Quickstart
This is a
Notification Sensor for XXXQFrequencyName.
To run this device please make sure the internal battery is fully charged.
To add this device to your network execute the following action:
ADDING YOUR Z-WAVE UNITSDo not attempt to add your Z-Wave Module unless you are familiar with the operation of your Z-Wave Controller.1.Read the instructions for your Z-Wave Controller regarding adding new devices. Then initiate the inclusion function from your Z-Wave Controller.2.Triple-press the add button once the Z-Wave Module is on the device. The LED will show a quick blink once per second while the module is being added. This process may take as long as 30 seconds, but typically is much quicker. If you triple-press too quickly or too slowly, inclusion will not start. In this case wait a few seconds and then try again.3.Upon successful inclusion, the Z-Wave Module LED will flash 3 times. If inclusion fails, the LED will simply stop its blink pattern.4.If inclusion does not succeed, restart at step 1.5.If successful, place the alarm on its base and wait at least 30 seconds.6.Press the alarms test button and verify the Z-Wave Controller receives Notification Reports.7.After the Z-Wave Module is included, you may define association groups or perform other configuration operations from the Z-Wave Controller.
Important safety information
Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law.
The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material.
Use this equipment only for its intended purpose. Follow the disposal instructions.
Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from
Z-Wave Alliance Product
data and may be incomplete. Please refer to the
Manufacturers Manual for more information.
Product Description
This wireless module is designed to be installed in a Z-Wave compatible heat alarm. Thermistek technology provides quick detection of rapid temperature increases. Its reaction to heat rather than smoke makes it ideal for installation in kitchen areas and garages in order to avoid false alarms caused by cooking and vehicle fumes.The alarm sensor has a 10 year sealed for life Panasonic battery inside that will power the alarm for life. The Z-Wave module has a 2 year removable CR2 battery.When the wireless module is fitted into a Z-Wave compatible smoke or heat alarm it enables the unit to be wirelessly interlinked to a third party Z-Wave Controller. When any of the interlinked products are triggered by smoke or heat, the unit will transmit messages to the main Controller.
Reset to factory default |
FACTORY RESET YOUR Z-WAVE UNITS This operation should only be performed if the module is to be excluded from the network and if the Z-Wave Controller is also being reset or removed. 1.Press and hold the button for 10 seconds. The LED will go off. Now release the button. The LED will flash once as the module resets. 2.After resetting, either a) include the module into a different Z-Wave Controller, or b) remove the battery from the module to avoid power draining. * use the reset procedure only when the primary controller is missing or inoperable. |
Inclusion |
ADDING YOUR Z-WAVE UNITSDo not attempt to add your Z-Wave Module unless you are familiar with the operation of your Z-Wave Controller.1.Read the instructions for your Z-Wave Controller regarding adding new devices. Then initiate the inclusion function from your Z-Wave Controller.2.Triple-press the add button once the Z-Wave Module is on the device. The LED will show a quick blink once per second while the module is being added. This process may take as long as 30 seconds, but typically is much quicker. If you triple-press too quickly or too slowly, inclusion will not start. In this case wait a few seconds and then try again.3.Upon successful inclusion, the Z-Wave Module LED will flash 3 times. If inclusion fails, the LED will simply stop its blink pattern.4.If inclusion does not succeed, restart at step 1.5.If successful, place the alarm on its base and wait at least 30 seconds.6.Press the alarms test button and verify the Z-Wave Controller receives Notification Reports.7.After the Z-Wave Module is included, you may define association groups or perform other configuration operations from the Z-Wave Controller. |
Exclusion |
REMOVING YOUR Z-WAVE UNITS1.Read the instructions on your Z-Wave Controller regarding removing devices. Note that a device can be removed using any Z-Wave Controller, not just the Controller that was used to add the Module. Initiate the removal process at your Controller.2.Triple-press the button on the Z-Wave Module. The LED will show a quick double-blink once per second while the module is being removed. This process may take up to 30 seconds. If you triple-press too quickly or too slowly the removing function will not start. In this case you must wait a few seconds and then try again.3.Upon successful removal, the Z-Wave Module LED will flash 5 times. If removal fails, the LED will simply stop its blink pattern.4.If the removal operation does not succeed, restart at step 1.5.After removing, either a) add the Z-Wave Module into a different Z-Wave Controller, or b) remove the battery from the Z-Wave Module.NOTE: The effective range of the wireless module may be reduced by walls and other obstructions in the building. It is recommended not to exceed 40m as the maximum distance between smoke alarms and the Controller. |
NIF |
XXXNIF |
Wakeup |
Waking the ModuleIf the module has been successfully included, when pressing the button, the LED will flash three times. In addition, the module will communicate with the Z-Wave Controller, accepting any pending commands. |
Protection |
XXXProtection |
FirmwareUpdate |
XXXFirmwareUpdate |
SetAssociation |
XXXSetAssociation |
Association Groups:
Group Number |
Maximum Nodes |
Description |
1 |
5 |
Z-Wave Plus Lifeline |
Technical Data
Hardware Platform |
ZM5101 |
Device Type |
Notification Sensor |
Network Operation |
Reporting Sleeping Slave |
Firmware Version |
HW: 255 FW: 1.04 |
Z-Wave Version |
6.51.07 |
Certification ID |
ZC10-17115844 |
Z-Wave Product Id |
0x026F.0x0002.0x0002 |
Sensors |
Heat |
Communications Connections |
Manufacturer Proprietary |
Supported Notification Types |
Heat Alarm |
Frequency |
XXfrequency |
Maximum transmission power |
XXantenna |