Quickstart

This is a secure On/Off Power Switch for XXXQFrequencyName. To run this device please connect it to your mains power supply. To add this device to your network execute the following action:
1. Put your Z-Wave controller into inclusion mode.2. Plug the SmatPlug into the power outlet.3. Press and hold on/off button about 5 seconds.4. Orange LED will be flashing about 2 seconds, then inclusion process will be start.5. Wait until inclusion will be done.



Important safety information

Please read this manual carefully. Failure to follow the recommendations in this manual may be dangerous or may violate the law. The manufacturer, importer, distributor and seller shall not be liable for any loss or damage resulting from failure to comply with the instructions in this manual or any other material. Use this equipment only for its intended purpose. Follow the disposal instructions. Do not dispose of electronic equipment or batteries in a fire or near open heat sources.
Attention: This manual is automatically generated from Z-Wave Alliance Product data and may be incomplete. Please refer to the Manufacturers Manual for more information.

Product Description

Smart- Plug plugs in between any appliance and the AC outlet.It measures its power consumption & sends that informationto your smartphone . It can also control power sourceconnected with appliance manually and remotely usingsmartphone.

Reset to factory default Please use this procedure only when the network primary controller is missing or otherwise inoperable.1. Plug the SmatPlug into the power outlet.2. Press and hold on/off button about 10 seconds.3. Orange LED will be flashing about 2 seconds, then factory reset process will be start.
Inclusion 1. Put your Z-Wave controller into inclusion mode.2. Plug the SmatPlug into the power outlet.3. Press and hold on/off button about 5 seconds.4. Orange LED will be flashing about 2 seconds, then inclusion process will be start.5. Wait until inclusion will be done.
Exclusion 1. Put your Z-Wave controller into exclusion mode2. Plug the SmatPlug into the power outlet.3. Press and hold on/off button about 5 seconds.4. Orange LED will be flashing about 2 seconds, then exclusion process will be start.5. Wait until exclusion will be done.
NIF XXXNIF
Wakeup XXXWakeupDescription
Protection XXXProtection
FirmwareUpdate XXXFirmwareUpdate
SetAssociation XXXSetAssociation

Association Groups:

Group Number Maximum Nodes Description
1 1 Z-Wave Plus LifelineThe following Z-Wave signals may be sent to the nodes in this group: NOTIFICATION_REPORT, METER_REPORT

Configuration Parameters

Parameter 1: standby power

First 3 Bytes : Standby Power Setting ValueLast 1 Byte : Standby Power Enable/DisableIf the value is set by 1000, standby power equals 10.00w (0x0003E8) andstandby power enable is 1.total 0x0003E801
Size: 4 Byte, Default Value: 0

Setting Description
0 standby power disable
257 - 524033 standby power enable with 0.01 to 20.47 W Standby

Parameter 2: meter transmit

Periodic Measurement Value Transmission Enable/Disable
Size: 1 Byte, Default Value: 1

Setting Description
1 Periodic Measurement Value Transmission Enable
0 Periodic Measurement Value Transmission Disable

Parameter 3: power accumulation mode

Power Accumulation Start/Stop
Size: 1 Byte, Default Value: 1

Setting Description
0 Power Accumulation Stop
1 Power Accumulation Start

Parameter 4: device usage

Connected Device Use / Not Use
Size: 1 Byte, Default Value: 0

Setting Description
1 Connected Device Use
0 Connected Device Not Use

Parameter 5: meter transmit interval

Periodic Measurement Value Transmission IntervalMinimum time interval : 10minutesValue : 1 (10minutes * 1) = 10minutes intervalValue : 2 (10minutes * 2) = 20minutes interval..Value : 127(10min * 72) = 720 minutes interval =>MAX
Size: 1 Byte, Default Value: 6

Setting Description
1 - 72 10min to 720 min

Technical Data

Hardware Platform ZM5101
Device Type On/Off Power Switch
Network Operation Always On Slave
Firmware Version HW: 1 FW: 39.128
Z-Wave Version 6.61.00
Certification ID ZC10-17055591
Z-Wave Product Id 0x0247.0x0042.0x0001
Supported Notification Types Power ManagementSystem
Switch Type Push Button
Supported Meter Type Electric Energy
Firmware Updatable Updatable by Professional/Technician
Frequency XXfrequency
Maximum transmission power XXantenna
South KoreaOn/Off Power Switch