This is a
1) Open the cover.2) Place the device within the direct range of your Z-Wave controller.3) Set the main controller in add mode (see the controllers manual).4) Click the Z-button once or triple click the Z-button quickly, the LED indicator should blink fast. 5) Wait for the adding process to end.6) Successful adding will be confirmed by the Z-Wave controllers message.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
LEAK SENSORis capable of both detecting leaks and floods and when the level of water gets too low in pool or tank, LEAK SENSOR can work with your z-wave network to prevent emergencies such as burst water boiler to leaking air conditioners. With Z-Wave, the scope to save money is endless.The features list:1)Z-Wave Plus certified for wide compatibility (500 serials product).2)Security 0 and security 2 framework implemented with AES-128 encryption.3)Contains an extension water detecting probe. 4)Temperature measurement.5)Vibration sensor.6)The battery life is up to 1 year. 7)Low battery alert
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
1) Power on the device2) Press and hold the Z button for more than 20 seconds,3) If holding time more than 20seconds, the LED indicator will keep on for 2 seconds, which means resetting is complete.4) The reset feature works only when the device has been included into a Z-Wave network.Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: Press and hold the Z button for more than 5 seconds and release.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline:1. Notification Report.Sensor will send Notification Report to the associated nodes 2. Battery Report.Sensor will send Battery Report when the battery level is low and the battery reports value is 0xFF.3. Device Reset Locally Notification.Sensor will send Device Reset Locally Notification when reset4.Sensor multilevel reportWhen associated to Group 1, you can adjust the temperature reporting cycle according to the configuration settings. |
2 | 5 | 1. Basic Set.Flood Sensor will send Basic Set to associated nodes when Water leak detected. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Flood sensor can send BASIC SET command to nodes associated with group 2. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Flood sensor can reverse its value of BASIC SET when flooding is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is triggered.Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is canceled. |
1 | Send BASIC SET VALUE = 0 to nodes associated with group 2 when flooding alarm is triggered.Send BASIC SET VALUE = 255 to nodes associated with group 2 when flooding alarm is canceled. |
Size: 1 Byte, Default Value: 5
Setting | Description |
---|---|
-128 - 127 | The higher the value, the long the report periodically - in hexadecimal values from 0x01 to 0xFF, or 1 to 255 if your controller allows unsigned decimal values. |
0 | Disable flooding alarm |
Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | when the value is 0, the product will not sends a vibration alarm after moving or shaking; when the value is 1, the product will sends a vibration alarm after moving or shaking |
The temperature changes at least 1 degree Celsius before reported. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
-128 - 127 | the higher the value ,the long the report time |
The precision of the temperature value is 1.Available settings(US):-670 - 2570-67257FAvailable settings(Other):-550 - 1250-55125CDefault setting (US): 1040 (104F)Default setting (Other): 400(40C) Size: 2 Byte, Default Value: 1040
Setting | Description |
---|---|
-670 - 2570 | the larger the value , the higher the high temperature(US) |
-550 - 1250 | the larger the value , the higher the high temperature(other) |
The precision of the temperature value is 1.Available settings(US):-670 - 2570-67257FAvailable settings(Other):-550 - 1250-55125CDefault setting (US): 320 (32F)Default setting (Other): 0 (0C) Size: 2 Byte, Default Value: 320
Setting | Description |
---|---|
-670 - 2570 | the smaller the value , the lower the low temperature(US) |
-550 - 1250 | the smaller the value , the lower the low temperature(other) |
0 Disable.1 Enable. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | when the value is 0, the product will not alarm when being triggered; when the value is 1, the product will alarm when being triggered |
This parameter defines a battery level as the low battery.Available settings: 10-50 (10% - 50%)Default setting: 20 (20%) Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
10 - 50 | Set the trigger value for the low battery alarm |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 2 FW: 1.01 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-17125906 |
Z-Wave Product Id | 0x000C.0x0201.0x000A |
Supported Notification Types | Heat AlarmHome SecurityWater Alarm |
Sensors | Air Temperature |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Security V2 | S2_UNAUTHENTICATED |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |