report only when Load condition is changed not by Z-WAVE Command, such as short pressing.2. Sending Meter Report.

Configuration Parameters

Parameter 1: Over current protection

Smart Plug keep detecting the load power, once the AC current exceeds 16A for more than 5s, smart plug's relay will turn off.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled
1 The function is enabled.

Parameter 100: Setting the parameters 101~104 to the default value.

Setting the parameters 101~104 to the default value.
Size: 1 Byte, Default Value: 0

Setting Description
85 Setting the parameters 101~104 to the default value.

Parameter 101: Setting time for sending meter report (watt)

The interval time of sending meter report (watt) to associated device (Group Lifeline).
Size: 4 Byte, Default Value: 600

Setting Description
5 - 2678400 Available settings
0 The function is disabled.

Parameter 102: Setting time for sending meter report (KWh)

The interval of sending meter report (KWh) to association device (Group Lifeline).
Size: 4 Byte, Default Value: 3600

Setting Description
5 - 2678400 Available settings
0 The function is disabled.

Parameter 103: Setting time for sending meter report (voltage)

The interval of sending meter report (voltage) to association device (Group Lifeline).
Size: 4 Byte, Default Value: 0

Setting Description
5 - 2678400 Available settings
0 The function is disabled

Parameter 104: Setting time for sending meter report (current)

The interval time of sending meter report (current) to associated device (Group Lifeline).
Size: 4 Byte, Default Value: 0

Setting Description
5 - 2678400 Available settings
0 The function is disabled

Parameter 16: The value here represents minimum change in wattage (in terms of wattage) for a meter report to be sent

When the change value of load power exceeds the setting value, smart plug will send meter report (watt)to associated device (Group Lifeline).
Size: 2 Byte, Default Value: 50

Setting Description
1 - 65535 Available settings
0 The function is disabled.

Parameter 17: The value here represents minimum change in wattage percent (in terms of percentage) for a meter report (watt) to be sent

When the change value of the load power exceeds the setting value, smart plug will send meter report to associated device (Group Lifeline).
Size: 1 Byte, Default Value: 10

Setting Description
-128 - 127 Available setting
0 The function is disabled.

Parameter 2: Setting device status after power failure

Define how the Plug reacts after the power supply is back on.
Size: 1 Byte, Default Value: 0

Setting Description
0 Smart Plug memorizes its state after a power failure.
1 Connected device will be on after the power supply is reconnected.
2 Connected device will be off after the power supply is reconnected.

Parameter 254: Enable/disable the configuration command

Lock/unlock all configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock
1 Lock

Parameter 3: Notification when Load status change

Smart Plug can send notifications to associated device (Group Lifeline) when the status of smart plugs load is changed.
Size: 1 Byte, Default Value: 1

Setting Description
0 The function is disabled.
1 Send Basic report.
2 Send Basic report only when Load status is not changed by Z-WAVE Command.

Parameter 4: LED Load indicator mode selection

Configure LED Display mode to prevent light pollution at night.
Size: 1 Byte, Default Value: 0

Setting Description
0 The LED status follows the load change.
1 when operating the load, The LED lights for 5 seconds and then turns off.

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.00
Z-Wave Version 6.71.01
Certification ID ZC10-18015958
Z-Wave Product Id 0x0300.0x0200.0x000B
Supported Meter Type Electric Energy
Switch Type Push Button
Z-Wave Scene Type Scene
Firmware Updatable Updatable by Consumer by RF
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)On/Off Power Switch