This is a
Put the Z-WaveTM Interface Controller intoinclusion mode, and following its instruction to add the ZD2301 to your controller. To get in the inclusion mode, the distance between sensor and controller is suggested to be one meter. Press the program switch of ZD2301 for sending the NIF. After sending NIF, Z-Wave will send the auto inclusion; otherwise, ZD2301 will go to sleep after 20 seconds.
Z-Wave is the international wireless protocol for communication in the Smart Home. This device is suited for use in the region mentioned in the Quickstart section.
Z-Wave ensures a reliable communication by reconfirming every message (two-way communication) and every mains powered node can act as a repeater for other nodes (meshed network) in case the receiver is not in direct wireless range of the transmitter.
This device and every other certified Z-Wave device can be used together with any other certified Z-Wave device regardless of brand and origin as long as both are suited for the same frequency range.
If a device supports secure communication it will communicate with other devices secure as long as this device provides the same or a higher level of security. Otherwise it will automatically turn into a lower level of security to maintain backward compatibility.
For more information about Z-Wave technology, devices, white papers etc. please refer to www.z-wave.info.
Door/Window, humidity, temperature and luminance sensor. * Primarily used as dry contact door/window sensor.* Very low power consumption* LED indicator* Easy installation
Please read the user manual before installing the product.
In order to include (add) a Z-Wave device to a network it must be in factory default state. Please make sure to reset the device into factory default. You can do this by performing an Exclusion operation as described below in the manual. Every Z-Wave controller is able to perform this operation however it is recommended to use the primary controller of the previous network to make sure the very device is excluded properly from this network.
This device also allows to be reset without any involvement of a Z-Wave controller. This procedure should only be used when the primary controller is inoperable.
All user and network settings will be cleared and the device reset to factorydefaults when the device is excluded.Please use this procedure only in the event if the networkcontroller is missing or is otherwise inoperable.
On factory default the device does not belong to any Z-Wave network. The device needs to be added to an existing wireless network to communicate with the devices of this network. This process is called Inclusion.
Devices can also be removed from a network. This process is called Exclusion. Both processes are initiated by the primary controller of the Z-Wave network. This controller is turned into exclusion respective inclusion mode. Inclusion and Exclusion is then performed doing a special manual action right on the device.
This device is battery operated and turned into deep sleep state most of the time to save battery life time. Communication with the device is limited. In order to communicate with the device, a static controller C is needed in the network. This controller will maintain a mailbox for the battery operated devices and store commands that can not be received during deep sleep state. Without such a controller, communication may become impossible and/or the battery life time is significantly decreased.
This device will wakeup regularly and announce the wakeup state by sending out a so called Wakeup Notification. The controller can then empty the mailbox. Therefore, the device needs to be configured with the desired wakeup interval and the node ID of the controller. If the device was included by a static controller this controller will usually perform all necessary configurations. The wakeup interval is a tradeoff between maximal battery life time and the desired responses of the device. To wakeup the device please perform the following action: Press the Program SW, the LED will flash one time and ZD2301 will send Wake Up Notification after 5 seconds. If ZD2301 received Wake Up No More Information command then the ZD2301 will go to sleep or it will wait 10 seconds then go to sleep. It will precede all the commands after sending the Wake Up Notification
Here are a few hints for network installation if things dont work as expected.
Z-Wave devices control other Z-Wave devices. The relationship between one device controlling another device is called association. In order to control a different device, the controlling device needs to maintain a list of devices that will receive controlling commands. These lists are called association groups and they are always related to certain events (e.g. button pressed, sensor triggers, ...). In case the event happens all devices stored in the respective association group will receive the same wireless command wireless command, typically a 'Basic Set' Command.
Group Number | Maximum Nodes | Description |
---|---|---|
1 | 5 | Z-Wave Plus Lifeline |
Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can adapt the function better to user needs or unlock further enhanced features.
IMPORTANT: Controllers may only allow configuring signed values. In order to set values in the range 128 ... 255 the value sent in the application shall be the desired value minus 256. For example: To set a parameter to 200 it may be needed to set a value of 200 minus 256 = minus 56. In case of a two byte value the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Select the temperature report unit, Celsius or Fahrenheit Size: 1 Byte, Default Value: 0
Setting | Description |
---|---|
0 | Celsius |
0 - 1 | Fahrenheit |
Send temperature report when temperature changes by this amount. Size: 1 Byte, Default Value: 1
Setting | Description |
---|---|
1 - 50 | in 0.1 Celsius increments |
Send humidity report when humidity changes by this amount. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
1 - 50 | range from 1 to 50 percent |
Send luminance report when luminance changes by this amount. Size: 1 Byte, Default Value: 10
Setting | Description |
---|---|
0 - 50 | range from 0 to 50 percent |
Hardware Platform | ZM5202 |
Device Type | Notification Sensor |
Network Operation | Reporting Sleeping Slave |
Firmware Version | HW: 2 FW: 6.01:10.01 |
Z-Wave Version | 6.51.06 |
Certification ID | ZC10-17055583 |
Z-Wave Product Id | 0x0131.0x201F.0x1F20 |
Sensors | Air TemperatureHumidityLuminance |
Supported Notification Types | Access ControlHome Security |
Firmware Updatable | Updatable by Consumer by RF |
Color | White |
Frequency | XXfrequency |
Maximum transmission power | XXantenna |