Quickstart

This is a Window Covering - Pos/End Aware for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.Pressing Include button three times within 2 seconds will enter inclusion mode.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Using Micromodule Motor Controller user can control connected rollershuttersandblinds,finelyadjusttheirpositionwithhis Z-Wave controller, Z-Wave remote or simple push of a button.MicromoduleMotorControllerisZ-WavePlusenableddevice whichmakesitcompatiblewithanyZ-Waveenablednetwork, regardless of the manufacturer. Slim design makes it easy to fit in majority of wall boxes. New smart-relay calibration technology reduces inrush current caused by the load and enables module to work perfectly with all kinds of roller shutters and blinds. Micromodule is able to detect position of the Shutter by using thepatternedpowermeasuringmethod,soitcanberemote controlled not only fully up or down, but also can be adjusted to ex. 30% or 50%. When manually operated by the push button, Micromodule Motor Controllercanalsomemorizethepositionandsendthenew shutter position to its controller (ex. IP-Gateway).

Reset to factory default Use this procedure only in the event that the network primary controller is missing or otherwise inoperable.Pressing Include button three times within 2 seconds will enter inclusion mode.Within 1 second, press Include button again for 5 seconds until LED is off.IDs are excluded.
Inclusion Put your Z-Wave controller into inclusion mode by following the instructions provided by the controller manufacturer.Pressing Include button three times within 2 seconds will enter inclusion mode.
Exclusion Put the Z-Wave Controller in exclusion mode.Pressing Include button three times within 2 seconds will enter exclusion mode.Node ID has been excluded.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 LifelineThere is only one group called Group1, there is only one node for Group1 which support MULTILEVEL_SWITCH_REPORT, METER_REPORT_COMMAND_V3, ALARM_REPORT.

Configuration Parameters

Parameter 1: Watt Meter Report Period

Ifthesettingisconfiguredfor1hour(setvalue=720),the Micromodulewillreportitsinstantpowerconsumptionevery 1hourtothenodeofcorrespondingGroup.Themaximum intervaltoreportitsinstantpowerconsumptionis45hours (5s*32767/3600=45hr). Default value is 1 hour.
Size: 2 Byte, Default Value: 720

Setting Description
1 - 32767 5*720s=3600s=1 hour

Parameter 2: KWH Meter Report Period

Ifthesettingisconfiguredfor1hour(setvalue=6),the MicromodulewillreportitsAccumulatedPowerConsumption (KW/h)every1hourtothenodeofcorrespondingGroup.The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). Default value=1 hour.
Size: 2 Byte, Default Value: 6

Setting Description
1 - 32767 6*10min= 1 hour

Parameter 3: Threshold of current for Load Caution

This is a warning when the wattage of load exceeds the preset thresholdvalue,Ifthesettingvalueis500,whentheload currentoverthisvalue,Micromodulewillsendcurrentmeter reportcommandtothenodeofcorrespondingGroup.Default value=500.
Size: 2 Byte, Default Value: 500

Setting Description
10 - 500 500*0.01=5 A

Parameter 4: Threshold of KWH for Load Caution

This is a warning when the KWh of load over the preset threshold value,Ifthesettingvalueis10000,whentheAccumulated PowerConsumptionofRelay1orRelay2overthisvalue, Micromodule will send KWh Meter Report command to the node ofcorrespondingGroup,minimumvalueis1KWhanddefault value is 10000 kWh.
Size: 2 Byte, Default Value: 10000

Setting Description
1 - 10000 10000*1KWh=10000KWh

Parameter 5: External switch type

1.ONE PUSH BUTTONWhen the configuration setting is One Push Button, only S1 input will be valid. The control moving commands can be accepted in this switch type while the shutter is moving. In this switch type, theinclusion/exclusion/reset/associationfunctioncanalsobe fulfilled by pressing S1 just like the operation of include button. WhenS1isshortpressed,theshutterwillmoveuptoward TOP(0xFF). If during this movement S1 is short pressed again, the shutter will stop moving. A third short pressing of S1 will move the shutter down toward BOTTOM(0x00). If during this movement S1 is short pressed again, the shutter will stop moving. And so on Inverting direction and stopping.2.TWO PUSH BUTTON: (THE DEFAULT SETTING IS TWO PUSH BUTTON (2))IfthissettingisconfiguredasTwoPushButton,S1andS2 input will be valid, but will not accept pressing S1 and S2 at the sametime.Inthisswitchtype,theinclusion/exclusion/reset/association function can also be fulfilled by pressing S1 or S2 just like the operation of include button. When S1 is pressed and held more than 1.5 seconds, the shutter will move up toward TOP(0xFF), and the shutter will stop moving when S1 is released. When S2 is pressed and held for more than 1.5 seconds, the shutter will move down toward BOTTOM(0x00), and the shutter will stop moving when S2 is released.WhenS1isshortpressed,theshutterwillmoveuptoward TOP(0xFF). If during this movement S1 i short pressed again S1 again, the shutter just keep moving up toward TOP(0xFF). The easy way to stop this moving is short pressing S2. When S2 is short pressed, the shutter will move down toward BOTTON(0x00). If during this movement S2 is short pressed again S2 again, the shutter just keep moving down toward BOTTON(0x00). The easy way to stop this moving is short pressing S1. When in Two Push Button switch type, S1 or S2 are pressed and not released, and PAN08 receive any control moving command from Z-Wave RF (Ex. BASIC_SET, BINARY_SWITCH_SET, MULTILEVEL_SWITCH_SET, MULTILEVEL_SWITCH_START_LEVEL_CHANGE or MULTILEVEL_SWITCH_STOP_LEVEL_CHANGEorSCENE_ACTIVATION_SET),PAN08wontdoanychangeinpositionbut report alarm to Group1 (Alarm_Type=1, Alarm_level =0xFF), this indicate that the S1 or S2 not been release.
Size: 1 Byte, Default Value: 1

Setting Description
1 1: One Push button
2 2:Two Push button

Parameter 6: Level report mode

Mode 1 : In 5 seconds period after controlled by a moving command, it will report the destination level when received request command. Out of the 5 seconds period, it will report the actual level of the shutter when received request command.Mode 2 : Whenever the shutter moves past a 10 percent level, it will auto report the level to Group 1 node.
Size: 1 Byte, Default Value: 2

Setting Description
1 1:Report destination level in 5s
2 2:Report 10 percent level while running

Technical Data

Hardware Platform SD3502
Device Type Window Covering - Pos/End Aware
Network Operation Always On Slave
Firmware Version HW: 1 FW: 1.04
Z-Wave Version 6.51.02
Certification ID ZC10-17055604
Z-Wave Product Id 0x0131.0x0001.0x0015
Firmware Updatable Updatable by Consumer by RF
Electric Load Type Incandescent
Neutral Wire Required ok
Supported Meter Type Electric Energy
Color White
Window Covering Control Features Endpoint AwareManual CalibrationPosition AwareSupports CurtainsSupports Up/Down Motion
Loads Controlled 2
Switch Type Push Button
Frequency XXfrequency
Maximum transmission power XXantenna
CEPT (Europe)Window Covering - Pos/End Aware