This is a
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action Button that you can find on the product.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Oomi by Fantem Water Sensor brings intelligence to a new level, one that is suited to both safety and convenience. It contains 4 sensing points, which would be more accurately to detect the presence and absence of water or detect whether there is water leak in some places of your home. The Water Sensor has an inbuilt buzzer that can play alarm sounds to let you know when the water is detected.The Water Sensor is also a security Z-Wave device that supports Over The Air (OTA) for firmware updates.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
Press and hold the Action Button that you can find on the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: Pressing the Action Button once will trigger sending the Wake up notification command. If press and hold the Z-Wave button for 3 seconds, the Water Sensor will wake up for 10 minutes.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifelinegroup.1. The Battery Report or Multilevel Sensor Report (Configurable) can be sent to the associated nodes in group 1.2. When the water leak is detected, the Notification Report will be send to the associated nodes in group 1.3. When the Water Sensor is reset, the Device Reset Locally CC will be send to the associated nodes in group 1. |
2 | 5 | Send the configuration parameter 0x88 to the associated nodes in group 2. |
3 | 5 | Send Basic Set (configured by parameter 0x58) to the associated nodes in Group 3 when the Sensor probe 1 is triggered. |
4 | 5 | Send Basic Set (configured by parameter 0x59) to the associated nodes in Group 4 when the Sensor probe 2 is triggered. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Set the alarm time for the Buzzer when the sensor is triggered. Size: 4 Byte, Default Value: 101968650
Setting | Description |
---|---|
1 - 255 | Repeated cycle of Buzzer alarm. |
256 - 65535 | the time of Buzzer keeping ON state (MSB) |
65536 - 2147483647 | The time of Buzzer keeping OFF state |
To set what unsolicited report would be sent to the Lifeline group. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 | Send Nothing |
1 | Battery Report is enabled. |
2 | Multilevel sensor report for temperature is enabled. |
3 | Battery Report and Multilevel sensor report for temperature are enabled. |
To set the interval time of sending reports in Report group 1.Note:1. The unit of interval time is second if USB power.2. If battery power, the minimum interval time is equal to Wake Up interval set by the Wake Up CC. Size: 4 Byte, Default Value: 3600
Setting | Description |
---|---|
5 - 2678400 | Available rang is 5 to 2678400 seconds. |
To set which sensor report can be sent when the water leak event is triggered and if the receiving device is a non-multichannel device. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Send nothing |
1 | Send notification report to association group 1. |
2 | Send configuration 0x88 report to association group 2. |
3 | Send notification report to association group 1 and Send configuration 0x88 report to association group 2. |
When the parameter 0x87 is set to 2 or 3, it can get the sensor probes status through this configuration value.Note: This parameter is a Get- only parameter. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | absence of water is triggered by probe 1. |
1 | presence of water is triggered by probe 1. |
2 | presence of water is triggered by probe 2. |
Enable/Disable waking up for 10 minutes when re-power on (battery mode) the MultiSensor. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable. |
Temperature sensor calibration.Note:1.High byte is the calibration value. Low byte is the unit (0x00=Celsius, 0x01=Fahrenheit)2.The calibration value (high byte) contains one decimal point. E.g. if the value is set to 20 (0x1400), the calibration value is 2.0(EU/AU version) or if the value is set to 20 (0x1401), the calibration value is 2.0 (US version)3.The calibration value (high byte) = standard value - measure value.E.g.If measure value =25.3 and the standard value = 23.2, so the calibration value= 23.2 - 25.3= -2.1 (0xEB).If the measure value =30.1 and the standard value = 33.2, so the calibration value= 33.2 - 30.1=3.1 (0x1F). Size: 2 Byte, Default Value: 1
Setting | Description |
---|---|
-128 - 127 | Available rang is -12.8 to 12.7. |
Enable/disable all configuration parameters to be locked. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable. |
Reset to factory defaults. Size: 4 Byte, Default Value: 0
Setting | Description |
---|---|
1 | Reset all configuration parameters to factory defaults. |
1431655765 | Reset the product to factory defaults. |
Configure the default low battery value. When the current battery level is lower than this value, it will send out the low battery alarm. Size: 1 Byte, Default Value: 20
Setting | Description |
---|---|
10 - 50 | Available rang is 10% to 50%. |
Enable/disable the sensor report. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Disable |
1 | Enable. |
Set the upper limit value (overheat). Size: 4 Byte, Default Value: 68157696
Setting | Description |
---|---|
0 | Celsius unit |
1 | Fahrenheit unit |
65536 - 2147483647 | Temperature value |
Set the lower limit value (under heat) Size: 4 Byte, Default Value: 20971776
Setting | Description |
---|---|
0 | Celsius unit |
1 | Fahrenheit unit |
65536 - 2147483647 | Temperature value |
Note:1. When the current measurement <= (Upper limitRecover limit), the upper limit report is enabled and then it would send out a sensor report when the next measurement is more than the upper limit. After that the upper limit report would be disabled again until the measurement <= (Upper limitRecover limit).2. When the current measurement >= (Lower limit + Recover limit), the lower limit report is enabled and then it would send out a sensor report when the next measurement is less than the lower limit. After that the lower limit report would be disabled again until the measurement >= (Lower limit + Recover limit).3. High byte is the recover limit value. Low byte is the unit (0x01=Celsius, 0x02=Fahrenheit). Size: 2 Byte, Default Value: 5121
Setting | Description |
---|---|
10 - 255 | Available range is 1.0 to 25.5 |
Set the default unit of the automatic temperature report in parameter 101-103. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | The unit is Celsius. |
1 | The unit is Fahrenheit. |
Set the timeout of awake after the Wake Up CC is sent out. Size: 1 Byte, Default Value: 30
Setting | Description |
---|---|
8 - 127 | Available rang is 8 to 127 seconds. |
Get the state of tilt sensor.Note: this is a Get-only parameter. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | The Water Sensor main unit is in horizontal direction. |
1 | The Water Sensor main unit is in vertical direction. |
Enable/ disable the buzzer. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
To set which sensor is triggered the buzzer will alarm. Size: 4 Byte, Default Value: 55
Setting | Description |
---|---|
1 | If the Water leak is triggered, the buzzer will alarm. |
2 | If the vibration is triggered, the buzzer will alarm. |
4 | If the tilt sensor is triggered, the buzzer will alarm. |
16 | If the under heat is triggered, the buzzer will alarm |
32 | If the overheat is triggered, the buzzer will alarm. |
To set which value of the Basic Set will be sent to the associated nodes in association Group 3 when the Sensor probe 1 is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send nothing |
1 | Presence of water, send Basic Set 0xFF, absence of water, send Basic Set 0x00. |
2 | Presence of water, send Basic Set 0x00, absence of water, send Basic Set 0xFF. |
To set which value of the Basic Set will be sent to the associated nodes in association Group 4 when the Sensor probe 2 is triggered. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Send nothing. |
1 | Presence of water, send Basic Set 0xFF, absence of water, send Basic Set = 0x00. |
2 | Presence of water, send Basic Set 0x00, absence of water, send Basic Set 0xFF. |
Report the current power mode and the product state for battery power mode.Note: this parameter cannot be used as Set usage. Size: 2 Byte, Default Value: 0
Setting | Description |
---|---|
0 | USB power mode |
256 | Keep sleep state for Battery power mode |
257 | Keep awake for 10 minutes for battery power mode. |
To set which power source level is reported via the Battery CC. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | report the USB power level. |
1 | report the CR123A battery level. |
Hardware Platform | ZM5101 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 122 FW: 1.03 |
Z-Wave Version | 6.51.09 |
Certification ID | ZC10-17105817 |
Z-Wave Product Id | 0x016A.0x0302.0x007A |
Supported Notification Types | Heat AlarmHome SecurityWater Alarm |
IP (Ingress Protection) Rated | ok |
Sensors | Air TemperatureWater Flow |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |