This is a
Keep pressing the button of the outlet, and then power up the outlet. The outlet will enter the factory test mode,in which all the operations of the outlet will not work and the green LED light will keep flashing.Exit from factory test mode: Power off, and then power the outlet on by un-pressing the button. And then itwill enter the normal working mode.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
This is a smart power plug, function includes Switch, Electrical parameters measure, Over-current protection & timing. Lets you wirelessly control whatever device is plugged into it remotely, from a schedule, or from the outlet iteself. This smart switch has electrical parameters measure,you can see the electricity which your device are using in real time from APP.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
a) Ensure that the outlet is powered up correctly.b) Press the button and maintain this action for 10 seconds, then release it after the green and red LEDs bothlight on. Then the outlet will restore all data to the factory defaults.Note: This mode can also delete the network information of the outlet and make the device exclude from the Z-Wave network that it has joined.Please use this procedure only when the network primary controller is missing or otherwise inoperable.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline Group, Support Command List as below:COMMAND_CLASS_SWITCH_BINARY, SWITCH_BINARY_REPORTCOMMAND_CLASS_METER, METER_REPORTCOMMAND_CLASS_NOTIFICATION, NOTIFICATION_REPORTCOMMAND_CLASS_DEVICE_RESET_LOCALLY, DEVICE_RESET_LOCALLY_NOTIFICATION |
2 | 5 | Control Group, If over-load is occured, the device will send BASIC_SET to nodes associated in group 2. Support Command List as Below:COMMAND_CLASS_BASIC, BASIC_SET |
3 | 5 | Power Manager Group. If Over-load is occured, device will send notification report to nodes associated in group 3. Support List as Below:COMMAND_CLASS_NOTIFICATION, POWERMANAGEMENT STATUS (OVER LOAD) |
As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:
Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.
If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.
To become primary a contoller have to be resetted and then include a device.
a) Ensure that the outlet is powered up correctly.b) Set Z-Wave Gateway entered inclusion mode.c) Press the button on the outlet for three times quickly within 1.5 seconds. Then the LED light will flash for5 times with an interval of 500ms, which means that the outlet has entered the inclusion mode and it iswaiting for the gateway to complete the configuration.
The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.
Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.
a) Ensure that the outlet is powered up correctly.b) Set Z-Wave Gateway entered exclusion mode.c) Press the button on the outlet for three times quickly within 1.5 seconds. Then the LED light will flash for5 times with an interval of 500ms, which means that the outlet has entered the mode of excluding from thenetwork and it is waiting for the gateway to complete the configuration.
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
This parameter is set as '1'. The switch will save the current switch state, and after the outlet is powered down and restarted, it will automatically recover to the switch state before power-down. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 0 - Disable, 1 - Enable |
Setting this parameter as '0' will make it invalid to operate the outlet switch with the button Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 0 - Disable, 1 - Enable |
Setting this parameter as '0' will forbid the LED of the outlet from being on; Parameter '0' is invalid to the LED indication in the power-up state. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 0 - Disable, 1 - Enable |
Setting this parameter as '1' will start the timing function of the outlet,and the length of time is determined by the setting of Parameter 5.This function can only provide the timed closing control function when the outlet is open. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | 0 - Disable, 1 - Enable |
This parameter sets the time length of closing the outlet at a fixed time,the unit of which is minute,which is only valid when Parameter 4 is set as '1'. Size: 2 Byte, Default Value: 150
Setting | Description |
---|---|
1 - 32767 | minute. the time interval for Timer |
Setting this parameter as '0' will close the timed report function of the outlet, with no influence on the current change reporting function. The interval of reporting electric quantity detection result is controlled by the time set by Parameter 7. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 - 1 | 0 - Disable, 1 - Enable |
This parameter is to set the interval of reporting electric quantity detection result, the unit of which is: Seconds. This parameter is only valid when Parameter 6 is set as '1'. Size: 1 Byte, Default Value: 300
Setting | Description |
---|---|
30 - 32767 | second. The timer interval for meter report |
This parameter sets the maximum output current that the outlet can provide,the unit of which is: Ampere (A).When the current consumed by the load is greater than the set value, the outlet will automatically cut off the power of the load and send out alarm information. Size: 1 Byte, Default Value: 16
Setting | Description |
---|---|
1 - 16 | The max output current value. (Ampere) |
This parameter sets the change volume of the load current (volatility). When the differences between two measurements of current consumed by the load exceed the value set by this parameter, the outlet will report the last electric quantity detection result automatically to the host, the unit of which is 0.01A.For example, when this parameter is set as 10, then 100.01A = 0.1A, which means that all results currently measured will be reported to the outlet automatically (voltage, current, instant power and cumulative power) when the difference between the current measured currently and the current reported last time is greater than 0.1A. Size: 2 Byte, Default Value: 50
Setting | Description |
---|---|
1 - 1600 | The current changed value for meter report. (0.01A) |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 16 FW: 1.36 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17105819 |
Z-Wave Product Id | 0x0331.0x0003.0x1D61 |
Switch Type | Toggle |
Supported Notification Types | Power Management |
Supported Meter Type | Electric Energy |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |