Quickstart

This is a secure Wall Controller for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Set primary controller/gateway into inclusion mode (Please refer to your primarycontrollers manual on how to turn your controller into inclusion).2. Make sure the wall controller does not belong to any Z-Wave network (please refer tothe part How to check whether the wall controller included to a network of this manual).3. Short press the inclusion/exclusion button, or press and hold down ALL ON/OFFbutton for over 3 seconds, the wall controller will be set to inclusion mode, and waiting tobe included, then LED indicator turns on and blinks 6 times quickly to indicatesuccessful inclusion.Once the wall controller quits inclusion mode, the LED indicator will turns off. Thereare 3 methods for the wall controller to quit inclusion mode:1. Automatically quits after successful inclusion.2. Quits after 25 seconds timeout.3. Press and hold down ALL ON/OFF button for over 3 seconds, or short press theinclusion/exclusion button to quit.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

The Wall controller is a Security Enabled Z-Wave Plus device that can both control other Z-Wave devices and activate scenes in Gateways. The wall controller can be included and operated in any Z-Wave network with other Z-Wave certified devices from other manufacturers and/or other applications. All nonbattery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.

Reset to factory default Press and hold down inclusion/exclusion button for over 8 seconds, LED indicator turns on and shows 3 short blinks and 1 long blink to indicate successful factory reset, release inclusion/exclusion button, the wall controller will restart automatically.If this controller is the primary controller for your network, resetting it will result in the nodes in your network being orphaned and it will be necessary after the reset to exclude and re-include all of the nodes in the network.If this controller is being used as a secondary controller in the network, use this procedure to reset this controller only in the event that the network primary controller is missing or otherwise inoperable.
Inclusion 1. Set primary controller/gateway into inclusion mode (Please refer to your primarycontrollers manual on how to turn your controller into inclusion).2. Make sure the wall controller does not belong to any Z-Wave network (please refer tothe part How to check whether the wall controller included to a network of this manual).3. Short press the inclusion/exclusion button, or press and hold down ALL ON/OFFbutton for over 3 seconds, the wall controller will be set to inclusion mode, and waiting tobe included, then LED indicator turns on and blinks 6 times quickly to indicatesuccessful inclusion.Once the wall controller quits inclusion mode, the LED indicator will turns off. Thereare 3 methods for the wall controller to quit inclusion mode:1. Automatically quits after successful inclusion.2. Quits after 25 seconds timeout.3. Press and hold down ALL ON/OFF button for over 3 seconds, or short press theinclusion/exclusion button to quit.
Exclusion There are two exclusion methods:Method 1: Exclusion from the primary controller/gateway as follows:1. Set the primary controller/gateway into exclusion mode (Please refer to your primarycontrollers manual on how to set your controller into exclusion).2. Short press the inclusion/exclusion button, or press and hold down ALL ON/OFFbutton for over 3 seconds, the wall controller will be set to exclusion mode, and waitingto be excluded, then LED indicator turns on and shows 3 short blinks and 1 long blink toindicate successful exclusion.Once the wall controller quits exclusion mode, the LED indicator will turns off. Thereare 3 methods for the wall controller to quit exclusion mode:1. Automatically quits after successful exclusion.2. Quits after 25 seconds timeout.3. Press and hold down ALL ON/OFF button for over 3 seconds, or short press theinclusion/exclusion button to quit.Method 2: Factory reset the wall controller will force the wall controller to be excludedfrom a network. (please refer to the part Factory Reset of this manual)
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus Lifeline;1. Send Command Class Device ResetLocally to associated devices of thisgroup to report factory reset informationwhen factory reset the wall controller.2. Double click a group number of the wallcontroller to send scene activationcommand to associated devices of thisgroup using Command Class CentralScene.
2 12 Press button u00221u0022 to activate group in orderto switch the associated devices with aBasic Set (by pressing the central buttononce) or dim these devices by using thefour lower buttons (or the dim wheelaround the central button).
3 12 Press button u00222u0022 to activate group in orderto switch the associated devices with aBasic Set (by pressing the central buttononce) or dim these devices by using thefour lower buttons (or the dim wheelaround the central button).
4 12 Press button u00223u0022 to activate group in orderto switch the associated devices with aBasic Set (by pressing the central buttononce) or dim these devices by using thefour lower buttons (or the dim wheelaround the central button).
5 12 Press button u00224u0022 to activate group in orderto switch the associated devices with aBasic Set (by pressing the central buttononce) or dim these devices by using thefour lower buttons (or the dim wheelaround the central button).

Technical Data

Hardware Platform ZM5101
Device Type Wall Controller
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.10
Z-Wave Version 6.71.01
Certification ID ZC10-17115883
Z-Wave Product Id 0x0330.0x0003.0xa10d
Firmware Updatable Updatable by Consumer by RF
Z-Wave Scene Type Central Scene
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Wall Controller