Quickstart

This is a secure Window Covering - Pos/End Aware for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Connect module to power supply (with temperature sensor connected - if purchased),auto-inclusion (works for about 5 seconds after connected to power supply) orpress push button I1 three times within 3s (3 times change switch state within 3 seconds) orpress service button S (only applicable for 24 V SELV supply voltage) for more than 2 second.NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This Z-Wave module is used to control the motor of blinds, rollers, shades, venetian blinds, etcThe module can be controlled either through a Z-Wave network or through the wall switch. Precise positioning is supported for motors equipped with mechanical or electronic end switches. The module is designed to be mounted inside a flush mounting box, hidden behind a traditional wall switch. Module measures power consumption of motor and support connection of digital temperature sensor. It is designed to act as repeater in order to improve range and stability of Z-Wave network.

Reset to factory default press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply orpress service button S (only applicable for 24 V SELV supply voltage)for more than 6 second.NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Inclusion Connect module to power supply (with temperature sensor connected - if purchased),auto-inclusion (works for about 5 seconds after connected to power supply) orpress push button I1 three times within 3s (3 times change switch state within 3 seconds) orpress service button S (only applicable for 24 V SELV supply voltage) for more than 2 second.NOTE1: For auto-inclusion procedure, first set main controller into inclusion mode and then connect module to power supply.NOTE2: When connecting temperature sensor to module that has already been included, you have to exclude module first. Switch off power supply, connect the sensor and re-include the module.
Exclusion Connect module to power supply bring module within maximum 1 meter (3 feet) of the main controller,enable add/remove mode on main controller,press push button I1 five times within 3s (5 times change switch state within 3 seconds) in the first 60 seconds after the module is connected to the power supply orpress service button S (only applicable for 24 V SELV supply voltage)for more than 6 second.By this function all parameters of the module are set to default values and own ID is deleted.If push button I1 is pressed three times within 3s (or service button S is pressed more than 2 and less than 6 seconds) module is excluded, but configuration parameters are not set to default values. NOTE: Please use this procedure only when the network primary controller is missing or otherwise inoperable.NOTE: If the module is included with parameters 71 with value different to default and module reset is done, wait at least 30s before next inclusion
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 0 Z-Wave Plus Lifeline
2 16 Basic on/off - triggered at change of the input I1 state and reflecting its state.
3 16 Basic on/off - triggered at change of the input I2 state and reflecting its state.
4 16 Basic on/off - triggered at sensing moving direction of roller: up=FF, down=0.
5 16 Basic on/off - triggered at reaching roller position: bottom=FF, top=0.
6 16 Basic on/off - triggered at reaching roller position: bottom=FF, not bottom=0.
7 16 Multilevel set - triggered at changes of value of the Flush Shutter DC position.
8 16 Multilevel set - triggered at changes of value of slats tilting position.
9 16 Multilevel sensor report - triggered at change of temperature sensor.

Configuration Parameters

Parameter 10: Activate/deactivate functions ALL ON / ALL OFF

Flush Shutter responds to commands ALL ON / ALL OFF that may be sent by the main controller or by other controllers belonging to the system.
Size: 2 Byte, Default Value: 255

Setting Description
255 ALL ON active, ALL OFF active
0 ALL ON is not active ALL OFF is not activ
1 ALL ON is not active ALL OFF active
2 ALL ON active ALL OFF is not active

Parameter 110: Temperature sensor offset settings

Set value is added or subtracted to actual measured value by sensor.
Size: 2 Byte, Default Value: 32536

Setting Description
32536 Offset is 0.0 Degrees Celsius
1 - 100 Value from 0.1 Degrees Celsiusto 10.0 Degrees Celsius is added to actual measured temperature
1001 - 1100 Value from -0.1 Degrees Celsius to -10.0 Degrees Celsius is subtracted to actual measured temperature

Parameter 120: Temperature sensor reporting

If digital temperature sensor is connected, module reports measured temperature on temperature change defined by this parameter. Available configuration parameters (data type is 1 Byte DEC):default value 5 = 0,5C 0 - Reporting disabled1-127 = 0,1C - 12,7C, step is 0,1C
Size: 1 Byte, Default Value: 5

Setting Description
5 = 0,5 Degrees Celsius
0 Reporting disabled
1 - 127 = 0,1 Degrees Celsius - 12,7 Degees Celsius; step is 0,1 Degrees Celsius

Parameter 250: Unsecure / Secure Inclusion

Flush Shutter supports secure and unsecure inclusion. Even if the controller does not support security command classes, a dimmer could be included as unsecure and keep all the functionality.
Size: 1 Byte, Default Value: 0

Setting Description
0 Unsecure Inclusion
1 Secure Inclusion

Parameter 40: Power reporting in Watts on power change for Q1 or Q2

Set value means percentage, set value from 0100 = 0% - 100%.
Size: 1 Byte, Default Value: 10

Setting Description
0 Reporting disabled
1 - 100 = 1% - 100% Reporting enabled. Power report is send (push) only when actual power (in Watts) in real time changes for more than set percentage comparing to previous actual power in Watts, step is 1%. NOTE: if power changed is less than 1W, the report is not send (pushed), independent of percentage set.

Parameter 42: Power reporting in Watts by time interval for Q1 or Q2

Set value means time interval (032767) in seconds, when power report is send.
Size: 2 Byte, Default Value: 0

Setting Description
1 - 32767 = 1 second - 32767 seconds. Reporting enabled, power report is send with time interval set by entered value
0 Reporting disabled

Parameter 71: Operating modes

This parameter defines selection between two available operating modes.NOTE1: After parameter change, first exclude module (without setting parameters to default value) then wait at least 30s and then re include the module!
Size: 1 Byte, Default Value: 0

Setting Description
1 Venetian mode (up/down and slate rotation)
0 Shutter mode

Parameter 72: Slats tilting full turn time

This parameter defines the time necessary for slats to make full turn (180 degrees).
Size: 2 Byte, Default Value: 150

Setting Description
0 Tilting time disabled
2 - 32767 = 0,01seconds - 327,67 seconds
150 = 1,5 seconds

Parameter 73: Slats position

This parameter defines slats position after up/down movement through Z-wave or push-buttons.default value 1 0 - Slats return to previously set position only in case of Z-wave control (not valid for limit switch positions).1 - Slats return to previously set position in case of Z-wave control, push-button operation or when the lower limit switch is reached.
Size: 1 Byte, Default Value: 1

Setting Description
1 Slats return to previously set position in case of Z-wave control, push-button operation or when the lower limit switch is reached
0 Slats return to previously set position only in case of Z-wave control (not valid for limit switch positions)

Parameter 74: Motor moving up/down time

This parameter defines Shutter motor moving time of complete opening or complete closing.NOTE: Important is that the reference position to manually set moving time is always Shutter lower position!Set parameter 74 to 0 and move the Shutter (using up/down push buttons or main controller UI) to the lowest desired position. On this Shutter position, set parameter 74 to time for complete opening or complete closing. At this point Shutter can be moved up (open) for set time, but can't be moved down because this position is already set as lower Shutter position.To change Shutter lower position below already set (manual recalibration), parameter 74 must be set to 0 and repeat the procedure described above.In case Shutter has limit switches, but anyhow you would like to limit opening/closing position by time, you can still do it. In case you put time that is longer that opening/closing real time limited by limit switches, Shutter will stop at limit switch, but the module relay will switch off after define time, not by Shutter limit switch. Take in consideration that in this condition, the positioning with slider through UI will not show correct Shutter position.
Size: 2 Byte, Default Value: 0

Setting Description
0 Moving time disabled (working with limitswitches)
1 - 32767 = 0,1 seconds - 3276,7 seconds. After that time motor is stopped (relay goes to off state)

Parameter 76: Motor operation detection

Power threshold to be interpreted when motor reach the limit switch.
Size: 1 Byte, Default Value: 30

Setting Description
0 - 127 = 1-127 W. The value 0 means reaching a limit switch will not be detected

Parameter 78: Forced Shutter calibration

By modifying the parameters setting from 0 to 1 a Shutter enters the calibration mode.
Size: 1 Byte, Default Value: 0

Setting Description
1 Start calibration process (when calibration process is finished, completing full cycle - up, down and up, set the parameter 78 (Forced Shutter calibration) value back to 0

Parameter 85: Power consumption max delay time

This parameter defines the max time before motor power consumption is read after one of the relays is switched ON.If there is no power consumption during this max time (motor not connected, damaged or requires higher time to start, motor in end position) the relay will switch OFF. Time is defined by entering it manually.
Size: 1 Byte, Default Value: 30

Setting Description
30 = 3s
0 = time is set automatically
3 - 50 = 0,3seconds - 5seconds (100ms resolution)

Parameter 90: Time delay for next motor movement

This parameter defines the minimum time delay between next motor movement (minimum time between switching motor off and on again).
Size: 1 Byte, Default Value: 5

Setting Description
5 = 500ms
1 - 30 = 0,1seconds - 3seconds (100ms resolution)

Technical Data

Hardware Platform ZM5202
Device Type Window Covering - Pos/End Aware
Network Operation Always On Slave
Firmware Version HW: 2 FW: 6.04:06.05
Z-Wave Version 6.51.09
Certification ID ZC10-17065670
Z-Wave Product Id 0x0159.0x0003.0x0052
Supported Meter Type Electric Energy
Sensors Air TemperatureWater Temperature
Switch Type Push Button
Color Light Blue
Supported Notification Types Power Management
Frequency XXfrequency
Maximum transmission power XXantenna
U.S. / Canada / MexicoWindow Covering - Pos/End Aware