Quickstart

This is a secure Notification Sensor for XXXQFrequencyName. To run this device please make sure the internal battery is fully charged. To add this device to your network execute the following action:
Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action Button that you can find in the back of the product.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Aeon Labs Door/ Window Sensor 6 is a smart Z-Wave sensor that can detect the status of door/window's open/close in real time. Its a security Z-Wave device that supports security encryption. Also it supports the Over the Air Firmware Updating that allows you wirelessly update its firmware if needs. It can be included and operated in any Z-Wave network with other Z-Wave certified devices from manufacturers and/or other applications.

Reset to factory default Press the Action Button once that you can find in back of the product for 20 seconds and then release. This procedure should only be used when the primary controller is inoperable.
Inclusion Turn the primary controller of Z-Wave network into inclusion mode, short press the products Action Button that you can find in the back of the product.
Exclusion Turn the primary controller of Z-Wave network into exclusion mode, short press the products Action Button that you can find in back of the product.
NIF XXXNIF
Wakeup Press the Action Button once, which will trigger sending out the Wake up notification command, press and hold the Action Button for 3 seconds, which will toggle on/off the Sensor be waked up for 10 minutes.
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 5 Group 1 is assigned to the Lifeline association group and every device has 5 nodes to associate. The sensor binary report, basic set or notification report command can be sent in this group when the Sensor is triggered.

Configuration Parameters

Parameter 1: Which value of the Sensor Binary Report or Basic Set will be sent when the door is Opened/Closed.

To set which value of the Sensor Binary Report or Basic Set will be sent when the door is Opened/Closed.
Size: 1 Byte, Default Value: 1

Setting Description
0 Sensor Binary Report/Basic Set =0xFF when the door is opened, Sensor Binary Report/Basic Set= 0x00 when the door is closed.
1 Sensor Binary Report/Basic Set= 0x00 when the door is opened, Sensor Binary Report/Basic Set=0xFF when the door is closed.

Parameter 101: Enable/disable the function of parameter 111

Enable/disable the function of parameter 111.Note: this parameter cannot disable the low battery checking of the Sensor itself.
Size: 1 Byte, Default Value: 1

Setting Description
0 Disable.
1 Enable.

Parameter 111: Set the interval time of low battery checking.

Set the interval time of low battery checking.Note:1, if the value is less than 10, the time unit is second.If the value is more than 10, the time unit is 4 minutes, which means if the value is more than 10 and less than 240, the interval time is 4 minutes. If the value is more than 240 and less than 480, the interval is 8 minutes.2, if the current battery report falls below the low battery value (configurable parameter 39), it will send battery report=0xFF.
Size: 4 Byte, Default Value: 86640

Setting Description
0 - 2147483647 The range of interval can be set to 0 to 2147483647.

Parameter 121: To configure which sensor report will be sent when the door is opened/closed.

To configure which sensor report will be sent when the door is opened/closed.
Size: 1 Byte, Default Value: 1

Setting Description
1 Basic Set CC is selected.
2 Sensor Binary Report CC is selected.
3 Basic Set CC and Sensor Binary Report CC are selected.

Parameter 252: Lock/unlock all configuration parameters.

Lock/unlock all configuration parameters.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unlock.
1 Lock.

Parameter 255: Reset the Sensor.

Reset the Sensor.
Size: 4 Byte, Default Value: 0

Setting Description
0 Reset to default settings.
1431655765 Reset to default settings and excluded from the network.

Parameter 39: Set the low battery value.

Set the low battery value.(10% to 50%).
Size: 1 Byte, Default Value: 20

Setting Description
10 - 50 The range of low battery value can be set to 10% to 50%.

Technical Data

Hardware Platform ZM5101
Device Type Notification Sensor
Network Operation Reporting Sleeping Slave
Firmware Version HW: 112 FW: 1.03
Z-Wave Version 6.51.09
Certification ID ZC10-17085746
Z-Wave Product Id 0x0086.0x0302.0x0070
Sensors Open/Closed (Binary)
Supported Notification Types Access Control
Frequency XXfrequency
Maximum transmission power XXantenna
Hong KongNotification Sensor