Quickstart

This is a Whole Home Meter - Simple for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.Pressing On/Off (Include) button three times within 2 seconds will enter inclusion mode.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

This product can be operated in any Z-Wave network with other Z-Wavecertifieddevicesfromothermanufacturers.Allnon-battery operated nodes within the network will act as repeaters regardlessofvendortoincreasereliabilityofthenetwork. ZipatoEnergyMetermonitorstotalelectricityconsumption of connected appliances and reports it to Zipato or any other Z-Wave enabled controller in real time. Small and compact size allowseasyinstallationinmajorityofelectricitydistribution boxes. It supports two loads upto 6000W each (@ 120V).

Reset to factory default Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.Pressing On/Off (Include) button three times within 2 seconds will enter inclusion mode.Within 1 second, press and hold On/Off (Include) button again for 5 seconds until LED is off.IDs are excluded.
Inclusion Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.Pressing On/Off (Include) button three times within 2 seconds will enter inclusion mode.
Exclusion Put your Z-Wave controller into exclusion mode by following the instructions provided by the controller manufacturer.Pressing On/Off (Include) button three times within 2 seconds will enter exclusion mode.Node ID has been excluded.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 LifelineFor group 1, the Micromodule will report (1) The sum of instant Power Consumption (Watt) read from CT1 and CT2 (2) The sum of accumulated Power Consumption (KWh) read from CT1 and CT2.
2 1 For group 2, the Micromodule will report (1) Instant Power Consumption (Watt) read from CT1 (2) Accumulated Power Consumption (KWh) read from CT1.
3 1 For group 3, the Micromodule will report (1) Instant Power Consumption (Watt) read from CT2 (2) Accumulated Power Consumption (KWh) read from CT2.

Configuration Parameters

Parameter 1: Watt Meter Report Period

Ifthesettingisconfiguredfor1hour(setvalue=720), Micromodulewillreportitsinstantpowerconsumptionevery 1hourtothenodeofcorrespondGroup.Themaximum intervaltoreportitsinstantpowerconsumptionis45hours (5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 5*720s=3600s=1hour

Parameter 2: KWH Meter Report Period

If the setting is configured for 1hour (set value =720), the PAB01 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 45 hours (5s*32767/3600=45hr).
Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 5*720s=3600s=1hour

Parameter 3: Slected End Point

If Controller not using Multi_Channel command class to access theendpointofMicromodule,youmayconfiguretheendpoint valuetoreacttheBasicCommandClass,BinarySwitch Command Class or Meter Command Class V3. 1. SELECTED ENDPOINT 1: Report the Meter Value as CT1+CT2. Defauly selected endpoint is 1.2. SELECTED ENDPOINT 2: Report the Meter Value of CT1.3. SELECTED ENDPOINT 3: Report the Meter Value of CT2.
Size: 1 Byte, Default Value: 1

Setting Description
1 1: CT1 and CT2
2 2: CT1
3 3: CT2

Parameter 4: Threshold of Current for Load Caution

Thisisawarningwhenthecurrentofloadoverthepreset threshold value, If the setting value is 750, when the load wattage of CT1 or CT2 over 7.5A, Micromodule will send current Meter Report command to the node of correspond Group.
Size: 2 Byte, Default Value: 750

Setting Description
10 - 750 750*0.01A=7.5A

Parameter 5: Threshold of KWH for Load Caution

This is a warning when the KWh of load over the preset threshold value, If the setting value is 10000, when the Accumulated Power ConsumptionofCT1orCT2overthisvalue,Micromodulewill sendKWhMeterReportcommandtothenodeofcorrespond Group, minum value is 1KWh and default value is 10000 kWh.
Size: 2 Byte, Default Value: 10000

Setting Description
1 - 10000 10000*1KWh = 10000KWh

Technical Data

Hardware Platform SD3502
Device Type Whole Home Meter - Simple
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.02
Z-Wave Version 6.51.06
Certification ID ZC10-17065646
Z-Wave Product Id 0x0131.0x0006.0x001A
Electric Load Type Incandescent
Firmware Updatable Updatable by Consumer by RF
Supported Meter Type Electric Energy
Color White
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Whole Home Meter - Simple