This is a
The device supports both the mechanism Network Wide Inclusion (which offers the possibility of inclusion in a network even though the device is not directly related to the controller) and the Normal Inclusion.If the device is in factory default configuration, the single click of one of the buttons, starts the Network Wide Inclusion process that lasts for a time between 15 and 30 seconds.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Eelecta Homepad is a 4 channels pushbutton with 1 integrated 10A 250V relay. Equipped with 5 Led for buttons feedback and relay status. The device can control electrical loads or dimmerable actuators. The module is controlled either through the Z-Wave network or a simple switch. Designed to replace your conventional switch and control the connected load. The device works with 3-wires system, so neutral is required.
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
To restore the device to the original factory configuration one of the following methods can be adopted:1. Remove the device from the Z-Wave network using the controller;2. Disconnect the device from the main power supply and reconnect it pressing consecutively six times one of its buttons within 1 minute from the device start. Please use this procedure only when the network primary controller is missing or otherwise inoperable.INFO: Upon removal, if the device (node) is included in a network it notifies to other devices its removal (Device Reset Locally Notification).If the device receives a notification of removal from part of another device in the network, the associations of the latter will be removed.
ATTENTION: only authorized technicians under consideration of the country-specific installation guidelines/norms may do works with mains power. Prior to the assembly of the product, the voltage network has to be switched off and ensured against re-switching.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | Z-Wave Plus Lifeline; Switch Binary Report or Device Reset Locally Notification are sent to the nodes in this association group. |
2 | 8 | On/Off control; Switch Binary/Push Button Set. |
3 | 8 | Dimming Control; Dimmer Set. |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Defines which button is related to the control ofthe local load. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
0 | None of the buttons controls the local load |
1 - 0 | Relay controlled by button 1 |
2 - 0 | Relay controlled by button 2 |
3 - 0 | Relay controlled by button 3 |
4 - 0 | Relay controlled by button 4 |
Defines in which cases the control of the linked devices will beactivated with a u0022clicku0022 of a configured button. In order to control devices linked to a group these devices have to belong to this group. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 0 | The possible associations will ignored and associated devices will be not controlled |
2 - 0 | The associated devices will always be controlled by a click of one of the four buttons |
3 - 0 | The associated devices will be controlled only from those buttons that arent associated to the local load |
This parameter allows you to control devices associated with the button in a predefined way and not depending on their current state or command sent previously. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Button 1 - on/off standard control |
1 - 0 | Button 1 - always on |
2 - 0 | Button 1 - always off |
4 - 0 | Button 2 - always on |
8 - 0 | Button 2 - always on |
16 - 0 | Button 3 - always on |
32 - 0 | Button 3 - always on |
64 - 0 | Button 4 - always on |
-128 - 0 | Button 4 - always on |
Defines which events trigger LED feedback.The value to be entered for this parameter its calculated as the sum of the values associated with the individual entities indicated intable. Size: 1 Byte, Default Value: 3
Setting | Description |
---|---|
1 - 0 | LED reporting state of the Relay |
2 - 0 | Feedback on press button |
4 - 0 | Feedback on notification received from Remote devices |
Status after device restart. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
1 - 0 | Local Relay close |
2 - 0 | Local Relay open |
4 - 0 | Keep status before power down |
Define which parameters will be set to FactoryDefaults. Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
1 - 0 | All and only the associations are reset |
2 - 0 | The associations are preserved while all other parameters of configuration will be reset to Factory defaults, except this one that remains unchanged |
3 - 0 | Device will be restarted |
4 - 0 | No action is carried out |
This parameter define the behaviour of the button between switch and dimmer functions. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Button 1 - Switch |
1 - 0 | Button 1 - Push button |
2 - 0 | Button 1 - Dimmer |
4 - 0 | Button 2 - Push button |
8 - 0 | Button 2 - Dimmer |
16 - 0 | Button 3 - Push button |
32 - 0 | Button 3 - Dimmer |
64 - 0 | Button 4 - Push button |
-128 - 0 | Button 4 - Dimmer |
This parameter set the Light intensity at switch on.This behaviour is only appliable to dimmer. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Button 1 - maximum brightness |
1 - 0 | Button 1 - fixed value 60% |
2 - 0 | Button 1 - previous value |
4 - 0 | Button 2 - fixed value 60% |
8 - 0 | Button 2 - previous value |
16 - 0 | Button 3 - fixed value 60% |
32 - 0 | Button 3 - previous value |
64 - 0 | Button 4 - fixed value 60% |
-128 - 0 | Button 4 - previous value |
This parameter allows you to set the ramp time during dimming. Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Button 1 - Seconds |
1 - 0 | Button 1 - 5 Seconds |
2 - 0 | Button 1 - 10 Seconds |
4 - 0 | Button 2 - 5 Seconds |
8 - 0 | Button 2 - 10 Seconds |
16 - 0 | Button 3 - 5 Seconds |
32 - 0 | Button 3 - 10 Seconds |
64 - 0 | Button 4 - 5 Seconds |
-128 - 0 | Button 4 - 10 Seconds |
Hardware Platform | ZM5202 |
Device Type | On/Off Power Switch |
Network Operation | Always On Slave |
Firmware Version | HW: 1 FW: 1.07 |
Z-Wave Version | 6.51.10 |
Certification ID | ZC10-17055608 |
Z-Wave Product Id | 0x031F.0x0001.0x1030 |
Neutral Wire Required | ok |
Electric Load Type | |
Firmware Updatable | |
Switch Type | |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |