This is a
1. Have Z-Wave Controller entered inclusion mode.2. Press test button three times within 1.5 seconds to enter the inclusion mode.3. After the adding was successful, the device will wake to receive the setting from Z-Wave Controller about 20 seconds.
Zipato Smoke Sensor (Z-Wave) is designed to give early warning of developing fires by giving off the alarm sounds from its build-in alarm horn, based on Z-Wave technology. Zipato Smoke Sensor is Z-Wave Plus product, it supports security, OTA and all other new features of 500 Series Z-Wave chipset.
Reset to factory default | Notice: Use this procedure only in the event that the primary controller is lost or otherwise inoperable.1. Have Z-Wave Controller entered inclusion mode.2. After the red LED flash 9 times, release the test button within 2 seconds.3. IDs are removed and all settings will reset to factory default. |
Inclusion | 1. Have Z-Wave Controller entered inclusion mode.2. Press test button three times within 1.5 seconds to enter the inclusion mode.3. After the adding was successful, the device will wake to receive the setting from Z-Wave Controller about 20 seconds. |
Exclusion | 1. Have Z-Wave Controller entered inclusion mode.2. Pressing test button three times within 1.5 seconds to enter the exclusion mode. Node ID has been removed. |
NIF | XXXNIF |
Wakeup | After device is added to the network, it will wake-up once per dayby default.When it wakes-up it will broadcast the WakeUp Notification message to the network, and wake-up 10 seconds to receive the setting commands. The wake-up interval minimum setting is 30 minutes, and maximum setting is 120 hours. Interval step is 30 minutes. If you want to wake-up device immediately, please press the button once. The device will wake-up for 10 seconds. |
Protection | XXXProtection |
FirmwareUpdate | XXXFirmwareUpdate |
SetAssociation | XXXSetAssociation |
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 8 | Z-Wave Plus Lifeline |
The interval time for auto report the battery level.0 means turn off auto report battery. Each tick means 30 minutes. The default value is 12(6 hours) Size: 1 Byte, Default Value: 12
Setting | Description |
---|---|
0 - 127 | The interval time for auto report the battery level. |
Customer function switch, using bit control Size: 1 Byte, Default Value: 4
Setting | Description |
---|---|
4 | Notification type 0: Using Notification Report 1: Using Sensor Binary Report |
Hardware Platform | SD3502 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 1 FW: 1.23:01.24 |
Z-Wave Version | 6.51.02 |
Certification ID | ZC10-17055607 |
Z-Wave Product Id | 0x0131.0x0002.0x001E |
Supported Notification Types | |
Color | |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |