Quickstart

This is a Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
1. Remove the sensor cover.2. Make sure the sensor is powered.3. Set ZWave controller or ZWave gateway into inclusion mode (Refer to the controller orgateway operating manual)4. Press the button three times within 1.5 second, the device will enter inclusion mode. And theLED will flash on and off alternately five times.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This product can be included and operated in any ZWave network with other ZWave certified devices from other manufacturers and/or other applications. All nonbattery operated nodes within the network will act as repeaters regardless of vendor to increase reliability of the network.In the Back casing, there is a button that is used to carry out include, exclude, wake up device or reset factory default settings.When power is first supplied, the LED will flash on and off alternately at one second intervals within 5 seconds if the detector has not been added a ZWave network. Please get familiar with the terms below before starting the operations.

Reset to factory default Reset procedure will delete all information on the ZWave network and ZWave controller or ZWave Gateway, and restore the sensor to factory default settings.1.Remove the device cover. 2.Make sure the sensor is powered. 3.Press and hold the button for 10 seconds, Led will blink once. 4.Release the button. Note: to use the reset procedure only when the primary controller is missing or inoperable.
Inclusion 1. Remove the sensor cover.2. Make sure the sensor is powered.3. Set ZWave controller or ZWave gateway into inclusion mode (Refer to the controller orgateway operating manual)4. Press the button three times within 1.5 second, the device will enter inclusion mode. And theLED will flash on and off alternately five times.
Exclusion 1. Remove the sensor cover.2. Make sure the sensor is powered.3. Set ZWave controller or ZWave gateway into inclusion mode (Refer to the controller orgateway operating manual)4. Press the button three times within 1.5 second, the device will enter inclusion mode. And theLED will flash on and off alternately five times.
NIF XXXNIF
Wakeup You can press the button once to wake up the device and send wakeup notification to controller. If press successfully, the LED will blink one time
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 4 GROUP 1 is lifeline service that assigned to Sensor (Motion detector) statusOpen/Close. Itenables the sensor to send reports and readings to ZWave Controller or ZWave Gatewaywhenever the sensor is triggered. This Group Support:NOTIFICATION_REPORT_V4SENSOR_BINARY_REPORT_V2SENSOR_MULTILEVEL_REPORT_V7BATTERY_REPORTDEVICE_RESET_LOCALLY_NOTIFICATION
2 4 GROUP 2 allows for sending control commands to associated devices such as relay module,lighting, etc. This association group is configured through the advanced parameters no. 2, 3, 5and 8. This Group Support:BASIC_SET
3 4 GROUP 3 allows for Send Notification to associated devices in this group. This GroupSupport: NOTIFICATION_REPORT_V4
4 4 GROUP 4 allows for Send Sensor Binary Report to associated devices in this group. This GroupSupport:SENSOR_BINARY_REPORT_V2

Special Operations as Z-Wave Controller

As long as this device is not included into a Z-Wave network of a different controller it is able to manage its own Z-Wave network as primary controller. As a primary controller the device can include and exclude other devices in its own network, manage associations, and reorganize the network in case of problems. The following controller functions are supported:

Inclusion of other devices

Communication between two Z-Wave devices only works if both belong to the same wireless network. Joining a network is called inclusion and is initiated by a controller. The controller needs to be turned into the inclusion mode. Once in this inclusion mode the other device needs to confirm the inclusion - typically by pressing a button.

If current primary controller in your network is in special SIS mode this and any other secondary controller can also include and exclude devices.

To become primary a contoller have to be resetted and then include a device.

1.Remove the sensor cover. 2.Make sure the sensor is powered. 3.Set ZWave controller or ZWave gateway into inclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter inclusion mode. And the LED will flash on and off alternately five times.

Exclusion of other devices

The primary controller can exclude devices from the Z-Wave network. During exclusion the relationship between the device and the network of this controller is terminated. No communication between the device and other devices still in the network can happen after a successful exclusion. The controller needs to be turned into the exclusion mode. Once in this exclusion mode the other device needs to confirm the exclusion - typically by pressing a button.

Attention: Removing a device from the network means that it is turned back into factory default status. This process can also exclude devices from it's previous network.

1.Remove the device cover. 2.Make sure the sensor is powered. 3.Set ZWave controller or ZWave gateway into exclusion mode (Refer to the controller or gateway operating manual) 4.Press the button three times within 1.5 second, the device will enter exclusion mode.

Configuration Parameters

Parameter 1: Sensitivity Level Setting

This parameter defines the sensitivity of PIR detector, it is recommended to test the detectorwith movements from a farthest end of the coverage area at first time of use. If movementscannot be detected sensitively, simply adjust the sensitivity level with this parameter. ThisParameter can be configured with the value of 8 through 255, where 8 means high sensitivity and255 means lowest sensitivity.
Size: 1 Byte, Default Value: 12

Setting Description
8 - 255 unsigned

Parameter 10: Led Blink Enable

This parameter defines the Led on/off enable. If this parameter is set to 1, the led blink will beenabled, the led will blink once when motion sensor detect a movement. Otherwise, the led willbe turned off always.
Size: 1 Byte, Default Value: 1

Setting Description
0 - 1 unsigned

Parameter 2: On/Off Duration Setting

This parameter can be determined how long the associated devices should stay ON status. Forinstance, this parameter is set to 30(second), the PIR detector will send a BASIC_SET Command toan associated device with value basic set level if PIR detector is triggered and the associateddevice will be turned on 30(second) before it is turned off. This Parameter value must be largethan Parameter 6#. If user set this parameter to default by Configure CC, the parameter #6 will beset to default value.
Size: 2 Byte, Default Value: 30

Setting Description
5 - 600 second. unsigned

Parameter 3: Basic Set Level

Basic Set Command will be sent where contains a value when PIR detector is triggered, thereceiver will take it for consideration; for instance, if a lamp module is received the Basic SetCommand of which value is decisive as to how bright of dim level of lamp module shall be. ThisParameter is used to some associated devices.
Size: 1 Byte, Default Value: 255

Setting Description
0 0, 1 ~ 99 or 255 0OFF, Alarm cancelling or turning a device off 1 ~ 99 or 255ON (Binary Switch Device) Dim Level (Multilevel Switch Device)

Parameter 4: Enabled/Disabled PIR Function

This parameter can be enabled or disabled the PIR detector detecting function.
Size: 1 Byte, Default Value: 255

Setting Description
0 Disable PIR Detector Function. unsigned
255 Enable PIR Detector Function. unsigned

Parameter 5: Lux Level Set

This parameter can be set a lux level value which determines when the light sensor is activated. Ifthe ambient illumination level falls below this value and a person moves across or within thedetected area , PIR detector will send a ZWave ON command(i.e. BASIC_SET (value = parameter3) to an associated device and activate it.
Size: 2 Byte, Default Value: 100

Setting Description
0 - 1000 Lux .unsigned

Parameter 6: Retrigger Interval Setting.

This Parameter can be used to adjust the interval of being retriggered after the PIR detector hasbeen triggered. This Parameter value must be less than Parameter 2#. If user set this parameterto default by Configure CC, the parameter #2 will be set to default value.
Size: 1 Byte, Default Value: 8

Setting Description
1 - 8 second .unsigned

Parameter 7: Light Sensor Polling Interval

This Parameter can be set the light sensor measure ambient illumination level interval time.NOTE: This Value Must Be less than Wakeup Interval Time.
Size: 2 Byte, Default Value: 180

Setting Description
60 - 36000 second .unsigned

Parameter 8: Lux Level Enable

If this parameter is set to 1, and when Lux level less than the value define by parameter #5, PIRdetector will send a BASIC_SET command frame(i.e. BASIC_SET (value = parameter 3) to anassociated device and activate it. If Lux Level greater than the value define by parameter #5, PIRdetector will not send a BASIC_SET command frame.
Size: 1 Byte, Default Value: 0

Setting Description
0 - 1 unsigned

Parameter 9: Lux Level Report

This parameter defines by how much Lux Level must change, in lux, to be reported to the maincontroller.
Size: 2 Byte, Default Value: 100

Setting Description
0 - 255 Lux. unsigned

Technical Data

Hardware Platform ZM5202
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 66 FW: 3.80
Z-Wave Version 6.51.06
Certification ID ZC10-17085750
Z-Wave Product Id 0x0266.0x0003.0x0300
Color White
Z-Wave Scene Type Scene
Firmware Updatable Updatable by Manufacturer
Supported Notification Types Home Security
Sensors Luminance
Communications Protocol Z-Wave Serial API
Communications Connections RS-232 (Serial)
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Notification Sensor