Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
-Press the Func_Buttom 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.-If Inclusion Process is successful, Green led will turn off.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Highly sensitive flood sensor keeping your home safe from any kind of water leakage or overflow. Separate design of body and sensor prevents the influence resulted from high humidity.

Reset to factory default - Long press Func_Buttom while installing batteries in the product. - Device Reset Locally notification is Transmitted.- Use the reset procedure only when the primary controller is missing or inoperable.
Inclusion -Press the Func_Buttom 3 times within 1.5s, Green LED is Blinking 3 times within 1 second.-If Inclusion Process is successful, Green led will turn off.
Exclusion -Press the Func_Buttom 3 times within 1.5s -If Exclusion Process is successful, Green led is Blinking 6 times, then turn off.
NIF XXXNIF
Wakeup -Wake up Notification is transmitted every 24 hours by default.-Wake up Notification is transmitted after Notification Report is Transmitted
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Association group 1: Lifeline association group - Maximum supported node is 1. Include command classes: Battery report, Notification report, and Device Reset Locally notification, Binary report.
2 5 Association group 2: Root Device group(Binary Sensor) Maximum supported nodes are 5. Binary Sensor Command Class: Compatible with 300 series 1-Binary Sensor reports status of water or no water via Lifeline. 2-When the sensor detects status change between water and no water, the device will be triggered.
3 5 Association group 3: Root Device group(Binary Sensor) Maximum supported nodes are 5. Binary Sensor Command Class:Compatible with 300 series 1-Binary Sensor reports the removed status of water sensor. 2-When the sensor detects status change of tamper, the device will be triggered.
4 5 Association group 4: Root Device group(Notification) Maximum supported nodes are 5. 1-Notification reports reports status of detect water or no water via Lifeline. 2-When the sensor detects status change between water and no water, the device will be triggered.
5 5 Association group 5: Root Device group(Notification) Maximum supported nodes are 5. 1-Binary Sensor reports the removed status of water sensor. 2- When the sensor detects status change of tamper, the device will be triggered.

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 14 FW: 2.00
Z-Wave Version 6.51.09
Certification ID ZC10-17115877
Z-Wave Product Id 0x0131.0x8004.0x1000
Supported Notification Types Water Alarm
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor