Dies ist ein
Device Learn Mode : This mode is for factory default or service mode (curtain or blind mode), not used by user. * Entering this learn mode is some difficult, because this mode is only for factory or service mode.- Put curtain or blind at close position first with remote or electrical switch.- Press the program switch for 300(ms) and release it after 900(ms) as following. . When press & release the program switch at first time, LED will be blink one time.. When press & release the program switch at second time, LED will be blink two times.. When press & release the program switch at third time, LED will be blink three times- After LED blink three times, module will try device learn.- Open the curtain or blind. Then, close the curtain or blind.- This mode is to distinguish the device (curtain or blind) and measure the total distance between up and down in case of blind device.
Z-Wave ist der internationale Funkstandard zur Kommunikation von Geräten im intelligenten Haus. Dies ist ein Z-Wave Gerät und nutzt die im Quickstart angegebene Funkfrequenz.
Dank Z-Wave können Produkte unterschiedlicher Hersteller miteinander in einem Funknetz verwendet werden. Damit ist auch dieses Produkt mit beliebigen anderen Produkten anderer Hersteller in einem gemeinsamen Z-Wave Funknetz einsetzbar.
Wenn ein Gerät die spezielle sichere Kommunikation unterstützt dann wird es immer dann mit einem anderen Gerät sicher kommunizieren, wenn dieses Gerät auch eine sichere Kommunikation unterstützt. Ansonsten wird aus Kompatibilitätsgründen auf einen normalen Kommunikation umgeschaltet.
Weitere Informationen wie Produktneugkeiten, Tutorials, Supportforen etc. erhalten Sie auf www.zwave.de.
Z-Wave enabled devices displaying the Z-Wave logo can also be used with it regardless of the manufacturer, and ours can also be used in other manufacturers Z-Wave enabled networks. Users easily control the curtain to open and close by sending Z-Wave signal from Z-Wave Interface Controller. This module will send open/close signal to the appliance that attached to this module by receiving Z-Wave signal from controller or manually switch. Our special design the curtain not only can be opened and closed but also can be stopped under the Multilevel Switch command on the controller. When the device is secure included into Z-Wave network, above communication will be encrypted.This module also acts as repeater
Bitte lesen Sie die Benutzeranleitung bevor Sie das Gerät in Betrieb nehmen.
Damit ein Z-Wave zu einem neuen Netz hinzugefügt werden kann muss es sich im Auslieferungs- oder Reset-Zustand befinden. Im Zweifel ist es sinnvoll, eine Exklusion durchzuführen, um das Gerät ganz sicher in diesem Zustand zu bringen. Diese Exklusion kann von jedem beliebigen Z-Wave Controller durchgeführt werden.
Dieses Gerät kann auch ohne Hilfe eines Controller in den Reset-Zustand zurückgeführt werden. Dies sollte jedoch nur dann gemacht werden wenn der Primärcontroller des Z-Wave-Netzes nicht mehr verfügbar oder defekt ist.
Local Reset (Factory Default Reset )- Press the program switch for above 10 second, then the LED is blinked until program switch is released.- Release from the program switch.- Then, SY-IOT101 module will try local reset.- If local reset is succeeded, LED is blinked 5 times.- After blinking LED, SY-IOT101 will send the Device Reset Locally Notification command and reset to the factory default. - If local reset is failed, LED is turn off.* Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Achtung: Je nach nationalen Sicherheitsnormen kann es nur autorisierten und/oder ausgebildeten Techniker erlaubt sein, elektrische Installationen am Spannungsnetz vorzunehmen. Bitte informieren Sie sich vor der Installation über die Rechtslage.
Im Auslieferungszustand ist das Gerät mit keinem Z-Wave-Netz verbunden. Damit es
mit anderen Z-Wave Geräten kommunizieren kann, muss es in ein bestehendes Z-Wave Netz
eingebunden werden. Dieser Prozess wird bei Z-Wave Inklusion genannt. Geräte können
Netzwerke auch wieder verlassen. Dieser Prozess heißt bei Z-Wave Exklusion. Beide
Prozesse werden von einem Controller gestartet, der dazu in einen Inklusion- bzw.
Exklusion-Modus geschaltet werden muss. Das Handbuch des Controllers enthält
Informationen, wie er in diese Modi zu schalten ist. Erst wenn der Controller
des Z-Wave Netzes im Inclusion-Modus ist, können Geräte hinzugefügt werden.
Das Verlassen des Netzes durch Exklusion führt zum Rücksetzen dieses Gerätes
in den Auslieferungszustand.3>
Inklusion
Device Learn Mode : This mode is for factory default or service mode (curtain or blind mode), not used by user. * Entering this learn mode is some difficult, because this mode is only for factory or service mode.- Put curtain or blind at close position first with remote or electrical switch.- Press the program switch for 300(ms) and release it after 900(ms) as following. . When press & release the program switch at first time, LED will be blink one time.. When press & release the program switch at second time, LED will be blink two times.. When press & release the program switch at third time, LED will be blink three times- After LED blink three times, module will try device learn.- Open the curtain or blind. Then, close the curtain or blind.- This mode is to distinguish the device (curtain or blind) and measure the total distance between up and down in case of blind device.
Exklusion
Device Learn Mode : This mode is for factory default or service mode (curtain or blind mode), not used by user. * Entering this learn mode is some difficult, because this mode is only for factory or service mode.- Put curtain or blind at close position first with remote or electrical switch.- Press the program switch for 300(ms) and release it after 900(ms) as following. . When press & release the program switch at first time, LED will be blink one time.. When press & release the program switch at second time, LED will be blink two times.. When press & release the program switch at third time, LED will be blink three times- After LED blink three times, module will try device learn.- Open the curtain or blind. Then, close the curtain or blind.- This mode is to distinguish the device (curtain or blind) and measure the total distance between up and down in case of blind device.
Die folgenden kleinen Hinweise können bei Problemen im Z-Wave Netz helfen.
Z-Wave Geräte können andere Geräte direkt steuern. Diese direkte Steuerung heißt in Z-Wave Assoziation. In den steuernden Geräten muss dazu die Geräte-ID des zu steuernden Gerätes hinterlegt werden. Dies erfolgt in sogenannten Assoziationsgruppen. Eine Assoziationsgruppe ist immer an ein Ereignis im steuernden Gerät gebunden (Tastendruck oder Auslösen eines Sensors). Bei Eintritt dieses Ereignisses wird an alle in einer Assoziationsgruppe hinterlegten Geräte ein Steuerkommando - meist ein BASIC SET - gesendet.
Gruppen-Nummer | Max. Anzahl Geräte | Beschreibung |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
So lang dieses Gerät nicht als Sekundärcontroller in das Netz eines anderen Z-Wave Controllers inkludiert wurde, kann es selbst als Primärcontroller (Systemverwalter) ein Z-Wave-Netz aufbauen und managen. Dies beinhaltet das Inkludieren und Exkludieren von Geräten, das Erstellen und Löschen von Assoziationen sowie die Reorganisation des Netzes. Die folgenden Funktionen werden von diesem Controller unterstützt:
Zwei Z-Wave Geräte können nur dann miteinander kommunizieren, wenn sie sich in einem gemeinsamen Netz befinden. Der Vorgang, ein Gerät in ein Z-Wave Netz einzufügen heisst bei Z-Wave Inklusion und wird immer von einem Controller gestartet. Dieser wird dazu in den sogenannten Inklusion-Modus geschaltet. Die Inklusion wird durch das zu inkludierende Gerät bestätigt, meist durch Betätigen einer Taste. Um ein neues Gerät zum eigenen Netz hinzuzufügen, muss die folgende Aktion durchgeführt werden:
For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the SY-IOT101to your controller. To get in the inclusion mode. - Check if SY-IOT101 module is in exclusion mode.- Press the program switch for above 5 second, then, the LED is turned on.- Release from the program switch.- Then, SY-IOT101 module will try inclusion.- If inclusion is succeeded, LED is blinked 3 times.- If inclusion is failed, LED is turn off.
Der Controller kann Geräte aus dem Z-Wave-Netz entfernen. Durch diese Exklusion wird die Verbindung zwischen dem Gerät und dem Controller beendet und es ist keine Kommunikation mehr möglich. Für eine Exklusion wird der Controller in den Exclusion-Modus geschaltet und die Exclusion am Gerät - meist durch einen Tastendruck bestätigt.
Achtung: Das Entfernen eines Gerätes aus einem Netz setzt dieses Gerät wieder in den Auslieferungszustand zurück. Ein Gerät kann von jedem Controller zurückgesetzt (exkludiert) werden, auch wenn es vorher zu einem anderen Netz gehört hat.
For Exclusion removing from the network: Put the Z-Wave Interface Controller into exclusion mode, and following its instruction to add the SY-IOT101 to your controller. To get in the exclusion mode. - Check if SY-IOT101 module is in inclusion mode- Press the program switch for above 5 second, then the LED is turned on.- Release from the program switch. - Then, SY-IOT101 module will try inclusion.- If inclusion is succeeded, LED is blinked 3 times.- If exclusion is failed, LED is turn off.
Z-Wave Hardware Platform | ZM5101 |
Gerätetyp | Window Covering - Pos/End Aware |
Netzwerkfunktion | Always On Slave |
Firmware Version | HW: 1 FW: 39.16 |
Z-Wave Version | 6.61.00 |
Zertifizierungs-ID | ZC10-17075691 |
Z-Wave Produkt Id | 0x0047.0x2018.0x1805 |
Color | White |
Firmware Updatable | Updatable by Manufacturer |
Window Covering Control Features | Manual CalibrationPosition AwareSupports CurtainsSupports Horizontal Blinds/LouversSupports Left/Right MotionSupports Open/Close MotionSupports Up/Down Motion |
Communications Connections | Ethernet (Wireless/WiFi) |
Communications Protocol | Manufacturer Proprietary Protocol |
Frequenz | XXfrequency |
Maximale Sendeleistung | XXantenna |