This is a
For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZD2301 to your controller, to get in the inclusion mode. Press the program switch of ZD2301 for sending the NIF.After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZD2301 will go to sleep after 20 seconds.
The Visions wireless 4 in 1 Multi-Sensor (door window contact sensor, humidity sensor, temperature sensor, and light sensor) of the home security device. This multi-sensor sends Z-Wave signal when door or window is opened and closed or humidity, temperature, luminous change.When the device is secure included into Z-Wave network, above communication will be encrypted.
Reset to factory default | Factory Default Reset: *Open the rear cover to send the Alarm Report and then press the program switch 10 times in 10 seconds, ZD2301 will send the Device Reset Locally command and reset to the factory default. * Please use this procedure only in the event that the network primary controller is missing or otherwise inoperable. |
Inclusion | For Inclusion in (adding to) a network: Put the Z-Wave Interface Controller into inclusion mode, and following its instruction to add the ZD2301 to your controller, to get in the inclusion mode. Press the program switch of ZD2301 for sending the NIF.After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZD2301 will go to sleep after 20 seconds. |
Exclusion | For Exclusion from (removing from) a network: Put the Z-Wave Interface Controller into exclusion mode, and following its instruction to delete the ZD2301 from your controller.Press the program switch of ZD2301 for 1 second at least to be excluded. |
NIF | XXXNIF |
Wakeup | Use Wake Up command to set up the awaking time and send the wake up notification to controller.User can use command to change the auto wake up from 10 minutes to 1 week, Interval increment is 3 minutes. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Lifeline |
0x00 = C0x01 = F Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 - 1 | Choose F |
1~50 (Set up from 0.1C~5C) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 50 | Auto Temperature Report Interval from 0.1C~5C |
1~50 (Set up from 1%~50%) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 50 | Auto Humidity Report Intervalfrom 1%~50% |
0,5~50 (Set up from 0 for Off or 5%~50%) Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 50 | Auto Light Report Interval from Off or 5%~50% |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 5 FW: 6.01:10.01 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-17075681 |
Z-Wave Product Id | 0x0109.0x201F.0x1F10 |
Supported Notification Types | Access Control |
Sensors | Open/Closed (Binary) |
Color | White |
Firmware Updatable | Updatable by Consumer by RF |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |