Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
1.Remove the sensor cover. 2.Make sure the sensor is powered. 3.Set ZWave controller or ZWave gateway into inclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Presence detector and illuminance meter in one device. Zipato PIR motion sensor offers elaborate security and ambient sensing options.

Reset to factory default Reset procedure will delete all information on the ZWave network and ZWave controller or ZWave Gateway, and restore the sensor to factory default settings.1.Remove the device cover. 2.Make sure the sensor is powered. 3.Press and hold the button for 10 seconds, Led will blink once. 4.Release the button. Note: to use the reset procedure only when the primary controller is missing or inoperable.
Inclusion 1.Remove the sensor cover. 2.Make sure the sensor is powered. 3.Set ZWave controller or ZWave gateway into inclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times.
Exclusion 1.Remove the device cover. 2.Make sure the sensor is powered. 3.Set ZWave controller or ZWave gateway into exclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter exclusion mode.
NIF XXXNIF
Wakeup You can press the button once to wake up the device and send wakeup notification to controller. If press successfully, the LED will blink one time
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 4 Z-Wave Plus Lifeline
2 4 GROUP 2 allows for sending control commands to associated devices such as relay module, lighting, etc. This association group is configured through the advanced parameters no. 2, 3, 5 and 8. This Group Support: BASIC_SET
3 4 GROUP 3 allows for Send Notification to associated devices in this group. This Group Support: NOTIFICATION_REPORT_V4
4 4 GROUP 4 allows for Send Sensor Binary Report to associated devices in this group. This Group Support: SENSOR_BINARY_REPORT_V2

Configuration Parameters

Parameter 1: Sensitivity Level Setting

This parameter defines the sensitivity of PIR sensor. Its recommended to test thesensor with movements from the farthest end of the coverage area at the first timeof use. If movements cannot be detected sensitively, simply adjust the sensitivitylevel with this parameter. This parameter can be configured with the value of 8through 255, where 8 means high sensitivity and 255 means low sensitivity.
Size: 1 Byte, Default Value: 12

Setting Description
8 - 255 PIR sensitivity

Parameter 2: ON/OFF Duration

This parameter determines how long the associated devices should have ON status.For instance, if this parameter is set to 30 (sec), the PIR sensor will send aBASIC_SET command to associated device with value BASIC_SET level if PIR sensoris triggered and associated device will be turned on 30 seconds begore its turnedoff. This parameter value must be large as Parameter #. If user sets this parameterto default by Configure CC, the parameter # will be set to default value.
Size: 2 Byte, Default Value: 30

Setting Description
5 - 600 Seconds

Parameter 3: BASIC SET LEVEL

BASIC_SET command will be sent when PIR sensor is triggered. The receiver willtake it into consideration; for instance, if a lamp module is receiving the BASIC_SETcommand of which value is decisive as to how bright of dim level of lamp moduleshall be.
Size: 1 Byte, Default Value: 255

Setting Description
0 - 99 Dim level
255 Previous non zero dim level

Parameter 4: PIR DETECTION FUNCTION ENABLED / DISABLED

This parameter can enable or disable the PIR sensor detecting function.Function: Enabled / Disabled PIR function
Size: 1 Byte, Default Value: 255

Setting Description
0 DISABLE
255 ENABLE

Parameter 5: AMBIENT ILLUMINATION LUX LEVEL

This parameter can set Lux value which determines when the light sensor isactivated. If the ambient illumination level falls bellow this value and a person movesacross or within the detection area, PIR sensor will send Z-Wave ON command (i.e.BASIC_set (value = parameter 3) to an associated device and activate it.
Size: 2 Byte, Default Value: 100

Setting Description
0 - 1000 Lux

Parameter 6: RE-TRIGGER INTERVAL SETTING

This parameter can be used to adjust the interval of being re-triggered after the PIRsensor has been triggered. This parameter value must be less than Paramater #2.If user sets this parameter to default by Configure CC, the parameter #2 will be setto default value.
Size: 1 Byte, Default Value: 8

Setting Description
1 - 8 Retrigger interval in seconds

Parameter 7: LIGHT SENSOR POLLING INTERVAL

This parameter can set the light sensor to measure ambient illumination levelinterval time. NOTE: This value must be less than Wakeup Interval Time!
Size: 2 Byte, Default Value: 180

Setting Description
60 - 3600 Seconds

Parameter 8: 8

If this parameter is set to 1 and when Lux level is less than the value defined byparameter #5, PIR sensor will send a BASIC_SET command frame (i.e. BASIC_SET(value = parameter 3) to an associated device and activate it. If Lux level is greater than thevalue defined by parameter #5, PIR sensor will not send BASIC_SET command frame.
Size: 1 Byte, Default Value: 0

Setting Description
0 DISABLE
1 ENABLE

Parameter 9: AMBIENT ILLUMINATION LUX LEVEL REPORT

This parameter defines by how much Lux level must change in Lux to be reported tothe main controller.
Size: 2 Byte, Default Value: 1

Setting Description
0 - 1000 lux

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 66 FW: 3.80
Z-Wave Version 6.51.06
Certification ID ZC10-18015916
Z-Wave Product Id 0x0131.0x0003.0x1089
Sensors Luminance
Supported Notification Types Home Security
Color White
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor