Include or exclude the ZDS-210 from the existing Z-Wave home control network with your primary controller.-Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.-When prompted by your primary controller, triple click the PROG button within 1 second.(The unit will enter classical inclusion/exclusion first, then jump to NWI, and after 20 seconds, it will finally exit NWI mode automatically if there is no inclusion/exclusion request.)-The primary controller should indicate that the action was successful. If the controller indicates the action was unsuccessful, please repeat the procedure.
ZDS-210 enabled product allows users to remotely control lighting, home appliance, and make home control easy with low installation and maintenance costs. You may begin with a few Z-Wave enabled devices as well as some of our products to build up a complete home automation system.The ZDS-210 is a Z-Wave enabled device and is fully compatible with any Z-Wave Plus enabled network. It can be configured as either a DIMMER or a SWITCH device. It allows remote Dimming or ON/OFF control of specified lamps. Each module is designed to act as a repeater, which will re-transmit a radio frequency (RF) signal by routing the signal around obstacles and radio dead spots to ensure that the signal is received at its intended destination.ZDS-210 is a security enabled Z-Wave plus device. A security Enabled Z-Wave Plus Controller must be used in order to fully utilize the product.
Reset to factory default | Step 1: Press and keep holding the PROG button for no less than 10 seconds. LED state will toggle for first 5 seconds of being pressed.LED state will toggle again after the remaining 5 seconds.Step 2: Release the PROG button then triple click the PROG button within 2 seconds of step 1.LED will stay in previous ON or OFF stage.Remark : Please use this procedure only when the network primary controller is missing or otherwise inoperable. |
Inclusion | Include or exclude the ZDS-210 from the existing Z-Wave home control network with your primary controller.-Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.-When prompted by your primary controller, triple click the PROG button within 1 second.(The unit will enter classical inclusion/exclusion first, then jump to NWI, and after 20 seconds, it will finally exit NWI mode automatically if there is no inclusion/exclusion request.)-The primary controller should indicate that the action was successful. If the controller indicates the action was unsuccessful, please repeat the procedure. |
Exclusion | Include or exclude the ZDS-210 from the existing Z-Wave home control network with your primary controller.-Refer to your primary controller instructions to process the inclusion / exclusion setup procedure.-When prompted by your primary controller, triple click the PROG button within 1 second.(The unit will enter classical inclusion/exclusion first, then jump to NWI, and after 20 seconds, it will finally exit NWI mode automatically if there is no inclusion/exclusion request.)-The primary controller should indicate that the action was successful. If the controller indicates the action was unsuccessful, please repeat the procedure. |
NIF | XXXNIF |
Wakeup | XXXWakeupDescription |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 1 | Association group_1 (max. 1 node) is default to associate with the primary controller (Gateway/Hub/Controller) for ZDS-210 Status change report, refer to below for report details:ZDS-210 will trigger AUTO report function if the Dimmer or Switch status had been changed.Device Reset Locally Notification(Only report when the ZDS-210 Dimming Switch Module has been triggered the RESET TO DEFAULT) |
2 | 4 | Dimmer mode: After receiving a dimming command from a local switch or gateway (e.g. 50%), the ZDS-210 will automatically send out a related basic set command (e.g. 50%) to its associated group.Switch mode: After receiving a basic set command from a local switch or gateway, On (0xFF) or Off (0x00), the ZDS-210 will automatically send out a related basic set command, On (0xFF) or Off (0x00) to its associated group.(Max. 4 node ID's can be assigned to this association group) |
Double Click Option (Set to max. brightness)0 (0x00) - Double click function disabled1 (0x01) - Double click function enabled Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Disable |
1 | Enable |
Time to move the Dimmer from 0% to max. dimming values.(The ZDS-210 will implement the dimming duration if received this parameter value from controller/gateway. Otherwise, the ZDS-210 will implement the local parameter value) Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
0 - 5 | Seconds |
Maximum Dimmer level control2 (0x02) to 99 (0x63) % Size: 1 Byte, Default Value: 99
Setting | Description |
---|---|
2 - 99 | Dimmer Level |
Minimum Dimmer level control1 (0x01) to 98 (0x62) %[Below are the recommended parameters for different loads.AC Motors:Parameter no. 18 max. = 99% Parameter no. 19 min. >= 60%Fluorescent Lamps, Fluorescent Tubes, Non-dimmable LEDs:Parameter no. 18 max. = 99% Parameter no. 19 min. = 98%Notes: 1) The maximum level must not be lower than the minimum level. 2) Parameter no. 17 MUST be set to 0] Size: 1 Byte, Default Value: 13
Setting | Description |
---|---|
1 - 98 | Dimmer Level |
0 (0x00) - Switch does not save the state after power failure, device returns to u0022offu0022 position1 (0x01) - Switch saves its state before power failure Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | Not Save |
1 | Save |
Hardware Platform | ZM5202 |
Device Type | Light Dimmer Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 0.32 |
Z-Wave Version | 6.71.01 |
Certification ID | ZC10-17085755 |
Z-Wave Product Id | 0x5254.0x8200.0x8131 |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Electric Load Type | Dimmable LEDFluorescentIncandescent |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |